Cargando…

Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study

BACKGROUND: New surgical techniques are developed to enable a quicker, easier and safer surgery with reduced risk of complications and shortened time needed for recovery. A resorbable device, a self-locking loop, was designed for surgical ligation. The objective of this pilot study was to investigat...

Descripción completa

Detalles Bibliográficos
Autores principales: Höglund, Odd V, Ingman, Jessica, Södersten, Fredrik, Hansson, Kerstin, Borg, Niklas, Lagerstedt, Anne-Sofie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247741/
https://www.ncbi.nlm.nih.gov/pubmed/25410023
http://dx.doi.org/10.1186/1756-0500-7-825
_version_ 1782346695246348288
author Höglund, Odd V
Ingman, Jessica
Södersten, Fredrik
Hansson, Kerstin
Borg, Niklas
Lagerstedt, Anne-Sofie
author_facet Höglund, Odd V
Ingman, Jessica
Södersten, Fredrik
Hansson, Kerstin
Borg, Niklas
Lagerstedt, Anne-Sofie
author_sort Höglund, Odd V
collection PubMed
description BACKGROUND: New surgical techniques are developed to enable a quicker, easier and safer surgery with reduced risk of complications and shortened time needed for recovery. A resorbable device, a self-locking loop, was designed for surgical ligation. The objective of this pilot study was to investigate the feasibility of ligating the spermatic cord with the device, its biocompatibility and long-term resorption in dogs. RESULTS: The device was made of a block co-polymer (glycolide and trimethylene carbonate), manufactured by injection moulding and consisted of a flexible band running through a case with a locking mechanism. Ten devices were tested for ligation of the spermatic cords in five dogs admitted for routine neutering. The dogs were monitored by physical examination and ultrasonography of the site of ligation, area of spermatic cord and medial iliac lymph nodes regularly until no hyperechoic remnants of the device or acoustic shadowing or local tissue reactions were observed. Haemostasis of the spermatic cords was achieved with the devices. On ultrasonography the devices were seen as hyperechoic structures for 2 months after neutering causing acoustic shadowing for 1 month. The dogs were monitored for 3 – 5 months after surgery. Gradual decrease in echogenicity and final disappearance of the hyperechoic structures suggested resorption. Macroscopic and histological post mortem examinations were performed in one dog at 3 months after surgery. Post mortem examination showed a tissue reaction of a suture granuloma that was restricted in extent at site of the device. CONCLUSIONS: The results of this pilot study suggest biocompatibility and indicate that ligation of the spermatic cord is feasible with the device.
format Online
Article
Text
id pubmed-4247741
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42477412014-11-30 Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study Höglund, Odd V Ingman, Jessica Södersten, Fredrik Hansson, Kerstin Borg, Niklas Lagerstedt, Anne-Sofie BMC Res Notes Research Article BACKGROUND: New surgical techniques are developed to enable a quicker, easier and safer surgery with reduced risk of complications and shortened time needed for recovery. A resorbable device, a self-locking loop, was designed for surgical ligation. The objective of this pilot study was to investigate the feasibility of ligating the spermatic cord with the device, its biocompatibility and long-term resorption in dogs. RESULTS: The device was made of a block co-polymer (glycolide and trimethylene carbonate), manufactured by injection moulding and consisted of a flexible band running through a case with a locking mechanism. Ten devices were tested for ligation of the spermatic cords in five dogs admitted for routine neutering. The dogs were monitored by physical examination and ultrasonography of the site of ligation, area of spermatic cord and medial iliac lymph nodes regularly until no hyperechoic remnants of the device or acoustic shadowing or local tissue reactions were observed. Haemostasis of the spermatic cords was achieved with the devices. On ultrasonography the devices were seen as hyperechoic structures for 2 months after neutering causing acoustic shadowing for 1 month. The dogs were monitored for 3 – 5 months after surgery. Gradual decrease in echogenicity and final disappearance of the hyperechoic structures suggested resorption. Macroscopic and histological post mortem examinations were performed in one dog at 3 months after surgery. Post mortem examination showed a tissue reaction of a suture granuloma that was restricted in extent at site of the device. CONCLUSIONS: The results of this pilot study suggest biocompatibility and indicate that ligation of the spermatic cord is feasible with the device. BioMed Central 2014-11-20 /pmc/articles/PMC4247741/ /pubmed/25410023 http://dx.doi.org/10.1186/1756-0500-7-825 Text en © Höglund et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Höglund, Odd V
Ingman, Jessica
Södersten, Fredrik
Hansson, Kerstin
Borg, Niklas
Lagerstedt, Anne-Sofie
Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study
title Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study
title_full Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study
title_fullStr Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study
title_full_unstemmed Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study
title_short Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study
title_sort ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer – feasibility and long-term follow-up study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247741/
https://www.ncbi.nlm.nih.gov/pubmed/25410023
http://dx.doi.org/10.1186/1756-0500-7-825
work_keys_str_mv AT hoglundoddv ligationofthespermaticcordindogswithaselflockingdeviceofaresorbablepolyglycolicbasedcopolymerfeasibilityandlongtermfollowupstudy
AT ingmanjessica ligationofthespermaticcordindogswithaselflockingdeviceofaresorbablepolyglycolicbasedcopolymerfeasibilityandlongtermfollowupstudy
AT soderstenfredrik ligationofthespermaticcordindogswithaselflockingdeviceofaresorbablepolyglycolicbasedcopolymerfeasibilityandlongtermfollowupstudy
AT hanssonkerstin ligationofthespermaticcordindogswithaselflockingdeviceofaresorbablepolyglycolicbasedcopolymerfeasibilityandlongtermfollowupstudy
AT borgniklas ligationofthespermaticcordindogswithaselflockingdeviceofaresorbablepolyglycolicbasedcopolymerfeasibilityandlongtermfollowupstudy
AT lagerstedtannesofie ligationofthespermaticcordindogswithaselflockingdeviceofaresorbablepolyglycolicbasedcopolymerfeasibilityandlongtermfollowupstudy