Cargando…

Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study

BACKGROUND: Treatment of lateral fractures of the clavicle is challenging and has been controversially discussed for a long time due to high non-union rates in non-operative treatment and high complication rates in surgical treatment. Acromioclavicular joint instability due to the injury of the clos...

Descripción completa

Detalles Bibliográficos
Autores principales: Beirer, Marc, Siebenlist, Sebastian, Crönlein, Moritz, Postl, Lukas, Huber-Wagner, Stefan, Biberthaler, Peter, Kirchhoff, Chlodwig
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247764/
https://www.ncbi.nlm.nih.gov/pubmed/25406639
http://dx.doi.org/10.1186/1471-2474-15-380
_version_ 1782346700125372416
author Beirer, Marc
Siebenlist, Sebastian
Crönlein, Moritz
Postl, Lukas
Huber-Wagner, Stefan
Biberthaler, Peter
Kirchhoff, Chlodwig
author_facet Beirer, Marc
Siebenlist, Sebastian
Crönlein, Moritz
Postl, Lukas
Huber-Wagner, Stefan
Biberthaler, Peter
Kirchhoff, Chlodwig
author_sort Beirer, Marc
collection PubMed
description BACKGROUND: Treatment of lateral fractures of the clavicle is challenging and has been controversially discussed for a long time due to high non-union rates in non-operative treatment and high complication rates in surgical treatment. Acromioclavicular joint instability due to the injury of the closely neighbored coraco-clavicular ligaments can result in a cranialization of the medial clavicle shaft. A recently developed implant showed a promising functional outcome in a small collective of patients. METHODS: In this prospective study, 20 patients with a mean age of 40.7 ± 11.3 years with a dislocated fracture of the lateral clavicle (Jäger&Breitner I-III, Neer I-III) were enrolled. All patients were surgically treated using the locking compression plate (LCP) for the superior anterior clavicle (Synthes®). Functional outcome was recorded using the Munich Shoulder Questionnaire (MSQ) allowing for qualitative self-assessment of the Shoulder Pain and Disability Index (SPADI), of the Disability of the Arm, Shoulder and Hand (DASH) score and of the Constant Score. Acromioclavicular joint stability was evaluated using the Taft-Score. RESULTS: The mean follow-up was 14.2 ± 4.0 months. The mean MSQ was 87.0 ± 7.4 points, the mean SPADI 91.1 ± 11.3 points, the mean DASH score 7.6 ± 7.3 points and the mean normative age- and sex-specific Constant Score 85.6 ± 8.0 points. The mean Taft Score resulted in 10.7 ± 1.0 points. The mean Taft Score in lateral clavicular fractures with fracture gap between the coracoclavicular ligaments in combination with a rupture of the conoid ligament (J&B II a, Neer II B; n =11) was with 10.3 ± 0.9 points significantly lower than the mean Taft Score of all other types of lateral clavicle fractures (J&B I, II b, III; n =9) which resulted in 11.3 ± 0.9 points (p < 0.05). CONCLUSIONS: The Synthes® LCP superior anterior clavicle plate allows for a safe stabilization and good functional outcome with high patient satisfaction in fractures of the lateral clavicle. However, in fractures type Jäger&Breitner II a, Neer II B a significant acromioclavicular joint instability was observed and additional reconstruction of the coracoclavicular ligaments should be performed. TRIAL REGISTRATION: ClinicalTrials.gov NCT02256059. Registered 02 October 2014. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/1471-2474-15-380) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4247764
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42477642014-11-30 Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study Beirer, Marc Siebenlist, Sebastian Crönlein, Moritz Postl, Lukas Huber-Wagner, Stefan Biberthaler, Peter Kirchhoff, Chlodwig BMC Musculoskelet Disord Research Article BACKGROUND: Treatment of lateral fractures of the clavicle is challenging and has been controversially discussed for a long time due to high non-union rates in non-operative treatment and high complication rates in surgical treatment. Acromioclavicular joint instability due to the injury of the closely neighbored coraco-clavicular ligaments can result in a cranialization of the medial clavicle shaft. A recently developed implant showed a promising functional outcome in a small collective of patients. METHODS: In this prospective study, 20 patients with a mean age of 40.7 ± 11.3 years with a dislocated fracture of the lateral clavicle (Jäger&Breitner I-III, Neer I-III) were enrolled. All patients were surgically treated using the locking compression plate (LCP) for the superior anterior clavicle (Synthes®). Functional outcome was recorded using the Munich Shoulder Questionnaire (MSQ) allowing for qualitative self-assessment of the Shoulder Pain and Disability Index (SPADI), of the Disability of the Arm, Shoulder and Hand (DASH) score and of the Constant Score. Acromioclavicular joint stability was evaluated using the Taft-Score. RESULTS: The mean follow-up was 14.2 ± 4.0 months. The mean MSQ was 87.0 ± 7.4 points, the mean SPADI 91.1 ± 11.3 points, the mean DASH score 7.6 ± 7.3 points and the mean normative age- and sex-specific Constant Score 85.6 ± 8.0 points. The mean Taft Score resulted in 10.7 ± 1.0 points. The mean Taft Score in lateral clavicular fractures with fracture gap between the coracoclavicular ligaments in combination with a rupture of the conoid ligament (J&B II a, Neer II B; n =11) was with 10.3 ± 0.9 points significantly lower than the mean Taft Score of all other types of lateral clavicle fractures (J&B I, II b, III; n =9) which resulted in 11.3 ± 0.9 points (p < 0.05). CONCLUSIONS: The Synthes® LCP superior anterior clavicle plate allows for a safe stabilization and good functional outcome with high patient satisfaction in fractures of the lateral clavicle. However, in fractures type Jäger&Breitner II a, Neer II B a significant acromioclavicular joint instability was observed and additional reconstruction of the coracoclavicular ligaments should be performed. TRIAL REGISTRATION: ClinicalTrials.gov NCT02256059. Registered 02 October 2014. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/1471-2474-15-380) contains supplementary material, which is available to authorized users. BioMed Central 2014-11-19 /pmc/articles/PMC4247764/ /pubmed/25406639 http://dx.doi.org/10.1186/1471-2474-15-380 Text en © Beirer et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Beirer, Marc
Siebenlist, Sebastian
Crönlein, Moritz
Postl, Lukas
Huber-Wagner, Stefan
Biberthaler, Peter
Kirchhoff, Chlodwig
Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
title Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
title_full Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
title_fullStr Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
title_full_unstemmed Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
title_short Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
title_sort clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247764/
https://www.ncbi.nlm.nih.gov/pubmed/25406639
http://dx.doi.org/10.1186/1471-2474-15-380
work_keys_str_mv AT beirermarc clinicalandradiologicaloutcomefollowingtreatmentofdisplacedlateralclaviclefracturesusingalockingcompressionplatewithlateralextensionaprospectivestudy
AT siebenlistsebastian clinicalandradiologicaloutcomefollowingtreatmentofdisplacedlateralclaviclefracturesusingalockingcompressionplatewithlateralextensionaprospectivestudy
AT cronleinmoritz clinicalandradiologicaloutcomefollowingtreatmentofdisplacedlateralclaviclefracturesusingalockingcompressionplatewithlateralextensionaprospectivestudy
AT postllukas clinicalandradiologicaloutcomefollowingtreatmentofdisplacedlateralclaviclefracturesusingalockingcompressionplatewithlateralextensionaprospectivestudy
AT huberwagnerstefan clinicalandradiologicaloutcomefollowingtreatmentofdisplacedlateralclaviclefracturesusingalockingcompressionplatewithlateralextensionaprospectivestudy
AT biberthalerpeter clinicalandradiologicaloutcomefollowingtreatmentofdisplacedlateralclaviclefracturesusingalockingcompressionplatewithlateralextensionaprospectivestudy
AT kirchhoffchlodwig clinicalandradiologicaloutcomefollowingtreatmentofdisplacedlateralclaviclefracturesusingalockingcompressionplatewithlateralextensionaprospectivestudy