Cargando…

Maintaining Oxygenation Successfully with High Flow Nasal Cannula during Diagnostic Bronchoscopy on a Postoperative Lung Transplant Patient in the Intensive Care

Bronchoscopy is an important diagnostic and therapeutic intervention for a variety of patients displaying pulmonary pathology. The heterogeneity of the patients undergoing bronchoscopy affords a challenge for providing minimal and safe respiratory support during anesthesia. Currently, options are in...

Descripción completa

Detalles Bibliográficos
Autores principales: Diab, Sara, Fraser, John F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247916/
https://www.ncbi.nlm.nih.gov/pubmed/25478241
http://dx.doi.org/10.1155/2014/198262
_version_ 1782346722905686016
author Diab, Sara
Fraser, John F.
author_facet Diab, Sara
Fraser, John F.
author_sort Diab, Sara
collection PubMed
description Bronchoscopy is an important diagnostic and therapeutic intervention for a variety of patients displaying pulmonary pathology. The heterogeneity of the patients undergoing bronchoscopy affords a challenge for providing minimal and safe respiratory support during anesthesia. Currently, options are intubation and general anesthesia versus frequently inadequate sedation or local anaesthesia with low flow oxygen through nasal prongs or mouthpiece. The advent of high flow nasal cannula allows the clinician to have a “middle man” that allows high flow oxygen delivery as well as a degree of respiratory support, which in some cases has been noted to be between 3 and 4 cm of continuous positive airway pressure-like effect. There are minimal data analyzing the use of high flow nasal cannula during anesthesia for bronchoscopy. We present a case report of orthotropic lung transplant recipient undergoing diagnostic bronchoscopy whilst being supported with high flow nasal oxygen in the intensive care unit.
format Online
Article
Text
id pubmed-4247916
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-42479162014-12-04 Maintaining Oxygenation Successfully with High Flow Nasal Cannula during Diagnostic Bronchoscopy on a Postoperative Lung Transplant Patient in the Intensive Care Diab, Sara Fraser, John F. Case Rep Crit Care Case Report Bronchoscopy is an important diagnostic and therapeutic intervention for a variety of patients displaying pulmonary pathology. The heterogeneity of the patients undergoing bronchoscopy affords a challenge for providing minimal and safe respiratory support during anesthesia. Currently, options are intubation and general anesthesia versus frequently inadequate sedation or local anaesthesia with low flow oxygen through nasal prongs or mouthpiece. The advent of high flow nasal cannula allows the clinician to have a “middle man” that allows high flow oxygen delivery as well as a degree of respiratory support, which in some cases has been noted to be between 3 and 4 cm of continuous positive airway pressure-like effect. There are minimal data analyzing the use of high flow nasal cannula during anesthesia for bronchoscopy. We present a case report of orthotropic lung transplant recipient undergoing diagnostic bronchoscopy whilst being supported with high flow nasal oxygen in the intensive care unit. Hindawi Publishing Corporation 2014 2014-11-13 /pmc/articles/PMC4247916/ /pubmed/25478241 http://dx.doi.org/10.1155/2014/198262 Text en Copyright © 2014 S. Diab and J. F. Fraser. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Diab, Sara
Fraser, John F.
Maintaining Oxygenation Successfully with High Flow Nasal Cannula during Diagnostic Bronchoscopy on a Postoperative Lung Transplant Patient in the Intensive Care
title Maintaining Oxygenation Successfully with High Flow Nasal Cannula during Diagnostic Bronchoscopy on a Postoperative Lung Transplant Patient in the Intensive Care
title_full Maintaining Oxygenation Successfully with High Flow Nasal Cannula during Diagnostic Bronchoscopy on a Postoperative Lung Transplant Patient in the Intensive Care
title_fullStr Maintaining Oxygenation Successfully with High Flow Nasal Cannula during Diagnostic Bronchoscopy on a Postoperative Lung Transplant Patient in the Intensive Care
title_full_unstemmed Maintaining Oxygenation Successfully with High Flow Nasal Cannula during Diagnostic Bronchoscopy on a Postoperative Lung Transplant Patient in the Intensive Care
title_short Maintaining Oxygenation Successfully with High Flow Nasal Cannula during Diagnostic Bronchoscopy on a Postoperative Lung Transplant Patient in the Intensive Care
title_sort maintaining oxygenation successfully with high flow nasal cannula during diagnostic bronchoscopy on a postoperative lung transplant patient in the intensive care
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247916/
https://www.ncbi.nlm.nih.gov/pubmed/25478241
http://dx.doi.org/10.1155/2014/198262
work_keys_str_mv AT diabsara maintainingoxygenationsuccessfullywithhighflownasalcannuladuringdiagnosticbronchoscopyonapostoperativelungtransplantpatientintheintensivecare
AT fraserjohnf maintainingoxygenationsuccessfullywithhighflownasalcannuladuringdiagnosticbronchoscopyonapostoperativelungtransplantpatientintheintensivecare