Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols

OBJECTIVE: To compare the image quality of shoulder CT arthrography performed using 120 kVp and 140 kVp protocols. MATERIALS AND METHODS: Fifty-four CT examinations were prospectively included. CT scans were performed on each patient at 120 kVp and 140 kVp; other scanning parameters were kept consta...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahn, Se Jin, Hong, Sung Hwan, Chai, Jee Won, Choi, Ja-Young, Yoo, Hye Jin, Kim, Sae Hoon, Kang, Heung Sik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4248629/
https://www.ncbi.nlm.nih.gov/pubmed/25469085
http://dx.doi.org/10.3348/kjr.2014.15.6.739
_version_ 1782346838588784640
author Ahn, Se Jin
Hong, Sung Hwan
Chai, Jee Won
Choi, Ja-Young
Yoo, Hye Jin
Kim, Sae Hoon
Kang, Heung Sik
author_facet Ahn, Se Jin
Hong, Sung Hwan
Chai, Jee Won
Choi, Ja-Young
Yoo, Hye Jin
Kim, Sae Hoon
Kang, Heung Sik
author_sort Ahn, Se Jin
collection PubMed
description OBJECTIVE: To compare the image quality of shoulder CT arthrography performed using 120 kVp and 140 kVp protocols. MATERIALS AND METHODS: Fifty-four CT examinations were prospectively included. CT scans were performed on each patient at 120 kVp and 140 kVp; other scanning parameters were kept constant. Image qualities were qualitatively and quantitatively compared with respect to noise, contrast, and diagnostic acceptability. Diagnostic acceptabilities were graded using a one to five scale as follows: 1, suboptimal; 2, below average; 3, acceptable; 4, above average; and 5, superior. Radiation doses were also compared. RESULTS: Contrast was better at 120 kVp, but noise was greater. No significant differences were observed between the 120 kVp and 140 kVp protocols in terms of diagnostic acceptability, signal-to-noise ratio, or contrast-to-noise ratio. Lowering tube voltage from 140 kVp to 120 kVp reduced the radiation dose by 33%. CONCLUSION: The use of 120 kVp during shoulder CT arthrography reduces radiation dose versus 140 kVp without significant loss of image quality.
format Online
Article
Text
id pubmed-4248629
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-42486292014-12-02 Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols Ahn, Se Jin Hong, Sung Hwan Chai, Jee Won Choi, Ja-Young Yoo, Hye Jin Kim, Sae Hoon Kang, Heung Sik Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To compare the image quality of shoulder CT arthrography performed using 120 kVp and 140 kVp protocols. MATERIALS AND METHODS: Fifty-four CT examinations were prospectively included. CT scans were performed on each patient at 120 kVp and 140 kVp; other scanning parameters were kept constant. Image qualities were qualitatively and quantitatively compared with respect to noise, contrast, and diagnostic acceptability. Diagnostic acceptabilities were graded using a one to five scale as follows: 1, suboptimal; 2, below average; 3, acceptable; 4, above average; and 5, superior. Radiation doses were also compared. RESULTS: Contrast was better at 120 kVp, but noise was greater. No significant differences were observed between the 120 kVp and 140 kVp protocols in terms of diagnostic acceptability, signal-to-noise ratio, or contrast-to-noise ratio. Lowering tube voltage from 140 kVp to 120 kVp reduced the radiation dose by 33%. CONCLUSION: The use of 120 kVp during shoulder CT arthrography reduces radiation dose versus 140 kVp without significant loss of image quality. The Korean Society of Radiology 2014 2014-11-07 /pmc/articles/PMC4248629/ /pubmed/25469085 http://dx.doi.org/10.3348/kjr.2014.15.6.739 Text en Copyright © 2014 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Musculoskeletal Imaging
Ahn, Se Jin
Hong, Sung Hwan
Chai, Jee Won
Choi, Ja-Young
Yoo, Hye Jin
Kim, Sae Hoon
Kang, Heung Sik
Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols
title Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols
title_full Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols
title_fullStr Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols
title_full_unstemmed Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols
title_short Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols
title_sort comparison of image quality of shoulder ct arthrography conducted using 120 kvp and 140 kvp protocols
topic Musculoskeletal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4248629/
https://www.ncbi.nlm.nih.gov/pubmed/25469085
http://dx.doi.org/10.3348/kjr.2014.15.6.739
work_keys_str_mv AT ahnsejin comparisonofimagequalityofshoulderctarthrographyconductedusing120kvpand140kvpprotocols
AT hongsunghwan comparisonofimagequalityofshoulderctarthrographyconductedusing120kvpand140kvpprotocols
AT chaijeewon comparisonofimagequalityofshoulderctarthrographyconductedusing120kvpand140kvpprotocols
AT choijayoung comparisonofimagequalityofshoulderctarthrographyconductedusing120kvpand140kvpprotocols
AT yoohyejin comparisonofimagequalityofshoulderctarthrographyconductedusing120kvpand140kvpprotocols
AT kimsaehoon comparisonofimagequalityofshoulderctarthrographyconductedusing120kvpand140kvpprotocols
AT kangheungsik comparisonofimagequalityofshoulderctarthrographyconductedusing120kvpand140kvpprotocols