Cargando…
Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
OBJECTIVE: To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. MATERIALS AND METHODS: Dual-energy scans with monochromatic spectral imaging mode an...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4248630/ https://www.ncbi.nlm.nih.gov/pubmed/25469086 http://dx.doi.org/10.3348/kjr.2014.15.6.746 |
_version_ | 1782346838821568512 |
---|---|
author | An, Chansik Chun, Yong-Min Kim, Sungjun Lee, Young Han Yun, Min Jeong Suh, Jin-Suck Song, Ho-Taek |
author_facet | An, Chansik Chun, Yong-Min Kim, Sungjun Lee, Young Han Yun, Min Jeong Suh, Jin-Suck Song, Ho-Taek |
author_sort | An, Chansik |
collection | PubMed |
description | OBJECTIVE: To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. MATERIALS AND METHODS: Dual-energy scans with monochromatic spectral imaging mode and conventional single energy scans were performed on a shoulder phantom with 10 concentrations from 0 to 210 mg/mL of iodinated contrast medium at intervals of 15 or 30 mg/mL. Image noise, tissue contrast, and beam hardening artifacts were assessed to determine the optimum dose of contrast agent and the level of monochromatic energy for DECT shoulder arthrography in terms of the lowest image noise and the least beam hardening artifacts while good tissue contrast was maintained. Material decomposition (MD) imaging for bone-iodine differentiation was qualitatively assessed. The optimized protocol was applied and evaluated in 23 patients. RESULTS: The optimal contrast dose and energy level were determined by the phantom study at 60 mg/mL and 72 keV, respectively. This optimized protocol for human study reduced the image noise and the beam-hardening artifacts by 35.9% and 44.5%, respectively. Bone-iodine differentiation by MD imaging was not affected by the iodine concentration or level of energy. CONCLUSION: Dual-energy scan with monochromatic spectral imaging mode results in reduced image noise and beam hardening artifacts. |
format | Online Article Text |
id | pubmed-4248630 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-42486302014-12-02 Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level An, Chansik Chun, Yong-Min Kim, Sungjun Lee, Young Han Yun, Min Jeong Suh, Jin-Suck Song, Ho-Taek Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. MATERIALS AND METHODS: Dual-energy scans with monochromatic spectral imaging mode and conventional single energy scans were performed on a shoulder phantom with 10 concentrations from 0 to 210 mg/mL of iodinated contrast medium at intervals of 15 or 30 mg/mL. Image noise, tissue contrast, and beam hardening artifacts were assessed to determine the optimum dose of contrast agent and the level of monochromatic energy for DECT shoulder arthrography in terms of the lowest image noise and the least beam hardening artifacts while good tissue contrast was maintained. Material decomposition (MD) imaging for bone-iodine differentiation was qualitatively assessed. The optimized protocol was applied and evaluated in 23 patients. RESULTS: The optimal contrast dose and energy level were determined by the phantom study at 60 mg/mL and 72 keV, respectively. This optimized protocol for human study reduced the image noise and the beam-hardening artifacts by 35.9% and 44.5%, respectively. Bone-iodine differentiation by MD imaging was not affected by the iodine concentration or level of energy. CONCLUSION: Dual-energy scan with monochromatic spectral imaging mode results in reduced image noise and beam hardening artifacts. The Korean Society of Radiology 2014 2014-11-07 /pmc/articles/PMC4248630/ /pubmed/25469086 http://dx.doi.org/10.3348/kjr.2014.15.6.746 Text en Copyright © 2014 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Musculoskeletal Imaging An, Chansik Chun, Yong-Min Kim, Sungjun Lee, Young Han Yun, Min Jeong Suh, Jin-Suck Song, Ho-Taek Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level |
title | Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level |
title_full | Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level |
title_fullStr | Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level |
title_full_unstemmed | Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level |
title_short | Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level |
title_sort | dual-energy computed tomography arthrography of the shoulder joint using virtual monochromatic spectral imaging: optimal dose of contrast agent and monochromatic energy level |
topic | Musculoskeletal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4248630/ https://www.ncbi.nlm.nih.gov/pubmed/25469086 http://dx.doi.org/10.3348/kjr.2014.15.6.746 |
work_keys_str_mv | AT anchansik dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel AT chunyongmin dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel AT kimsungjun dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel AT leeyounghan dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel AT yunminjeong dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel AT suhjinsuck dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel AT songhotaek dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel |