Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level

OBJECTIVE: To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. MATERIALS AND METHODS: Dual-energy scans with monochromatic spectral imaging mode an...

Descripción completa

Detalles Bibliográficos
Autores principales: An, Chansik, Chun, Yong-Min, Kim, Sungjun, Lee, Young Han, Yun, Min Jeong, Suh, Jin-Suck, Song, Ho-Taek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4248630/
https://www.ncbi.nlm.nih.gov/pubmed/25469086
http://dx.doi.org/10.3348/kjr.2014.15.6.746
_version_ 1782346838821568512
author An, Chansik
Chun, Yong-Min
Kim, Sungjun
Lee, Young Han
Yun, Min Jeong
Suh, Jin-Suck
Song, Ho-Taek
author_facet An, Chansik
Chun, Yong-Min
Kim, Sungjun
Lee, Young Han
Yun, Min Jeong
Suh, Jin-Suck
Song, Ho-Taek
author_sort An, Chansik
collection PubMed
description OBJECTIVE: To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. MATERIALS AND METHODS: Dual-energy scans with monochromatic spectral imaging mode and conventional single energy scans were performed on a shoulder phantom with 10 concentrations from 0 to 210 mg/mL of iodinated contrast medium at intervals of 15 or 30 mg/mL. Image noise, tissue contrast, and beam hardening artifacts were assessed to determine the optimum dose of contrast agent and the level of monochromatic energy for DECT shoulder arthrography in terms of the lowest image noise and the least beam hardening artifacts while good tissue contrast was maintained. Material decomposition (MD) imaging for bone-iodine differentiation was qualitatively assessed. The optimized protocol was applied and evaluated in 23 patients. RESULTS: The optimal contrast dose and energy level were determined by the phantom study at 60 mg/mL and 72 keV, respectively. This optimized protocol for human study reduced the image noise and the beam-hardening artifacts by 35.9% and 44.5%, respectively. Bone-iodine differentiation by MD imaging was not affected by the iodine concentration or level of energy. CONCLUSION: Dual-energy scan with monochromatic spectral imaging mode results in reduced image noise and beam hardening artifacts.
format Online
Article
Text
id pubmed-4248630
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-42486302014-12-02 Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level An, Chansik Chun, Yong-Min Kim, Sungjun Lee, Young Han Yun, Min Jeong Suh, Jin-Suck Song, Ho-Taek Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. MATERIALS AND METHODS: Dual-energy scans with monochromatic spectral imaging mode and conventional single energy scans were performed on a shoulder phantom with 10 concentrations from 0 to 210 mg/mL of iodinated contrast medium at intervals of 15 or 30 mg/mL. Image noise, tissue contrast, and beam hardening artifacts were assessed to determine the optimum dose of contrast agent and the level of monochromatic energy for DECT shoulder arthrography in terms of the lowest image noise and the least beam hardening artifacts while good tissue contrast was maintained. Material decomposition (MD) imaging for bone-iodine differentiation was qualitatively assessed. The optimized protocol was applied and evaluated in 23 patients. RESULTS: The optimal contrast dose and energy level were determined by the phantom study at 60 mg/mL and 72 keV, respectively. This optimized protocol for human study reduced the image noise and the beam-hardening artifacts by 35.9% and 44.5%, respectively. Bone-iodine differentiation by MD imaging was not affected by the iodine concentration or level of energy. CONCLUSION: Dual-energy scan with monochromatic spectral imaging mode results in reduced image noise and beam hardening artifacts. The Korean Society of Radiology 2014 2014-11-07 /pmc/articles/PMC4248630/ /pubmed/25469086 http://dx.doi.org/10.3348/kjr.2014.15.6.746 Text en Copyright © 2014 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Musculoskeletal Imaging
An, Chansik
Chun, Yong-Min
Kim, Sungjun
Lee, Young Han
Yun, Min Jeong
Suh, Jin-Suck
Song, Ho-Taek
Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
title Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
title_full Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
title_fullStr Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
title_full_unstemmed Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
title_short Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
title_sort dual-energy computed tomography arthrography of the shoulder joint using virtual monochromatic spectral imaging: optimal dose of contrast agent and monochromatic energy level
topic Musculoskeletal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4248630/
https://www.ncbi.nlm.nih.gov/pubmed/25469086
http://dx.doi.org/10.3348/kjr.2014.15.6.746
work_keys_str_mv AT anchansik dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel
AT chunyongmin dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel
AT kimsungjun dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel
AT leeyounghan dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel
AT yunminjeong dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel
AT suhjinsuck dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel
AT songhotaek dualenergycomputedtomographyarthrographyoftheshoulderjointusingvirtualmonochromaticspectralimagingoptimaldoseofcontrastagentandmonochromaticenergylevel