Cargando…

Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center

OBJECTIVE: To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. MATERIALS AND METHODS: We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331...

Descripción completa

Detalles Bibliográficos
Autores principales: Chun, Chang Woo, Kim, Bum-Soo, Lee, Cheol Hyoun, Ihn, Yon Kwon, Shin, Yong-Sam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4248642/
https://www.ncbi.nlm.nih.gov/pubmed/25469098
http://dx.doi.org/10.3348/kjr.2014.15.6.844
_version_ 1782346841679986688
author Chun, Chang Woo
Kim, Bum-Soo
Lee, Cheol Hyoun
Ihn, Yon Kwon
Shin, Yong-Sam
author_facet Chun, Chang Woo
Kim, Bum-Soo
Lee, Cheol Hyoun
Ihn, Yon Kwon
Shin, Yong-Sam
author_sort Chun, Chang Woo
collection PubMed
description OBJECTIVE: To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. MATERIALS AND METHODS: We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. RESULTS: Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 ± 44.8 Gy-cm(2), and 251 ± 49 frames for diagnostic procedures, 52.9 minutes, 226.0 ± 129.2 Gy-cm(2), and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 ± 184.6 Gy-cm(2), and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm(2) for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 ± 3.2 Gy-cm(2). On average, rotational angiography was used 1.4 ± 0.6 times/session (range, 1-4; n = 580). CONCLUSION: Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level.
format Online
Article
Text
id pubmed-4248642
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-42486422014-12-02 Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center Chun, Chang Woo Kim, Bum-Soo Lee, Cheol Hyoun Ihn, Yon Kwon Shin, Yong-Sam Korean J Radiol Neurointervention OBJECTIVE: To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. MATERIALS AND METHODS: We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. RESULTS: Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 ± 44.8 Gy-cm(2), and 251 ± 49 frames for diagnostic procedures, 52.9 minutes, 226.0 ± 129.2 Gy-cm(2), and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 ± 184.6 Gy-cm(2), and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm(2) for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 ± 3.2 Gy-cm(2). On average, rotational angiography was used 1.4 ± 0.6 times/session (range, 1-4; n = 580). CONCLUSION: Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level. The Korean Society of Radiology 2014 2014-11-07 /pmc/articles/PMC4248642/ /pubmed/25469098 http://dx.doi.org/10.3348/kjr.2014.15.6.844 Text en Copyright © 2014 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Neurointervention
Chun, Chang Woo
Kim, Bum-Soo
Lee, Cheol Hyoun
Ihn, Yon Kwon
Shin, Yong-Sam
Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center
title Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center
title_full Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center
title_fullStr Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center
title_full_unstemmed Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center
title_short Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center
title_sort patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: experience at a single center
topic Neurointervention
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4248642/
https://www.ncbi.nlm.nih.gov/pubmed/25469098
http://dx.doi.org/10.3348/kjr.2014.15.6.844
work_keys_str_mv AT chunchangwoo patientradiationdoseindiagnosticandinterventionalproceduresforintracranialaneurysmsexperienceatasinglecenter
AT kimbumsoo patientradiationdoseindiagnosticandinterventionalproceduresforintracranialaneurysmsexperienceatasinglecenter
AT leecheolhyoun patientradiationdoseindiagnosticandinterventionalproceduresforintracranialaneurysmsexperienceatasinglecenter
AT ihnyonkwon patientradiationdoseindiagnosticandinterventionalproceduresforintracranialaneurysmsexperienceatasinglecenter
AT shinyongsam patientradiationdoseindiagnosticandinterventionalproceduresforintracranialaneurysmsexperienceatasinglecenter