Cargando…

A Laboratory Based Investigation of a New Elastic Toothbrush Head

Purpose. To demonstrate the noninferiority of a new toothbrush head with retractile bristles compared to traditional toothbrush heads on dental models. Methods. The new toothbrush head, mounted on manual and electrical handles, presents retractile bristle groups that can singularly retract over its...

Descripción completa

Detalles Bibliográficos
Autores principales: Mazza, Lorenzo, Gatto, Maria Rosaria, Monaco, Giuseppe, Pelliccioni, Gian Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4251081/
https://www.ncbi.nlm.nih.gov/pubmed/25485301
http://dx.doi.org/10.1155/2014/763968
_version_ 1782347001968459776
author Mazza, Lorenzo
Gatto, Maria Rosaria
Monaco, Giuseppe
Pelliccioni, Gian Andrea
author_facet Mazza, Lorenzo
Gatto, Maria Rosaria
Monaco, Giuseppe
Pelliccioni, Gian Andrea
author_sort Mazza, Lorenzo
collection PubMed
description Purpose. To demonstrate the noninferiority of a new toothbrush head with retractile bristles compared to traditional toothbrush heads on dental models. Methods. The new toothbrush head, mounted on manual and electrical handles, presents retractile bristle groups that can singularly retract over its entire length and offer calibrated resistance. Fourteen gypsum models of dental arches, twelve with and two without anatomical impairments, were spread with a “plaque simulator.” Each arch was brushed twice with each of the four toothbrushes, one minute by the same operator, blinded to the study. The plaque index (PI) was recorded at the end of each brushing session. GLM for repeated measures analysed the data. Results. On all the casts, the manual prototype and the electric prototype, removed 11% and 14% more “plaque simulator” compared to the standard toothbrush. In presence of dental anomalies, the prototypes removed 13% and 16% more plaque, respectively, compared to standard toothbrushes (P = 0.04). In both situations, the 95% confidence intervals of PI did not include −10% (the minimal margin of clinical relevance). Conclusions. The prototype is more effective in removing plaque from the casts with anomalies. The noninferiority of the prototype with respect to the standard toothbrushes was demonstrated.
format Online
Article
Text
id pubmed-4251081
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-42510812014-12-07 A Laboratory Based Investigation of a New Elastic Toothbrush Head Mazza, Lorenzo Gatto, Maria Rosaria Monaco, Giuseppe Pelliccioni, Gian Andrea ScientificWorldJournal Research Article Purpose. To demonstrate the noninferiority of a new toothbrush head with retractile bristles compared to traditional toothbrush heads on dental models. Methods. The new toothbrush head, mounted on manual and electrical handles, presents retractile bristle groups that can singularly retract over its entire length and offer calibrated resistance. Fourteen gypsum models of dental arches, twelve with and two without anatomical impairments, were spread with a “plaque simulator.” Each arch was brushed twice with each of the four toothbrushes, one minute by the same operator, blinded to the study. The plaque index (PI) was recorded at the end of each brushing session. GLM for repeated measures analysed the data. Results. On all the casts, the manual prototype and the electric prototype, removed 11% and 14% more “plaque simulator” compared to the standard toothbrush. In presence of dental anomalies, the prototypes removed 13% and 16% more plaque, respectively, compared to standard toothbrushes (P = 0.04). In both situations, the 95% confidence intervals of PI did not include −10% (the minimal margin of clinical relevance). Conclusions. The prototype is more effective in removing plaque from the casts with anomalies. The noninferiority of the prototype with respect to the standard toothbrushes was demonstrated. Hindawi Publishing Corporation 2014 2014-11-18 /pmc/articles/PMC4251081/ /pubmed/25485301 http://dx.doi.org/10.1155/2014/763968 Text en Copyright © 2014 Lorenzo Mazza et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Mazza, Lorenzo
Gatto, Maria Rosaria
Monaco, Giuseppe
Pelliccioni, Gian Andrea
A Laboratory Based Investigation of a New Elastic Toothbrush Head
title A Laboratory Based Investigation of a New Elastic Toothbrush Head
title_full A Laboratory Based Investigation of a New Elastic Toothbrush Head
title_fullStr A Laboratory Based Investigation of a New Elastic Toothbrush Head
title_full_unstemmed A Laboratory Based Investigation of a New Elastic Toothbrush Head
title_short A Laboratory Based Investigation of a New Elastic Toothbrush Head
title_sort laboratory based investigation of a new elastic toothbrush head
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4251081/
https://www.ncbi.nlm.nih.gov/pubmed/25485301
http://dx.doi.org/10.1155/2014/763968
work_keys_str_mv AT mazzalorenzo alaboratorybasedinvestigationofanewelastictoothbrushhead
AT gattomariarosaria alaboratorybasedinvestigationofanewelastictoothbrushhead
AT monacogiuseppe alaboratorybasedinvestigationofanewelastictoothbrushhead
AT pelliccionigianandrea alaboratorybasedinvestigationofanewelastictoothbrushhead
AT mazzalorenzo laboratorybasedinvestigationofanewelastictoothbrushhead
AT gattomariarosaria laboratorybasedinvestigationofanewelastictoothbrushhead
AT monacogiuseppe laboratorybasedinvestigationofanewelastictoothbrushhead
AT pelliccionigianandrea laboratorybasedinvestigationofanewelastictoothbrushhead