Ultrasound-Guided Small Vessel Cannulation: Long-Axis Approach Is Equivalent to Short-Axis in Novice Sonographers Experienced with Landmark-Based Cannulation
INTRODUCTION: Our primary objective was to describe the time to vessel penetration and difficulty of long-axis and short-axis approaches for ultrasound-guided small vessel penetration in novice sonographers experienced with landmark-based small vessel penetration. METHODS: This was a prospective, ob...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Department of Emergency Medicine, University of California, Irvine School of Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4251227/ https://www.ncbi.nlm.nih.gov/pubmed/25493126 http://dx.doi.org/10.5811/westjem.2014.9.22404 |
Sumario: | INTRODUCTION: Our primary objective was to describe the time to vessel penetration and difficulty of long-axis and short-axis approaches for ultrasound-guided small vessel penetration in novice sonographers experienced with landmark-based small vessel penetration. METHODS: This was a prospective, observational study of experienced certified emergency nurses attempting ultrasound-guided small vessel cannulation on a vascular access phantom. We conducted a standardized training, practice, and experiment session for each participant. Five long-axis and five short-axis approaches were attempted in alternating sequence. The primary outcome was time to vessel penetration. Secondary outcomes were number of skin penetrations and number of catheter redirections. We compared long-axis and short-axis approaches using multivariable regression adjusting for repeated measures, vessel depth, and vessel caliber. RESULTS: Each of 10 novice sonographers made 10 attempts for a total of 100 attempts. Median time to vessel penetration in the long-axis and short-axis was 11 (95% confidence interval [CI] 7–12) and 10 (95% CI 6–13) seconds, respectively. Skin penetrations and catheter redirections were equivalent and near optimal between approaches. The median caliber of cannulated vessels in the long-axis and short-axis was 4.6 (95% CI 4.1–5.5) and 5.6 (95% CI 5.1–6.2) millimeters, respectively. Both axes had equal success rates of 100% for all 50 attempts. In multivariable regression analysis, long-axis attempts were 32% (95% CI 11%–48%; p=0.009) faster than short-axis attempts. CONCLUSION: Novice sonographers, highly proficient with peripheral IV cannulation, can perform after instruction ultrasound-guided small vessel penetration successfully with similar time to vessel penetration in either the long-axis or short-axis approach on phantom models. |
---|