Cargando…
Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report
Pulmonary artery (PA) rupture caused by a PA Swan-Ganz catheter is a rare complication but remains fatal in almost 50% of cases. False aneurysm of the PA is a rare presentation of PA rupture and should be considered as a possible diagnosis in a patient with a new lung mass after PA catheterization....
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Anesthesiologists
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4252348/ https://www.ncbi.nlm.nih.gov/pubmed/25473465 http://dx.doi.org/10.4097/kjae.2014.67.5.346 |
_version_ | 1782347178758373376 |
---|---|
author | Sugiyama, Daisuke Ikeno, Shigeo Tsuchihashi, Tetsuya Yokota, Shigeru Ina, Hiroaki Kono, Tetsuya Yamashita, Kunihiko Kawamata, Mikito |
author_facet | Sugiyama, Daisuke Ikeno, Shigeo Tsuchihashi, Tetsuya Yokota, Shigeru Ina, Hiroaki Kono, Tetsuya Yamashita, Kunihiko Kawamata, Mikito |
author_sort | Sugiyama, Daisuke |
collection | PubMed |
description | Pulmonary artery (PA) rupture caused by a PA Swan-Ganz catheter is a rare complication but remains fatal in almost 50% of cases. False aneurysm of the PA is a rare presentation of PA rupture and should be considered as a possible diagnosis in a patient with a new lung mass after PA catheterization. We present a case of sudden-onset pulmonary alveolar hemorrhage during cardiovascular surgery due to a traumatic PA false aneurysm. The Swan-Ganz catheter might have been displaced by the thoracic aortic aneurysm with displacement of the catheter causing the false aneurysm and bleeding. |
format | Online Article Text |
id | pubmed-4252348 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Society of Anesthesiologists |
record_format | MEDLINE/PubMed |
spelling | pubmed-42523482014-12-03 Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report Sugiyama, Daisuke Ikeno, Shigeo Tsuchihashi, Tetsuya Yokota, Shigeru Ina, Hiroaki Kono, Tetsuya Yamashita, Kunihiko Kawamata, Mikito Korean J Anesthesiol Case Report Pulmonary artery (PA) rupture caused by a PA Swan-Ganz catheter is a rare complication but remains fatal in almost 50% of cases. False aneurysm of the PA is a rare presentation of PA rupture and should be considered as a possible diagnosis in a patient with a new lung mass after PA catheterization. We present a case of sudden-onset pulmonary alveolar hemorrhage during cardiovascular surgery due to a traumatic PA false aneurysm. The Swan-Ganz catheter might have been displaced by the thoracic aortic aneurysm with displacement of the catheter causing the false aneurysm and bleeding. The Korean Society of Anesthesiologists 2014-11 2014-11-26 /pmc/articles/PMC4252348/ /pubmed/25473465 http://dx.doi.org/10.4097/kjae.2014.67.5.346 Text en Copyright © the Korean Society of Anesthesiologists, 2014 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Sugiyama, Daisuke Ikeno, Shigeo Tsuchihashi, Tetsuya Yokota, Shigeru Ina, Hiroaki Kono, Tetsuya Yamashita, Kunihiko Kawamata, Mikito Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report |
title | Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report |
title_full | Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report |
title_fullStr | Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report |
title_full_unstemmed | Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report |
title_short | Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report |
title_sort | pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after swan-ganz catheterization in a thoracic aortic aneurysm patient: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4252348/ https://www.ncbi.nlm.nih.gov/pubmed/25473465 http://dx.doi.org/10.4097/kjae.2014.67.5.346 |
work_keys_str_mv | AT sugiyamadaisuke pulmonaryalveolarhemorrhagefromapulmonaryarteryfalseaneurysmafterswanganzcatheterizationinathoracicaorticaneurysmpatientacasereport AT ikenoshigeo pulmonaryalveolarhemorrhagefromapulmonaryarteryfalseaneurysmafterswanganzcatheterizationinathoracicaorticaneurysmpatientacasereport AT tsuchihashitetsuya pulmonaryalveolarhemorrhagefromapulmonaryarteryfalseaneurysmafterswanganzcatheterizationinathoracicaorticaneurysmpatientacasereport AT yokotashigeru pulmonaryalveolarhemorrhagefromapulmonaryarteryfalseaneurysmafterswanganzcatheterizationinathoracicaorticaneurysmpatientacasereport AT inahiroaki pulmonaryalveolarhemorrhagefromapulmonaryarteryfalseaneurysmafterswanganzcatheterizationinathoracicaorticaneurysmpatientacasereport AT konotetsuya pulmonaryalveolarhemorrhagefromapulmonaryarteryfalseaneurysmafterswanganzcatheterizationinathoracicaorticaneurysmpatientacasereport AT yamashitakunihiko pulmonaryalveolarhemorrhagefromapulmonaryarteryfalseaneurysmafterswanganzcatheterizationinathoracicaorticaneurysmpatientacasereport AT kawamatamikito pulmonaryalveolarhemorrhagefromapulmonaryarteryfalseaneurysmafterswanganzcatheterizationinathoracicaorticaneurysmpatientacasereport |