Cargando…

Shear bond strength of novel calcium aluminate-based cement (EndoBinder) to root dentine

OBJECTIVE: To evaluate the shear bond strength of a novel calcium aluminate-based cement, EndoBinder (EB), to dentine in comparison with Grey and White Mineral Trioxide Aggregate (MTA). MATERIALS AND METHODS: Root canal hemi-sections obtained from 30 extracted molar teeth were embedded in self-polym...

Descripción completa

Detalles Bibliográficos
Autores principales: Garcia, Lucas da Fonseca Roberti, Rossetto, Hebert Luis, Pires-de-Souza, Fernanda de Carvalho Panzeri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4253106/
https://www.ncbi.nlm.nih.gov/pubmed/25512731
http://dx.doi.org/10.4103/1305-7456.143632
_version_ 1782347226750648320
author Garcia, Lucas da Fonseca Roberti
Rossetto, Hebert Luis
Pires-de-Souza, Fernanda de Carvalho Panzeri
author_facet Garcia, Lucas da Fonseca Roberti
Rossetto, Hebert Luis
Pires-de-Souza, Fernanda de Carvalho Panzeri
author_sort Garcia, Lucas da Fonseca Roberti
collection PubMed
description OBJECTIVE: To evaluate the shear bond strength of a novel calcium aluminate-based cement, EndoBinder (EB), to dentine in comparison with Grey and White Mineral Trioxide Aggregate (MTA). MATERIALS AND METHODS: Root canal hemi-sections obtained from 30 extracted molar teeth were embedded in self-polymerized acrylic resin and were grounded wet in order to obtain a flat dentine surface. Next, the roots were randomly assigned into three groups (n = 10), according to the cement used, as follows: EB: EndoBinder; WMTA: White MTA and GMTA: Grey MTA. The shear bond strength test was performed using a Universal Testing Machine (0.5 mm/min) and the data were submitted to statistical analysis (1-way ANOVA and Tukey tests, P < 0.05). RESULTS: EB presented the highest shear bond strength values; however, there was no statistically significant difference in comparison with GMTA (P > 0.05). WMTA presented the lowest mean values, which were significant in comparison with EB (P < 0.05). CONCLUSIONS: The novel calcium aluminate-based cement presented higher shear bond strength than WMTA, and should be considered as a promising alternative in endodontic therapy.
format Online
Article
Text
id pubmed-4253106
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-42531062014-12-15 Shear bond strength of novel calcium aluminate-based cement (EndoBinder) to root dentine Garcia, Lucas da Fonseca Roberti Rossetto, Hebert Luis Pires-de-Souza, Fernanda de Carvalho Panzeri Eur J Dent Original Article OBJECTIVE: To evaluate the shear bond strength of a novel calcium aluminate-based cement, EndoBinder (EB), to dentine in comparison with Grey and White Mineral Trioxide Aggregate (MTA). MATERIALS AND METHODS: Root canal hemi-sections obtained from 30 extracted molar teeth were embedded in self-polymerized acrylic resin and were grounded wet in order to obtain a flat dentine surface. Next, the roots were randomly assigned into three groups (n = 10), according to the cement used, as follows: EB: EndoBinder; WMTA: White MTA and GMTA: Grey MTA. The shear bond strength test was performed using a Universal Testing Machine (0.5 mm/min) and the data were submitted to statistical analysis (1-way ANOVA and Tukey tests, P < 0.05). RESULTS: EB presented the highest shear bond strength values; however, there was no statistically significant difference in comparison with GMTA (P > 0.05). WMTA presented the lowest mean values, which were significant in comparison with EB (P < 0.05). CONCLUSIONS: The novel calcium aluminate-based cement presented higher shear bond strength than WMTA, and should be considered as a promising alternative in endodontic therapy. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4253106/ /pubmed/25512731 http://dx.doi.org/10.4103/1305-7456.143632 Text en Copyright: © European Journal of Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Garcia, Lucas da Fonseca Roberti
Rossetto, Hebert Luis
Pires-de-Souza, Fernanda de Carvalho Panzeri
Shear bond strength of novel calcium aluminate-based cement (EndoBinder) to root dentine
title Shear bond strength of novel calcium aluminate-based cement (EndoBinder) to root dentine
title_full Shear bond strength of novel calcium aluminate-based cement (EndoBinder) to root dentine
title_fullStr Shear bond strength of novel calcium aluminate-based cement (EndoBinder) to root dentine
title_full_unstemmed Shear bond strength of novel calcium aluminate-based cement (EndoBinder) to root dentine
title_short Shear bond strength of novel calcium aluminate-based cement (EndoBinder) to root dentine
title_sort shear bond strength of novel calcium aluminate-based cement (endobinder) to root dentine
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4253106/
https://www.ncbi.nlm.nih.gov/pubmed/25512731
http://dx.doi.org/10.4103/1305-7456.143632
work_keys_str_mv AT garcialucasdafonsecaroberti shearbondstrengthofnovelcalciumaluminatebasedcementendobindertorootdentine
AT rossettohebertluis shearbondstrengthofnovelcalciumaluminatebasedcementendobindertorootdentine
AT piresdesouzafernandadecarvalhopanzeri shearbondstrengthofnovelcalciumaluminatebasedcementendobindertorootdentine