Cargando…

Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles

BACKGROUND: Whole blood expression profiling is frequently performed using PAXgene (Qiagen) or Tempus (Life Technologies) tubes. Here, we compare 6 novel generation RNA isolation protocols with respect to RNA quantity, quality and recovery of mRNA and miRNA. METHODS: 3 PAXgene and 3 Tempus Tubes wer...

Descripción completa

Detalles Bibliográficos
Autores principales: Häntzsch, Madlen, Tolios, Alexander, Beutner, Frank, Nagel, Dorothea, Thiery, Joachim, Teupser, Daniel, Holdt, Lesca M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4254602/
https://www.ncbi.nlm.nih.gov/pubmed/25469788
http://dx.doi.org/10.1371/journal.pone.0113298
_version_ 1782347349391048704
author Häntzsch, Madlen
Tolios, Alexander
Beutner, Frank
Nagel, Dorothea
Thiery, Joachim
Teupser, Daniel
Holdt, Lesca M.
author_facet Häntzsch, Madlen
Tolios, Alexander
Beutner, Frank
Nagel, Dorothea
Thiery, Joachim
Teupser, Daniel
Holdt, Lesca M.
author_sort Häntzsch, Madlen
collection PubMed
description BACKGROUND: Whole blood expression profiling is frequently performed using PAXgene (Qiagen) or Tempus (Life Technologies) tubes. Here, we compare 6 novel generation RNA isolation protocols with respect to RNA quantity, quality and recovery of mRNA and miRNA. METHODS: 3 PAXgene and 3 Tempus Tubes were collected from participants of the LIFE study with (n = 12) and without (n = 35) acute myocardial infarction (AMI). RNA was extracted with 4 manual protocols from Qiagen (PAXgene Blood miRNA Kit), Life Technologies (MagMAX for Stabilized Blood Tubes RNA Isolation Kit), and Norgen Biotek (Norgen Preserved Blood RNA Purification Kit I and Kit II), and 2 (semi-)automated protocols on the QIAsymphony (Qiagen) and MagMAX Express-96 Magnetic Particle Processor (Life Technologies). RNA quantity and quality was determined. For biological validation, RNA from 12 representative probands, extracted with all 6 kits (n = 72), was reverse transcribed and mRNAs (matrix metalloproteinase 9, arginase 1) and miRNAs (miR133a, miR1), shown to be altered by AMI, were analyzed. RESULTS: RNA yields were highest using the Norgen Kit I with Tempus Tubes and lowest using the Norgen Kit II with PAXgene. The disease status was the second major determinant of RNA yields (LIFE-AMI 11.2 vs. LIFE 6.7 µg, p<0.001) followed by the choice of blood collection tube. (Semi-)automation reduced overall RNA extraction time but did not generally reduce hands-on-time. RNA yields and quality were comparable between manual and automated extraction protocols. mRNA expression was not affected by collection tubes and RNA extraction kits but by RT/qPCR reagents with exception of the Norgen Kit II, which led to mRNA depletion. For miRNAs, expression differences related to collection tubes (miR30b), RNA isolation (Norgen Kit II), and RT/qRT reagents (miR133a) were observed. CONCLUSION: We demonstrate that novel generation RNA isolation kits significantly differed with respect to RNA recovery and affected miRNA but not mRNA expression profiles.
format Online
Article
Text
id pubmed-4254602
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-42546022014-12-11 Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles Häntzsch, Madlen Tolios, Alexander Beutner, Frank Nagel, Dorothea Thiery, Joachim Teupser, Daniel Holdt, Lesca M. PLoS One Research Article BACKGROUND: Whole blood expression profiling is frequently performed using PAXgene (Qiagen) or Tempus (Life Technologies) tubes. Here, we compare 6 novel generation RNA isolation protocols with respect to RNA quantity, quality and recovery of mRNA and miRNA. METHODS: 3 PAXgene and 3 Tempus Tubes were collected from participants of the LIFE study with (n = 12) and without (n = 35) acute myocardial infarction (AMI). RNA was extracted with 4 manual protocols from Qiagen (PAXgene Blood miRNA Kit), Life Technologies (MagMAX for Stabilized Blood Tubes RNA Isolation Kit), and Norgen Biotek (Norgen Preserved Blood RNA Purification Kit I and Kit II), and 2 (semi-)automated protocols on the QIAsymphony (Qiagen) and MagMAX Express-96 Magnetic Particle Processor (Life Technologies). RNA quantity and quality was determined. For biological validation, RNA from 12 representative probands, extracted with all 6 kits (n = 72), was reverse transcribed and mRNAs (matrix metalloproteinase 9, arginase 1) and miRNAs (miR133a, miR1), shown to be altered by AMI, were analyzed. RESULTS: RNA yields were highest using the Norgen Kit I with Tempus Tubes and lowest using the Norgen Kit II with PAXgene. The disease status was the second major determinant of RNA yields (LIFE-AMI 11.2 vs. LIFE 6.7 µg, p<0.001) followed by the choice of blood collection tube. (Semi-)automation reduced overall RNA extraction time but did not generally reduce hands-on-time. RNA yields and quality were comparable between manual and automated extraction protocols. mRNA expression was not affected by collection tubes and RNA extraction kits but by RT/qPCR reagents with exception of the Norgen Kit II, which led to mRNA depletion. For miRNAs, expression differences related to collection tubes (miR30b), RNA isolation (Norgen Kit II), and RT/qRT reagents (miR133a) were observed. CONCLUSION: We demonstrate that novel generation RNA isolation kits significantly differed with respect to RNA recovery and affected miRNA but not mRNA expression profiles. Public Library of Science 2014-12-03 /pmc/articles/PMC4254602/ /pubmed/25469788 http://dx.doi.org/10.1371/journal.pone.0113298 Text en © 2014 Häntzsch et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Häntzsch, Madlen
Tolios, Alexander
Beutner, Frank
Nagel, Dorothea
Thiery, Joachim
Teupser, Daniel
Holdt, Lesca M.
Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles
title Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles
title_full Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles
title_fullStr Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles
title_full_unstemmed Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles
title_short Comparison of Whole Blood RNA Preservation Tubes and Novel Generation RNA Extraction Kits for Analysis of mRNA and MiRNA Profiles
title_sort comparison of whole blood rna preservation tubes and novel generation rna extraction kits for analysis of mrna and mirna profiles
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4254602/
https://www.ncbi.nlm.nih.gov/pubmed/25469788
http://dx.doi.org/10.1371/journal.pone.0113298
work_keys_str_mv AT hantzschmadlen comparisonofwholebloodrnapreservationtubesandnovelgenerationrnaextractionkitsforanalysisofmrnaandmirnaprofiles
AT toliosalexander comparisonofwholebloodrnapreservationtubesandnovelgenerationrnaextractionkitsforanalysisofmrnaandmirnaprofiles
AT beutnerfrank comparisonofwholebloodrnapreservationtubesandnovelgenerationrnaextractionkitsforanalysisofmrnaandmirnaprofiles
AT nageldorothea comparisonofwholebloodrnapreservationtubesandnovelgenerationrnaextractionkitsforanalysisofmrnaandmirnaprofiles
AT thieryjoachim comparisonofwholebloodrnapreservationtubesandnovelgenerationrnaextractionkitsforanalysisofmrnaandmirnaprofiles
AT teupserdaniel comparisonofwholebloodrnapreservationtubesandnovelgenerationrnaextractionkitsforanalysisofmrnaandmirnaprofiles
AT holdtlescam comparisonofwholebloodrnapreservationtubesandnovelgenerationrnaextractionkitsforanalysisofmrnaandmirnaprofiles