Cargando…
The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
OBJECTIVES: The transoral atlantoaxial reduction plate system treats irreducible atlantoaxial dislocation from transoral atlantoaxial reduction plate-I to transoral atlantoaxial reduction plate-III. However, this system has demonstrated problems associated with screw loosening, atlantoaxial fixation...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4255074/ https://www.ncbi.nlm.nih.gov/pubmed/25518033 http://dx.doi.org/10.6061/clinics/2014(11)08 |
_version_ | 1782347389089087488 |
---|---|
author | Li, Xue-Shi Wu, Zeng-Hui Xia, Hong Ma, Xiang-Yang Ai, Fu-Zhi Zhang, Kai Wang, Jian-Hua Mai, Xiao-Hong Yin, Qing-Shui |
author_facet | Li, Xue-Shi Wu, Zeng-Hui Xia, Hong Ma, Xiang-Yang Ai, Fu-Zhi Zhang, Kai Wang, Jian-Hua Mai, Xiao-Hong Yin, Qing-Shui |
author_sort | Li, Xue-Shi |
collection | PubMed |
description | OBJECTIVES: The transoral atlantoaxial reduction plate system treats irreducible atlantoaxial dislocation from transoral atlantoaxial reduction plate-I to transoral atlantoaxial reduction plate-III. However, this system has demonstrated problems associated with screw loosening, atlantoaxial fixation and concealed or manifest neurovascular injuries. This study sought to design a set of individualized templates to improve the accuracy of anterior C2 screw placement in the transoral atlantoaxial reduction plate-IV procedure. METHODS: A set of individualized templates was designed according to thin-slice computed tomography data obtained from 10 human cadavers. The templates contained cubic modules and drill guides to facilitate transoral atlantoaxial reduction plate positioning and anterior C2 screw placement. We performed 2 stages of cadaveric experiments with 2 cadavers in stage one and 8 in stage two. Finally, guided C2 screw placement was evaluated by reading postoperative computed tomography images and comparing the planned and inserted screw trajectories. RESULTS: There were two cortical breaching screws in stage one and three in stage two, but only the cortical breaching screws in stage one were ranked critical. In stage two, the planned entry points and the transverse angles of the anterior C2 screws could be simulated, whereas the declination angles could not be simulated due to intraoperative blockage of the drill bit and screwdriver by the upper teeth. CONCLUSIONS: It was feasible to use individualized templates to guide transoral C2 screw placement. Thus, these drill templates combined with transoral atlantoaxial reduction plate-IV, may improve the accuracy of transoral C2 screw placement and reduce related neurovascular complications. |
format | Online Article Text |
id | pubmed-4255074 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-42550742014-12-05 The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study Li, Xue-Shi Wu, Zeng-Hui Xia, Hong Ma, Xiang-Yang Ai, Fu-Zhi Zhang, Kai Wang, Jian-Hua Mai, Xiao-Hong Yin, Qing-Shui Clinics (Sao Paulo) Clinical Science OBJECTIVES: The transoral atlantoaxial reduction plate system treats irreducible atlantoaxial dislocation from transoral atlantoaxial reduction plate-I to transoral atlantoaxial reduction plate-III. However, this system has demonstrated problems associated with screw loosening, atlantoaxial fixation and concealed or manifest neurovascular injuries. This study sought to design a set of individualized templates to improve the accuracy of anterior C2 screw placement in the transoral atlantoaxial reduction plate-IV procedure. METHODS: A set of individualized templates was designed according to thin-slice computed tomography data obtained from 10 human cadavers. The templates contained cubic modules and drill guides to facilitate transoral atlantoaxial reduction plate positioning and anterior C2 screw placement. We performed 2 stages of cadaveric experiments with 2 cadavers in stage one and 8 in stage two. Finally, guided C2 screw placement was evaluated by reading postoperative computed tomography images and comparing the planned and inserted screw trajectories. RESULTS: There were two cortical breaching screws in stage one and three in stage two, but only the cortical breaching screws in stage one were ranked critical. In stage two, the planned entry points and the transverse angles of the anterior C2 screws could be simulated, whereas the declination angles could not be simulated due to intraoperative blockage of the drill bit and screwdriver by the upper teeth. CONCLUSIONS: It was feasible to use individualized templates to guide transoral C2 screw placement. Thus, these drill templates combined with transoral atlantoaxial reduction plate-IV, may improve the accuracy of transoral C2 screw placement and reduce related neurovascular complications. Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2014-11 /pmc/articles/PMC4255074/ /pubmed/25518033 http://dx.doi.org/10.6061/clinics/2014(11)08 Text en Copyright © 2014 Hospital das Clínicas da FMUSP http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Science Li, Xue-Shi Wu, Zeng-Hui Xia, Hong Ma, Xiang-Yang Ai, Fu-Zhi Zhang, Kai Wang, Jian-Hua Mai, Xiao-Hong Yin, Qing-Shui The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study |
title | The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study |
title_full | The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study |
title_fullStr | The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study |
title_full_unstemmed | The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study |
title_short | The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study |
title_sort | development and evaluation of individualized templates to assist transoral c2 articular mass or transpedicular screw placement in tarp-iv procedures: adult cadaver specimen study |
topic | Clinical Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4255074/ https://www.ncbi.nlm.nih.gov/pubmed/25518033 http://dx.doi.org/10.6061/clinics/2014(11)08 |
work_keys_str_mv | AT lixueshi thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT wuzenghui thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT xiahong thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT maxiangyang thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT aifuzhi thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT zhangkai thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT wangjianhua thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT maixiaohong thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT yinqingshui thedevelopmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT lixueshi developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT wuzenghui developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT xiahong developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT maxiangyang developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT aifuzhi developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT zhangkai developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT wangjianhua developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT maixiaohong developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy AT yinqingshui developmentandevaluationofindividualizedtemplatestoassisttransoralc2articularmassortranspedicularscrewplacementintarpivproceduresadultcadaverspecimenstudy |