Cargando…

Performance evaluation of laboratory professionals on malaria microscopy in Hawassa Town, Southern Ethiopia

BACKGROUND: Microscopic diagnosis of Giemsa stained thick and thin blood films by skilled microscopists has remained the standard laboratory method for the diagnosis of malaria. However, detection and identification of malaria parasites require well trained laboratory personnel. The objective of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Ayalew, Freshwork, Tilahun, Birkneh, Taye, Bineyam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4255633/
https://www.ncbi.nlm.nih.gov/pubmed/25422030
http://dx.doi.org/10.1186/1756-0500-7-839
_version_ 1782347460754014208
author Ayalew, Freshwork
Tilahun, Birkneh
Taye, Bineyam
author_facet Ayalew, Freshwork
Tilahun, Birkneh
Taye, Bineyam
author_sort Ayalew, Freshwork
collection PubMed
description BACKGROUND: Microscopic diagnosis of Giemsa stained thick and thin blood films by skilled microscopists has remained the standard laboratory method for the diagnosis of malaria. However, detection and identification of malaria parasites require well trained laboratory personnel. The objective of the study was to evaluate the performance of laboratory technologists and technicians in detecting and identifying malaria parasites in Hawassa town, Southern Ethiopia. METHODS: A cross-sectional study design was employed among a total of 80 laboratory professionals working in public and private health facilities. A standardized pre-validated slide panel and questionnaires were distributed to laboratory professionals working at eleven health facilities in Hawassa town, Southern Ethiopia. The panels included ten slides for diagnosis, [slide1:P.falciparum, 104/μl; slide 2:P.falciparum, 53404/μl; slide 3 and 4: mixed infection (both P. falciparum and P. vivax); slide 5:P.vivax, 23503/μl; slide 6:P.vivax, 400/μl; and slides 7, 8, 9 and 10: negative slides]. Participants were asked to return the responses which were compared with expert microscopist. Agreement in detecting and identifying malaria parasites between participants and expert microscopists was estimated using the Kappa score. RESULTS: The mean age of the participants was 27 (SD = 4.1) years. More than half of the participants (56.9%) were female. Fourteen (19.4%) of the participants correctly reported all the ten distributed slides, whereas 58(80.6%) missed at least one slide. Overall, the sensitivity and specificity of participants in detection of malaria parasites were 82% and 96.5% respectively. The overall agreement between participants and reference readers on detection of malaria parasite was 88% (Kappa = 0.76) while on identification of malaria species was 74.3% (kappa = 0.63). Lower agreement on detection and identification of slides with low parasitic density and mixed infection were observed. Agreement was relatively lower for government health centers (69%; kappa = 0.56). None of the participants reported parasitic load per micro liter method. CONCLUSION: Agreement of the participants with expert microscopist in the detection of malaria parasites was better than agreement in the identification of different species of malaria. Poor agreement was reported in detection of parasites at a low density and mixed infections.
format Online
Article
Text
id pubmed-4255633
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42556332014-12-05 Performance evaluation of laboratory professionals on malaria microscopy in Hawassa Town, Southern Ethiopia Ayalew, Freshwork Tilahun, Birkneh Taye, Bineyam BMC Res Notes Research Article BACKGROUND: Microscopic diagnosis of Giemsa stained thick and thin blood films by skilled microscopists has remained the standard laboratory method for the diagnosis of malaria. However, detection and identification of malaria parasites require well trained laboratory personnel. The objective of the study was to evaluate the performance of laboratory technologists and technicians in detecting and identifying malaria parasites in Hawassa town, Southern Ethiopia. METHODS: A cross-sectional study design was employed among a total of 80 laboratory professionals working in public and private health facilities. A standardized pre-validated slide panel and questionnaires were distributed to laboratory professionals working at eleven health facilities in Hawassa town, Southern Ethiopia. The panels included ten slides for diagnosis, [slide1:P.falciparum, 104/μl; slide 2:P.falciparum, 53404/μl; slide 3 and 4: mixed infection (both P. falciparum and P. vivax); slide 5:P.vivax, 23503/μl; slide 6:P.vivax, 400/μl; and slides 7, 8, 9 and 10: negative slides]. Participants were asked to return the responses which were compared with expert microscopist. Agreement in detecting and identifying malaria parasites between participants and expert microscopists was estimated using the Kappa score. RESULTS: The mean age of the participants was 27 (SD = 4.1) years. More than half of the participants (56.9%) were female. Fourteen (19.4%) of the participants correctly reported all the ten distributed slides, whereas 58(80.6%) missed at least one slide. Overall, the sensitivity and specificity of participants in detection of malaria parasites were 82% and 96.5% respectively. The overall agreement between participants and reference readers on detection of malaria parasite was 88% (Kappa = 0.76) while on identification of malaria species was 74.3% (kappa = 0.63). Lower agreement on detection and identification of slides with low parasitic density and mixed infection were observed. Agreement was relatively lower for government health centers (69%; kappa = 0.56). None of the participants reported parasitic load per micro liter method. CONCLUSION: Agreement of the participants with expert microscopist in the detection of malaria parasites was better than agreement in the identification of different species of malaria. Poor agreement was reported in detection of parasites at a low density and mixed infections. BioMed Central 2014-11-25 /pmc/articles/PMC4255633/ /pubmed/25422030 http://dx.doi.org/10.1186/1756-0500-7-839 Text en © Ayalew et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Ayalew, Freshwork
Tilahun, Birkneh
Taye, Bineyam
Performance evaluation of laboratory professionals on malaria microscopy in Hawassa Town, Southern Ethiopia
title Performance evaluation of laboratory professionals on malaria microscopy in Hawassa Town, Southern Ethiopia
title_full Performance evaluation of laboratory professionals on malaria microscopy in Hawassa Town, Southern Ethiopia
title_fullStr Performance evaluation of laboratory professionals on malaria microscopy in Hawassa Town, Southern Ethiopia
title_full_unstemmed Performance evaluation of laboratory professionals on malaria microscopy in Hawassa Town, Southern Ethiopia
title_short Performance evaluation of laboratory professionals on malaria microscopy in Hawassa Town, Southern Ethiopia
title_sort performance evaluation of laboratory professionals on malaria microscopy in hawassa town, southern ethiopia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4255633/
https://www.ncbi.nlm.nih.gov/pubmed/25422030
http://dx.doi.org/10.1186/1756-0500-7-839
work_keys_str_mv AT ayalewfreshwork performanceevaluationoflaboratoryprofessionalsonmalariamicroscopyinhawassatownsouthernethiopia
AT tilahunbirkneh performanceevaluationoflaboratoryprofessionalsonmalariamicroscopyinhawassatownsouthernethiopia
AT tayebineyam performanceevaluationoflaboratoryprofessionalsonmalariamicroscopyinhawassatownsouthernethiopia