Cargando…
Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index
INTRODUCTION: The critically-ill undergoing inter-hospital transfers commonly receive sedatives in continuation of their therapeutic regime or to facilitate a safe transfer shielded from external stressors. While sedation assessment is well established in critical care in general, there is only litt...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4256754/ https://www.ncbi.nlm.nih.gov/pubmed/25418521 http://dx.doi.org/10.1186/s13054-014-0615-9 |
_version_ | 1782347629868351488 |
---|---|
author | Prottengeier, Johannes Moritz, Andreas Heinrich, Sebastian Gall, Christine Schmidt, Joachim |
author_facet | Prottengeier, Johannes Moritz, Andreas Heinrich, Sebastian Gall, Christine Schmidt, Joachim |
author_sort | Prottengeier, Johannes |
collection | PubMed |
description | INTRODUCTION: The critically-ill undergoing inter-hospital transfers commonly receive sedatives in continuation of their therapeutic regime or to facilitate a safe transfer shielded from external stressors. While sedation assessment is well established in critical care in general, there is only little data available relating to the special conditions during patient transport and their effect on patient sedation levels. The aim of this prospective study was to investigate the feasibility and relationship of clinical sedation assessment (Richmond Agitation-Sedation Scale (RASS)) and objective physiological monitoring (bispectral index (BIS)) during patient transfers in our Mobile-ICU. METHODS: The levels of sedation of 30 pharmacologically sedated patients were evaluated at 12 to 17 distinct measurement points spread strategically over the course of a transfer by use of the RASS and BIS. To investigate the relation between the RASS and the BIS, Spearman’s squared rank correlation coefficient (ρ(2)) and the Kendall’s rank correlation coefficient (τ) were calculated. The diagnostic value of the BIS with respect to the RASS was investigated by its sensitivity and positive predictive value for possible patient awakening. Therefore, measurements were dichotomized considering a clinically sensible threshold of 80 for BIS-values and classifying RASS values being nonnegative. RESULTS: Spearman’s rank correlation resulted to ρ(2) = 0.431 (confidence interval (CI) = 0.341 to 0.513). The Kendall’s correlation coefficient was calculated as τ = 0.522 (CI = 0.459 to 0.576). Awakening of patients (RASS ≥0) was detected by a BIS value of 80 and above with a sensitivity of 0.97 (CI = 0.89 to 1.00) and a positive predictive value of 0.59 (CI = 0.45 to 0.71). CONCLUSIONS: Our study demonstrates that the BIS-Monitor can be used for the assessment of sedation levels in the intricate environment of a Mobile-ICU, especially when well-established clinical scores as the RASS are impracticable. The use of BIS is highly sensitive in the detection of unwanted awakening of patients during transfers. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13054-014-0615-9) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4256754 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42567542014-12-05 Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index Prottengeier, Johannes Moritz, Andreas Heinrich, Sebastian Gall, Christine Schmidt, Joachim Crit Care Research INTRODUCTION: The critically-ill undergoing inter-hospital transfers commonly receive sedatives in continuation of their therapeutic regime or to facilitate a safe transfer shielded from external stressors. While sedation assessment is well established in critical care in general, there is only little data available relating to the special conditions during patient transport and their effect on patient sedation levels. The aim of this prospective study was to investigate the feasibility and relationship of clinical sedation assessment (Richmond Agitation-Sedation Scale (RASS)) and objective physiological monitoring (bispectral index (BIS)) during patient transfers in our Mobile-ICU. METHODS: The levels of sedation of 30 pharmacologically sedated patients were evaluated at 12 to 17 distinct measurement points spread strategically over the course of a transfer by use of the RASS and BIS. To investigate the relation between the RASS and the BIS, Spearman’s squared rank correlation coefficient (ρ(2)) and the Kendall’s rank correlation coefficient (τ) were calculated. The diagnostic value of the BIS with respect to the RASS was investigated by its sensitivity and positive predictive value for possible patient awakening. Therefore, measurements were dichotomized considering a clinically sensible threshold of 80 for BIS-values and classifying RASS values being nonnegative. RESULTS: Spearman’s rank correlation resulted to ρ(2) = 0.431 (confidence interval (CI) = 0.341 to 0.513). The Kendall’s correlation coefficient was calculated as τ = 0.522 (CI = 0.459 to 0.576). Awakening of patients (RASS ≥0) was detected by a BIS value of 80 and above with a sensitivity of 0.97 (CI = 0.89 to 1.00) and a positive predictive value of 0.59 (CI = 0.45 to 0.71). CONCLUSIONS: Our study demonstrates that the BIS-Monitor can be used for the assessment of sedation levels in the intricate environment of a Mobile-ICU, especially when well-established clinical scores as the RASS are impracticable. The use of BIS is highly sensitive in the detection of unwanted awakening of patients during transfers. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13054-014-0615-9) contains supplementary material, which is available to authorized users. BioMed Central 2014-11-24 2014 /pmc/articles/PMC4256754/ /pubmed/25418521 http://dx.doi.org/10.1186/s13054-014-0615-9 Text en © Prottengeier et al.; licensee BioMed Central Ltd. 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Prottengeier, Johannes Moritz, Andreas Heinrich, Sebastian Gall, Christine Schmidt, Joachim Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index |
title | Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index |
title_full | Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index |
title_fullStr | Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index |
title_full_unstemmed | Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index |
title_short | Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index |
title_sort | sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4256754/ https://www.ncbi.nlm.nih.gov/pubmed/25418521 http://dx.doi.org/10.1186/s13054-014-0615-9 |
work_keys_str_mv | AT prottengeierjohannes sedationassessmentinamobileintensivecareunitaprospectivepilotstudyontherelationofclinicalsedationscalesandthebispectralindex AT moritzandreas sedationassessmentinamobileintensivecareunitaprospectivepilotstudyontherelationofclinicalsedationscalesandthebispectralindex AT heinrichsebastian sedationassessmentinamobileintensivecareunitaprospectivepilotstudyontherelationofclinicalsedationscalesandthebispectralindex AT gallchristine sedationassessmentinamobileintensivecareunitaprospectivepilotstudyontherelationofclinicalsedationscalesandthebispectralindex AT schmidtjoachim sedationassessmentinamobileintensivecareunitaprospectivepilotstudyontherelationofclinicalsedationscalesandthebispectralindex |