Cargando…

Method for validating radiobiological samples using a linear accelerator

ABSTRACT: There is an immediate need for rapid triage of the population in case of a large scale exposure to ionizing radiation. Knowing the dose absorbed by the body will allow clinicians to administer medical treatment for the best chance of recovery for the victim. In addition, today’s radiothera...

Descripción completa

Detalles Bibliográficos
Autores principales: Brengues, Muriel, Liu, David, Korn, Ronald, Zenhausern, Frederic
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4257133/
https://www.ncbi.nlm.nih.gov/pubmed/25485227
http://dx.doi.org/10.1140/epjti2
_version_ 1782347686707462144
author Brengues, Muriel
Liu, David
Korn, Ronald
Zenhausern, Frederic
author_facet Brengues, Muriel
Liu, David
Korn, Ronald
Zenhausern, Frederic
author_sort Brengues, Muriel
collection PubMed
description ABSTRACT: There is an immediate need for rapid triage of the population in case of a large scale exposure to ionizing radiation. Knowing the dose absorbed by the body will allow clinicians to administer medical treatment for the best chance of recovery for the victim. In addition, today’s radiotherapy treatment could benefit from additional information regarding the patient’s sensitivity to radiation before starting the treatment. As of today, there is no system in place to respond to this demand. This paper will describe specific procedures to mimic the effects of human exposure to ionizing radiation creating the tools for optimization of administered radiation dosimetry for radiotherapy and/or to estimate the doses of radiation received accidentally during a radiation event that could pose a danger to the public. In order to obtain irradiated biological samples to study ionizing radiation absorbed by the body, we performed ex-vivo irradiation of human blood samples using the linear accelerator (LINAC). The LINAC was implemented and calibrated for irradiating human whole blood samples. To test the calibration, a 2 Gy test run was successfully performed on a tube filled with water with an accuracy of 3% in dose distribution. To validate our technique the blood samples were ex-vivo irradiated and the results were analyzed using a gene expression assay to follow the effect of the ionizing irradiation by characterizing dose responsive biomarkers from radiobiological assays. The response of 5 genes was monitored resulting in expression increase with the dose of radiation received. The blood samples treated with the LINAC can provide effective irradiated blood samples suitable for molecular profiling to validate radiobiological measurements via the gene-expression based biodosimetry tools. PACS NUMBERS: 87.53.-j; 87.53.Bn
format Online
Article
Text
id pubmed-4257133
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-42571332014-12-05 Method for validating radiobiological samples using a linear accelerator Brengues, Muriel Liu, David Korn, Ronald Zenhausern, Frederic EPJ Tech Instrum Research Article ABSTRACT: There is an immediate need for rapid triage of the population in case of a large scale exposure to ionizing radiation. Knowing the dose absorbed by the body will allow clinicians to administer medical treatment for the best chance of recovery for the victim. In addition, today’s radiotherapy treatment could benefit from additional information regarding the patient’s sensitivity to radiation before starting the treatment. As of today, there is no system in place to respond to this demand. This paper will describe specific procedures to mimic the effects of human exposure to ionizing radiation creating the tools for optimization of administered radiation dosimetry for radiotherapy and/or to estimate the doses of radiation received accidentally during a radiation event that could pose a danger to the public. In order to obtain irradiated biological samples to study ionizing radiation absorbed by the body, we performed ex-vivo irradiation of human blood samples using the linear accelerator (LINAC). The LINAC was implemented and calibrated for irradiating human whole blood samples. To test the calibration, a 2 Gy test run was successfully performed on a tube filled with water with an accuracy of 3% in dose distribution. To validate our technique the blood samples were ex-vivo irradiated and the results were analyzed using a gene expression assay to follow the effect of the ionizing irradiation by characterizing dose responsive biomarkers from radiobiological assays. The response of 5 genes was monitored resulting in expression increase with the dose of radiation received. The blood samples treated with the LINAC can provide effective irradiated blood samples suitable for molecular profiling to validate radiobiological measurements via the gene-expression based biodosimetry tools. PACS NUMBERS: 87.53.-j; 87.53.Bn Springer Berlin Heidelberg 2014-04-29 2014 /pmc/articles/PMC4257133/ /pubmed/25485227 http://dx.doi.org/10.1140/epjti2 Text en © Brengues et al.; licensee Springer on behalf of EPJ. 2014 This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Brengues, Muriel
Liu, David
Korn, Ronald
Zenhausern, Frederic
Method for validating radiobiological samples using a linear accelerator
title Method for validating radiobiological samples using a linear accelerator
title_full Method for validating radiobiological samples using a linear accelerator
title_fullStr Method for validating radiobiological samples using a linear accelerator
title_full_unstemmed Method for validating radiobiological samples using a linear accelerator
title_short Method for validating radiobiological samples using a linear accelerator
title_sort method for validating radiobiological samples using a linear accelerator
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4257133/
https://www.ncbi.nlm.nih.gov/pubmed/25485227
http://dx.doi.org/10.1140/epjti2
work_keys_str_mv AT brenguesmuriel methodforvalidatingradiobiologicalsamplesusingalinearaccelerator
AT liudavid methodforvalidatingradiobiologicalsamplesusingalinearaccelerator
AT kornronald methodforvalidatingradiobiologicalsamplesusingalinearaccelerator
AT zenhausernfrederic methodforvalidatingradiobiologicalsamplesusingalinearaccelerator