Cargando…

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp

Background:One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff. Objective:In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using...

Descripción completa

Detalles Bibliográficos
Autores principales: Younessi Heravi, M A, Khalilzadeh, M A, Joharinia, S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4258858/
https://www.ncbi.nlm.nih.gov/pubmed/25505765
_version_ 1782347926901620736
author Younessi Heravi, M A
Khalilzadeh, M A
Joharinia, S
author_facet Younessi Heravi, M A
Khalilzadeh, M A
Joharinia, S
author_sort Younessi Heravi, M A
collection PubMed
description Background:One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff. Objective:In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference between each cardiac cycle and a relative pulse wave. Methods:Finger pulse and ECG signals in lead I were recorded by a monitoring device. The output of monitoring device wasinserted in a computer by serial network communication. A software interface (Microsoft Visual C#.NET ) was used to display and process the signals in the computer. Time difference between each cardiac cycle and pulse signal was calculated throughout R wave detection in ECG and peak of pulse signal by the software. The relation between time difference in two waves and BP was determined then the coefficients of equation were obtained in different physical situations. The results of estimating BP were compared with the results of sphygmomanometer method and the error rate was calculated. Results:In this study, 25 subjects participated among them 15 were male and 10 were female. The results showed that BP was linearly related to time difference. Average of coefficient correlation was 0.9±0.03 for systolic and 0.82±0.04 for diastolic blood pressure. The highest error percentage was calculated 8% for male and 11% for female group. Significant difference was observed between the different physical situation and arm movement changes. The relationship between time difference and age was estimated in a linear relationship with a correlation coefficient of 0.76. Conclusion: By determining linear relation values with high accuracy, BP can be measured with insignificant error. Therefore it can be suggested as a new method to measure the blood pressure continuously.
format Online
Article
Text
id pubmed-4258858
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-42588582014-12-10 Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp Younessi Heravi, M A Khalilzadeh, M A Joharinia, S J Biomed Phys Eng Original Article Background:One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff. Objective:In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference between each cardiac cycle and a relative pulse wave. Methods:Finger pulse and ECG signals in lead I were recorded by a monitoring device. The output of monitoring device wasinserted in a computer by serial network communication. A software interface (Microsoft Visual C#.NET ) was used to display and process the signals in the computer. Time difference between each cardiac cycle and pulse signal was calculated throughout R wave detection in ECG and peak of pulse signal by the software. The relation between time difference in two waves and BP was determined then the coefficients of equation were obtained in different physical situations. The results of estimating BP were compared with the results of sphygmomanometer method and the error rate was calculated. Results:In this study, 25 subjects participated among them 15 were male and 10 were female. The results showed that BP was linearly related to time difference. Average of coefficient correlation was 0.9±0.03 for systolic and 0.82±0.04 for diastolic blood pressure. The highest error percentage was calculated 8% for male and 11% for female group. Significant difference was observed between the different physical situation and arm movement changes. The relationship between time difference and age was estimated in a linear relationship with a correlation coefficient of 0.76. Conclusion: By determining linear relation values with high accuracy, BP can be measured with insignificant error. Therefore it can be suggested as a new method to measure the blood pressure continuously. Shiraz University of Medical Sciences 2014-03-08 /pmc/articles/PMC4258858/ /pubmed/25505765 Text en © 2014: Journal of Biomedical Physics and Engineering This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported License (http://creativecommons.org/licenses/by-nc/3.0/deed.en_US), which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Younessi Heravi, M A
Khalilzadeh, M A
Joharinia, S
Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp
title Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp
title_full Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp
title_fullStr Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp
title_full_unstemmed Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp
title_short Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp
title_sort continuous and cuffless blood pressure monitoring based on ecg and spo2 signals byusing microsoft visual c sharp
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4258858/
https://www.ncbi.nlm.nih.gov/pubmed/25505765
work_keys_str_mv AT younessiheravima continuousandcufflessbloodpressuremonitoringbasedonecgandspo2signalsbyusingmicrosoftvisualcsharp
AT khalilzadehma continuousandcufflessbloodpressuremonitoringbasedonecgandspo2signalsbyusingmicrosoftvisualcsharp
AT joharinias continuousandcufflessbloodpressuremonitoringbasedonecgandspo2signalsbyusingmicrosoftvisualcsharp