Cargando…

Comparison study of OCT, HRT and VF findings among normal controls and patients with pseudoexfoliation, with or without increased IOP

PURPOSE: To compare and evaluate optic nerve head (ONH) and retinal nerve fiber layer (RNFL) measurements obtained with the optical coherence tomography (OCT) and the Heidelberg retina tomography (HRT) to visual field (VF) parameters in normal and in patients with pseudoexfoliation with or without i...

Descripción completa

Detalles Bibliográficos
Autores principales: Riga, Fryni, Georgalas, Ilias, Tsikripis, Panagiotis, Papaconstantinou, Dimitrios
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4259510/
https://www.ncbi.nlm.nih.gov/pubmed/25506206
http://dx.doi.org/10.2147/OPTH.S75130
_version_ 1782348032216399872
author Riga, Fryni
Georgalas, Ilias
Tsikripis, Panagiotis
Papaconstantinou, Dimitrios
author_facet Riga, Fryni
Georgalas, Ilias
Tsikripis, Panagiotis
Papaconstantinou, Dimitrios
author_sort Riga, Fryni
collection PubMed
description PURPOSE: To compare and evaluate optic nerve head (ONH) and retinal nerve fiber layer (RNFL) measurements obtained with the optical coherence tomography (OCT) and the Heidelberg retina tomography (HRT) to visual field (VF) parameters in normal and in patients with pseudoexfoliation with or without increased intraocular pressure (IOP). METHODS: A total of 96 subjects were included in our study aged between 65 years and 78 years. The normal group consisted of 28 subjects (14 men and 14 women). Out of the total number of patients, 68 patients who showed pseudoexfoliation (21 men and 47 women) were divided into two groups. Of these, the first group had pseudoexfoliation with increased IOP and the second group showed deposits of pseudoexfoliative material without an increase in IOP. The normal controls were randomly chosen and restricted to those without any glaucomatous optic disc damages, VF defects, and an IOP <15 mmHg. All subjects were prospectively included for repeated measurements of IOP, OCT, HRT, and VFs during the same visit by the same examiner and all measurements were repeated every 3 months. RESULTS: Mean RNFL thickness measured by OCT was larger in the normal controls than in the other two groups (98.04 μm (first group) vs 75.42 μm and 97.02 μm (second group), P<0.05). Four-quadrant RNFL thickness measurements were significantly different between the normal and the group 1 (P<0.05) but not with the group 2 (P>0.05). Rim area had a mean difference of −0.44, whereas cup-to-disc ratio (C/D) showed a mean difference of 0.31, thus being significantly different between the normal and the two groups (all P<0.05). The median of the mean deviation parameter of VFs was −0.28 for the normal vs −0.32 and −0.18 for the other two groups, whereas pattern standard deviation median difference was 0.89 for the normal and 1.32 and 1.20 for the other two groups, respectively (P<0.05). CONCLUSION: Both OCT and HRT showed early ONH and RNFL changes in their parameters and did not correlate with the normal findings of the automated perimetry.
format Online
Article
Text
id pubmed-4259510
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-42595102014-12-12 Comparison study of OCT, HRT and VF findings among normal controls and patients with pseudoexfoliation, with or without increased IOP Riga, Fryni Georgalas, Ilias Tsikripis, Panagiotis Papaconstantinou, Dimitrios Clin Ophthalmol Original Research PURPOSE: To compare and evaluate optic nerve head (ONH) and retinal nerve fiber layer (RNFL) measurements obtained with the optical coherence tomography (OCT) and the Heidelberg retina tomography (HRT) to visual field (VF) parameters in normal and in patients with pseudoexfoliation with or without increased intraocular pressure (IOP). METHODS: A total of 96 subjects were included in our study aged between 65 years and 78 years. The normal group consisted of 28 subjects (14 men and 14 women). Out of the total number of patients, 68 patients who showed pseudoexfoliation (21 men and 47 women) were divided into two groups. Of these, the first group had pseudoexfoliation with increased IOP and the second group showed deposits of pseudoexfoliative material without an increase in IOP. The normal controls were randomly chosen and restricted to those without any glaucomatous optic disc damages, VF defects, and an IOP <15 mmHg. All subjects were prospectively included for repeated measurements of IOP, OCT, HRT, and VFs during the same visit by the same examiner and all measurements were repeated every 3 months. RESULTS: Mean RNFL thickness measured by OCT was larger in the normal controls than in the other two groups (98.04 μm (first group) vs 75.42 μm and 97.02 μm (second group), P<0.05). Four-quadrant RNFL thickness measurements were significantly different between the normal and the group 1 (P<0.05) but not with the group 2 (P>0.05). Rim area had a mean difference of −0.44, whereas cup-to-disc ratio (C/D) showed a mean difference of 0.31, thus being significantly different between the normal and the two groups (all P<0.05). The median of the mean deviation parameter of VFs was −0.28 for the normal vs −0.32 and −0.18 for the other two groups, whereas pattern standard deviation median difference was 0.89 for the normal and 1.32 and 1.20 for the other two groups, respectively (P<0.05). CONCLUSION: Both OCT and HRT showed early ONH and RNFL changes in their parameters and did not correlate with the normal findings of the automated perimetry. Dove Medical Press 2014-12-01 /pmc/articles/PMC4259510/ /pubmed/25506206 http://dx.doi.org/10.2147/OPTH.S75130 Text en © 2014 Riga et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Riga, Fryni
Georgalas, Ilias
Tsikripis, Panagiotis
Papaconstantinou, Dimitrios
Comparison study of OCT, HRT and VF findings among normal controls and patients with pseudoexfoliation, with or without increased IOP
title Comparison study of OCT, HRT and VF findings among normal controls and patients with pseudoexfoliation, with or without increased IOP
title_full Comparison study of OCT, HRT and VF findings among normal controls and patients with pseudoexfoliation, with or without increased IOP
title_fullStr Comparison study of OCT, HRT and VF findings among normal controls and patients with pseudoexfoliation, with or without increased IOP
title_full_unstemmed Comparison study of OCT, HRT and VF findings among normal controls and patients with pseudoexfoliation, with or without increased IOP
title_short Comparison study of OCT, HRT and VF findings among normal controls and patients with pseudoexfoliation, with or without increased IOP
title_sort comparison study of oct, hrt and vf findings among normal controls and patients with pseudoexfoliation, with or without increased iop
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4259510/
https://www.ncbi.nlm.nih.gov/pubmed/25506206
http://dx.doi.org/10.2147/OPTH.S75130
work_keys_str_mv AT rigafryni comparisonstudyofocthrtandvffindingsamongnormalcontrolsandpatientswithpseudoexfoliationwithorwithoutincreasediop
AT georgalasilias comparisonstudyofocthrtandvffindingsamongnormalcontrolsandpatientswithpseudoexfoliationwithorwithoutincreasediop
AT tsikripispanagiotis comparisonstudyofocthrtandvffindingsamongnormalcontrolsandpatientswithpseudoexfoliationwithorwithoutincreasediop
AT papaconstantinoudimitrios comparisonstudyofocthrtandvffindingsamongnormalcontrolsandpatientswithpseudoexfoliationwithorwithoutincreasediop