Cargando…

The vascular connector, design of a new device for sutureless vascular anastomosis

BACKGROUND: In recent years, several methods and new techniques have been studied and proposed for establishment of sutureless vascular anastomoses, streaming use of sutureless vascular surgery in the future. PRESENTATION OF THE HYPOTHESIS: The new vascular connector (NVC) is a hypothetical design o...

Descripción completa

Detalles Bibliográficos
Autores principales: Vokrri, Lulzim, Krasniqi, Xhavit, Qavdarbasha, Arsim, Hyseni, Nexhmi, Cinquin, Philippe, Porcu, Paolo, Sessa, Carmine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4260208/
https://www.ncbi.nlm.nih.gov/pubmed/25493096
http://dx.doi.org/10.1186/s13022-014-0008-4
_version_ 1782348142924005376
author Vokrri, Lulzim
Krasniqi, Xhavit
Qavdarbasha, Arsim
Hyseni, Nexhmi
Cinquin, Philippe
Porcu, Paolo
Sessa, Carmine
author_facet Vokrri, Lulzim
Krasniqi, Xhavit
Qavdarbasha, Arsim
Hyseni, Nexhmi
Cinquin, Philippe
Porcu, Paolo
Sessa, Carmine
author_sort Vokrri, Lulzim
collection PubMed
description BACKGROUND: In recent years, several methods and new techniques have been studied and proposed for establishment of sutureless vascular anastomoses, streaming use of sutureless vascular surgery in the future. PRESENTATION OF THE HYPOTHESIS: The new vascular connector (NVC) is a hypothetical design of a vascular device, proposed for creation and maintenance of sutureless vascular anastomosis. Implication of NVC would introduce a new device and technique in establishment of sutureless vascular anastomosis in which surgical approach is minimized and so post-operation disorders. It would eliminate need for suture; shorten clampage and operation time, consequently reducing stress for both, the surgeon and the patient. It enables the creation of vascular anastomosis fast, simple, safe, reliable, with satisfactory patency and stability of anastomosis. TESTING THE HYPOTHESIS: Efficacy of NVC needs to be evaluated in further studies, in order to be confirmed for clinical use. The effectiveness of NVC should be verified firstly in vitro and in vivo tests; and by animal experiments. The likelihood of its negative influence in thrombogenicity should be well evaluated. IMPLICATIONS OF THE HYPOTHESIS: Implication of the new vascular connector (NVC) would be of interest to both patients and the surgeon due to the following main achievements: 1) enables the creation of vascular anastomosis fast and simple, 2) significant shortening of clampage time of blood vessels and operation time-this assumption would be followed by reduced risk of operative and post-operative complications and length of hospital stay or admission to Intensive care unit, 3) safe and reliable, 4) compatible with any blood vessel and standard vascular graft, 5) using the NVC we will reduce in minimum need for replaced blood volume, 6) reduces the cost of treatment. It is anticipated that the NVC would provide shorter operation time and least operative and post-operative complications in creation of sutureless vascular anastomosis.
format Online
Article
Text
id pubmed-4260208
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42602082014-12-09 The vascular connector, design of a new device for sutureless vascular anastomosis Vokrri, Lulzim Krasniqi, Xhavit Qavdarbasha, Arsim Hyseni, Nexhmi Cinquin, Philippe Porcu, Paolo Sessa, Carmine Ann Surg Innov Res Hypothesis BACKGROUND: In recent years, several methods and new techniques have been studied and proposed for establishment of sutureless vascular anastomoses, streaming use of sutureless vascular surgery in the future. PRESENTATION OF THE HYPOTHESIS: The new vascular connector (NVC) is a hypothetical design of a vascular device, proposed for creation and maintenance of sutureless vascular anastomosis. Implication of NVC would introduce a new device and technique in establishment of sutureless vascular anastomosis in which surgical approach is minimized and so post-operation disorders. It would eliminate need for suture; shorten clampage and operation time, consequently reducing stress for both, the surgeon and the patient. It enables the creation of vascular anastomosis fast, simple, safe, reliable, with satisfactory patency and stability of anastomosis. TESTING THE HYPOTHESIS: Efficacy of NVC needs to be evaluated in further studies, in order to be confirmed for clinical use. The effectiveness of NVC should be verified firstly in vitro and in vivo tests; and by animal experiments. The likelihood of its negative influence in thrombogenicity should be well evaluated. IMPLICATIONS OF THE HYPOTHESIS: Implication of the new vascular connector (NVC) would be of interest to both patients and the surgeon due to the following main achievements: 1) enables the creation of vascular anastomosis fast and simple, 2) significant shortening of clampage time of blood vessels and operation time-this assumption would be followed by reduced risk of operative and post-operative complications and length of hospital stay or admission to Intensive care unit, 3) safe and reliable, 4) compatible with any blood vessel and standard vascular graft, 5) using the NVC we will reduce in minimum need for replaced blood volume, 6) reduces the cost of treatment. It is anticipated that the NVC would provide shorter operation time and least operative and post-operative complications in creation of sutureless vascular anastomosis. BioMed Central 2014-11-22 /pmc/articles/PMC4260208/ /pubmed/25493096 http://dx.doi.org/10.1186/s13022-014-0008-4 Text en © Vokrri et al.; licensee BioMed Central Ltd. 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Hypothesis
Vokrri, Lulzim
Krasniqi, Xhavit
Qavdarbasha, Arsim
Hyseni, Nexhmi
Cinquin, Philippe
Porcu, Paolo
Sessa, Carmine
The vascular connector, design of a new device for sutureless vascular anastomosis
title The vascular connector, design of a new device for sutureless vascular anastomosis
title_full The vascular connector, design of a new device for sutureless vascular anastomosis
title_fullStr The vascular connector, design of a new device for sutureless vascular anastomosis
title_full_unstemmed The vascular connector, design of a new device for sutureless vascular anastomosis
title_short The vascular connector, design of a new device for sutureless vascular anastomosis
title_sort vascular connector, design of a new device for sutureless vascular anastomosis
topic Hypothesis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4260208/
https://www.ncbi.nlm.nih.gov/pubmed/25493096
http://dx.doi.org/10.1186/s13022-014-0008-4
work_keys_str_mv AT vokrrilulzim thevascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT krasniqixhavit thevascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT qavdarbashaarsim thevascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT hyseninexhmi thevascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT cinquinphilippe thevascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT porcupaolo thevascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT sessacarmine thevascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT vokrrilulzim vascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT krasniqixhavit vascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT qavdarbashaarsim vascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT hyseninexhmi vascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT cinquinphilippe vascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT porcupaolo vascularconnectordesignofanewdeviceforsuturelessvascularanastomosis
AT sessacarmine vascularconnectordesignofanewdeviceforsuturelessvascularanastomosis