Cargando…

In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology

BACKGROUND: The evaluation of any new cardiac valvular prosthesis should go beyond the classical morbidity and mortality rates and involve hemodynamic assessment. As a proof of concept, the objective of this study was to characterise for the first time the hemodynamics and the blood flow profiles at...

Descripción completa

Detalles Bibliográficos
Autores principales: Kidher, Emaddin, Cheng, Zhuo, Jarral, Omar A, O’Regan, Declan P, Xu, Xiao Yun, Athanasiou, Thanos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4263057/
https://www.ncbi.nlm.nih.gov/pubmed/25488105
http://dx.doi.org/10.1186/s13019-014-0193-6
_version_ 1782348499857178624
author Kidher, Emaddin
Cheng, Zhuo
Jarral, Omar A
O’Regan, Declan P
Xu, Xiao Yun
Athanasiou, Thanos
author_facet Kidher, Emaddin
Cheng, Zhuo
Jarral, Omar A
O’Regan, Declan P
Xu, Xiao Yun
Athanasiou, Thanos
author_sort Kidher, Emaddin
collection PubMed
description BACKGROUND: The evaluation of any new cardiac valvular prosthesis should go beyond the classical morbidity and mortality rates and involve hemodynamic assessment. As a proof of concept, the objective of this study was to characterise for the first time the hemodynamics and the blood flow profiles at the aortic root in patients implanted with BioValsalva™ composite valve-conduit using comprehensive MRI and computer technologies. METHODS: Four male patients implanted with BioValsalva™ and 2 age-matched normal controls (NC) underwent cardiac magnetic resonance imaging (MRI). Phase-contrast imaging with velocity-mapping in 3 orthogonal directions was performed at the level of the aortic root and descending thoracic aorta. Computational fluid dynamic (CFD) simulations were performed for all the subjects with patient-specific flow information derived from phase-contrast MR data. RESULTS: The maximum and mean flow rates throughout the cardiac cycle at the aortic root level were very comparable between NC and BioValsalva™ patients (541 ± 199 vs. 567 ± 75 ml/s) and (95 ± 46 vs. 96 ± 10 ml/s), respectively. The maximum velocity (cm/s) was higher in patients (314 ± 49 vs. 223 ± 20; P = 0.06) due to relatively smaller effective orifice area (EOA), 2.99 ± 0.47 vs. 4.40 ± 0.24 cm(2) (P = 0.06), however, the BioValsalva™ EOA was comparable to other reported prosthesis. The cross-sectional area and maximum diameter at the root were comparable between the two groups. BioValsalva™ conduit was stiffer than the native aortic wall, compliance (mm(2) • mmHg(−1) • 10(−3)) values were (12.6 ± 4.2 vs 25.3 ± 0.4.; P = 0.06). The maximum time-averaged wall shear stress (Pa), at the ascending aorta was equivalent between the two groups, 17.17 ± 2.7 (NC) vs. 17.33 ± 4.7 (BioValsalva™ ). Flow streamlines at the root and ascending aorta were also similar between the two groups apart from a degree of helical flow that occurs at the outer curvature at the angle developed near the suture line. CONCLUSIONS: BioValsalva™ composite valve-conduit prosthesis is potentially comparable to native aortic root in structural design and in many hemodynamic parameters, although it is stiffer. Surgeons should pay more attention to the surgical technique to maximise the reestablishment of normal smooth aortic curvature geometry to prevent unfavourable flow characteristics. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13019-014-0193-6) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4263057
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42630572014-12-12 In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology Kidher, Emaddin Cheng, Zhuo Jarral, Omar A O’Regan, Declan P Xu, Xiao Yun Athanasiou, Thanos J Cardiothorac Surg Research Article BACKGROUND: The evaluation of any new cardiac valvular prosthesis should go beyond the classical morbidity and mortality rates and involve hemodynamic assessment. As a proof of concept, the objective of this study was to characterise for the first time the hemodynamics and the blood flow profiles at the aortic root in patients implanted with BioValsalva™ composite valve-conduit using comprehensive MRI and computer technologies. METHODS: Four male patients implanted with BioValsalva™ and 2 age-matched normal controls (NC) underwent cardiac magnetic resonance imaging (MRI). Phase-contrast imaging with velocity-mapping in 3 orthogonal directions was performed at the level of the aortic root and descending thoracic aorta. Computational fluid dynamic (CFD) simulations were performed for all the subjects with patient-specific flow information derived from phase-contrast MR data. RESULTS: The maximum and mean flow rates throughout the cardiac cycle at the aortic root level were very comparable between NC and BioValsalva™ patients (541 ± 199 vs. 567 ± 75 ml/s) and (95 ± 46 vs. 96 ± 10 ml/s), respectively. The maximum velocity (cm/s) was higher in patients (314 ± 49 vs. 223 ± 20; P = 0.06) due to relatively smaller effective orifice area (EOA), 2.99 ± 0.47 vs. 4.40 ± 0.24 cm(2) (P = 0.06), however, the BioValsalva™ EOA was comparable to other reported prosthesis. The cross-sectional area and maximum diameter at the root were comparable between the two groups. BioValsalva™ conduit was stiffer than the native aortic wall, compliance (mm(2) • mmHg(−1) • 10(−3)) values were (12.6 ± 4.2 vs 25.3 ± 0.4.; P = 0.06). The maximum time-averaged wall shear stress (Pa), at the ascending aorta was equivalent between the two groups, 17.17 ± 2.7 (NC) vs. 17.33 ± 4.7 (BioValsalva™ ). Flow streamlines at the root and ascending aorta were also similar between the two groups apart from a degree of helical flow that occurs at the outer curvature at the angle developed near the suture line. CONCLUSIONS: BioValsalva™ composite valve-conduit prosthesis is potentially comparable to native aortic root in structural design and in many hemodynamic parameters, although it is stiffer. Surgeons should pay more attention to the surgical technique to maximise the reestablishment of normal smooth aortic curvature geometry to prevent unfavourable flow characteristics. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13019-014-0193-6) contains supplementary material, which is available to authorized users. BioMed Central 2014-12-09 /pmc/articles/PMC4263057/ /pubmed/25488105 http://dx.doi.org/10.1186/s13019-014-0193-6 Text en © Kidher et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Kidher, Emaddin
Cheng, Zhuo
Jarral, Omar A
O’Regan, Declan P
Xu, Xiao Yun
Athanasiou, Thanos
In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology
title In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology
title_full In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology
title_fullStr In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology
title_full_unstemmed In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology
title_short In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology
title_sort in-vivo assessment of the morphology and hemodynamic functions of the biovalsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4263057/
https://www.ncbi.nlm.nih.gov/pubmed/25488105
http://dx.doi.org/10.1186/s13019-014-0193-6
work_keys_str_mv AT kidheremaddin invivoassessmentofthemorphologyandhemodynamicfunctionsofthebiovalsalvacompositevalveconduitgraftusingcardiacmagneticresonanceimagingandcomputationalmodellingtechnology
AT chengzhuo invivoassessmentofthemorphologyandhemodynamicfunctionsofthebiovalsalvacompositevalveconduitgraftusingcardiacmagneticresonanceimagingandcomputationalmodellingtechnology
AT jarralomara invivoassessmentofthemorphologyandhemodynamicfunctionsofthebiovalsalvacompositevalveconduitgraftusingcardiacmagneticresonanceimagingandcomputationalmodellingtechnology
AT oregandeclanp invivoassessmentofthemorphologyandhemodynamicfunctionsofthebiovalsalvacompositevalveconduitgraftusingcardiacmagneticresonanceimagingandcomputationalmodellingtechnology
AT xuxiaoyun invivoassessmentofthemorphologyandhemodynamicfunctionsofthebiovalsalvacompositevalveconduitgraftusingcardiacmagneticresonanceimagingandcomputationalmodellingtechnology
AT athanasiouthanos invivoassessmentofthemorphologyandhemodynamicfunctionsofthebiovalsalvacompositevalveconduitgraftusingcardiacmagneticresonanceimagingandcomputationalmodellingtechnology