Cargando…

A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays

We demonstrate a fluorescence lateral flow system that has excellent sensitivity and wide dynamic range. The illumination system utilizes an LED, plastic lenses and plastic and colored glass filters for the excitation and emission light. Images are collected on an iPhone 4. Several fluorescent dyes...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Linda G., Nordman, Eric S., Johnson, Martin D., Oldham, Mark F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4263565/
https://www.ncbi.nlm.nih.gov/pubmed/25586412
http://dx.doi.org/10.3390/bios3040360
_version_ 1782348598244016128
author Lee, Linda G.
Nordman, Eric S.
Johnson, Martin D.
Oldham, Mark F.
author_facet Lee, Linda G.
Nordman, Eric S.
Johnson, Martin D.
Oldham, Mark F.
author_sort Lee, Linda G.
collection PubMed
description We demonstrate a fluorescence lateral flow system that has excellent sensitivity and wide dynamic range. The illumination system utilizes an LED, plastic lenses and plastic and colored glass filters for the excitation and emission light. Images are collected on an iPhone 4. Several fluorescent dyes with long Stokes shifts were evaluated for their signal and nonspecific binding in lateral flow. A wide range of values for the ratio of signal to nonspecific binding was found, from 50 for R-phycoerythrin (R-PE) to 0.15 for Brilliant Violet 605. The long Stokes shift of R-PE allowed the use of inexpensive plastic filters rather than costly interference filters to block the LED light. Fluorescence detection with R-PE and absorbance detection with colloidal gold were directly compared in lateral flow using biotinylated bovine serum albumen (BSA) as the analyte. Fluorescence provided linear data over a range of 0.4–4,000 ng/mL with a 1,000-fold signal change while colloidal gold provided non-linear data over a range of 16–4,000 ng/mL with a 10-fold signal change. A comparison using human chorionic gonadotropin (hCG) as the analyte showed a similar advantage in the fluorescent system. We believe our inexpensive yet high-performance platform will be useful for providing quantitative and sensitive detection in a point-of-care setting.
format Online
Article
Text
id pubmed-4263565
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-42635652015-01-13 A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays Lee, Linda G. Nordman, Eric S. Johnson, Martin D. Oldham, Mark F. Biosensors (Basel) Article We demonstrate a fluorescence lateral flow system that has excellent sensitivity and wide dynamic range. The illumination system utilizes an LED, plastic lenses and plastic and colored glass filters for the excitation and emission light. Images are collected on an iPhone 4. Several fluorescent dyes with long Stokes shifts were evaluated for their signal and nonspecific binding in lateral flow. A wide range of values for the ratio of signal to nonspecific binding was found, from 50 for R-phycoerythrin (R-PE) to 0.15 for Brilliant Violet 605. The long Stokes shift of R-PE allowed the use of inexpensive plastic filters rather than costly interference filters to block the LED light. Fluorescence detection with R-PE and absorbance detection with colloidal gold were directly compared in lateral flow using biotinylated bovine serum albumen (BSA) as the analyte. Fluorescence provided linear data over a range of 0.4–4,000 ng/mL with a 1,000-fold signal change while colloidal gold provided non-linear data over a range of 16–4,000 ng/mL with a 10-fold signal change. A comparison using human chorionic gonadotropin (hCG) as the analyte showed a similar advantage in the fluorescent system. We believe our inexpensive yet high-performance platform will be useful for providing quantitative and sensitive detection in a point-of-care setting. MDPI 2013-10-21 /pmc/articles/PMC4263565/ /pubmed/25586412 http://dx.doi.org/10.3390/bios3040360 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. http://creativecommons.org/licenses/by/3.0/ This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Lee, Linda G.
Nordman, Eric S.
Johnson, Martin D.
Oldham, Mark F.
A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays
title A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays
title_full A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays
title_fullStr A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays
title_full_unstemmed A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays
title_short A Low-Cost, High-Performance System for Fluorescence Lateral Flow Assays
title_sort low-cost, high-performance system for fluorescence lateral flow assays
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4263565/
https://www.ncbi.nlm.nih.gov/pubmed/25586412
http://dx.doi.org/10.3390/bios3040360
work_keys_str_mv AT leelindag alowcosthighperformancesystemforfluorescencelateralflowassays
AT nordmanerics alowcosthighperformancesystemforfluorescencelateralflowassays
AT johnsonmartind alowcosthighperformancesystemforfluorescencelateralflowassays
AT oldhammarkf alowcosthighperformancesystemforfluorescencelateralflowassays
AT leelindag lowcosthighperformancesystemforfluorescencelateralflowassays
AT nordmanerics lowcosthighperformancesystemforfluorescencelateralflowassays
AT johnsonmartind lowcosthighperformancesystemforfluorescencelateralflowassays
AT oldhammarkf lowcosthighperformancesystemforfluorescencelateralflowassays