Cargando…

Evaluation of short-TE (1)H MRSI for quantification of metabolites in the prostate

Back-to-back (1)H MRSI scans, using an endorectal and phased-array coil combination, were performed on 18 low-risk patients with prostate cancer at 3 T, employing TEs of 32 and 100 ms in order to compare metabolite visualization at each TE. Outer-volume suppression of lipid signals was performed usi...

Descripción completa

Detalles Bibliográficos
Autores principales: Basharat, Meer, Jafar, Maysam, deSouza, Nandita M, Payne, Geoffrey S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BlackWell Publishing Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4265190/
https://www.ncbi.nlm.nih.gov/pubmed/24519849
http://dx.doi.org/10.1002/nbm.3082
_version_ 1782348842268622848
author Basharat, Meer
Jafar, Maysam
deSouza, Nandita M
Payne, Geoffrey S
author_facet Basharat, Meer
Jafar, Maysam
deSouza, Nandita M
Payne, Geoffrey S
author_sort Basharat, Meer
collection PubMed
description Back-to-back (1)H MRSI scans, using an endorectal and phased-array coil combination, were performed on 18 low-risk patients with prostate cancer at 3 T, employing TEs of 32 and 100 ms in order to compare metabolite visualization at each TE. Outer-volume suppression of lipid signals was performed using regional saturation (REST) slabs and the quantification of spectra at both TEs was achieved with the quantitation using quantum estimation (QUEST) routine. Metabolite nulling experiments in an additional five patients found that there were negligible macromolecule background signals in prostate spectra at TE = 32 ms. Metabolite visibility was judged using the criterion Cramér–Rao lower bound (CRLB)/amplitude < 20%, and metabolite concentrations were corrected for relaxation effects and referenced to the data acquired in corresponding water-unsuppressed MRSI scans. For the first time, the prostate metabolites spermine and myo-inositol were quantified individually in vivo, together with citrate, choline and creatine. All five metabolite visibilities were higher in TE = 32 ms MRSI than in TE = 100 ms MRSI. At TE = 32 ms, citrate was visible in 99.0% of lipid-free spectra, whereas, at TE = 100 ms, no metabolite simulation of citrate matched the in vivo peaks. Spermine, choline and creatine were visualised separately in 30.4% more spectra at TE = 32 ms than at TE = 100 ms, and myo-inositol in 72.5% more spectra. T(2) values were calculated for spermine (53 ± 16 ms), choline (62 ± 17 ms) and myo-inositol (90 ± 48 ms). Data from the TE = 32 ms spectra showed that the concentrations of citrate and spermine secretions were positively correlated in both the peripheral zone and central gland (R(2) = 0.73 and R(2) = 0.43, respectively), and that the citrate content was significantly higher in the former at 64 ± 22 mm than in the latter at 32 ± 16 mm (p = 0.01). However, lipid contamination at TE = 32 ms was substantial; therefore, to make clinical use of the greater visualisation of prostate metabolites at TE = 32 ms rather than at TE = 100 ms, three-dimensional MRSI at TE = 32 ms with effective lipid suppression must be implemented.
format Online
Article
Text
id pubmed-4265190
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BlackWell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-42651902014-12-19 Evaluation of short-TE (1)H MRSI for quantification of metabolites in the prostate Basharat, Meer Jafar, Maysam deSouza, Nandita M Payne, Geoffrey S NMR Biomed Research Articles Back-to-back (1)H MRSI scans, using an endorectal and phased-array coil combination, were performed on 18 low-risk patients with prostate cancer at 3 T, employing TEs of 32 and 100 ms in order to compare metabolite visualization at each TE. Outer-volume suppression of lipid signals was performed using regional saturation (REST) slabs and the quantification of spectra at both TEs was achieved with the quantitation using quantum estimation (QUEST) routine. Metabolite nulling experiments in an additional five patients found that there were negligible macromolecule background signals in prostate spectra at TE = 32 ms. Metabolite visibility was judged using the criterion Cramér–Rao lower bound (CRLB)/amplitude < 20%, and metabolite concentrations were corrected for relaxation effects and referenced to the data acquired in corresponding water-unsuppressed MRSI scans. For the first time, the prostate metabolites spermine and myo-inositol were quantified individually in vivo, together with citrate, choline and creatine. All five metabolite visibilities were higher in TE = 32 ms MRSI than in TE = 100 ms MRSI. At TE = 32 ms, citrate was visible in 99.0% of lipid-free spectra, whereas, at TE = 100 ms, no metabolite simulation of citrate matched the in vivo peaks. Spermine, choline and creatine were visualised separately in 30.4% more spectra at TE = 32 ms than at TE = 100 ms, and myo-inositol in 72.5% more spectra. T(2) values were calculated for spermine (53 ± 16 ms), choline (62 ± 17 ms) and myo-inositol (90 ± 48 ms). Data from the TE = 32 ms spectra showed that the concentrations of citrate and spermine secretions were positively correlated in both the peripheral zone and central gland (R(2) = 0.73 and R(2) = 0.43, respectively), and that the citrate content was significantly higher in the former at 64 ± 22 mm than in the latter at 32 ± 16 mm (p = 0.01). However, lipid contamination at TE = 32 ms was substantial; therefore, to make clinical use of the greater visualisation of prostate metabolites at TE = 32 ms rather than at TE = 100 ms, three-dimensional MRSI at TE = 32 ms with effective lipid suppression must be implemented. BlackWell Publishing Ltd 2014-04 2014-02-12 /pmc/articles/PMC4265190/ /pubmed/24519849 http://dx.doi.org/10.1002/nbm.3082 Text en © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd. http://creativecommons.org/licenses/by/3.0/ This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Basharat, Meer
Jafar, Maysam
deSouza, Nandita M
Payne, Geoffrey S
Evaluation of short-TE (1)H MRSI for quantification of metabolites in the prostate
title Evaluation of short-TE (1)H MRSI for quantification of metabolites in the prostate
title_full Evaluation of short-TE (1)H MRSI for quantification of metabolites in the prostate
title_fullStr Evaluation of short-TE (1)H MRSI for quantification of metabolites in the prostate
title_full_unstemmed Evaluation of short-TE (1)H MRSI for quantification of metabolites in the prostate
title_short Evaluation of short-TE (1)H MRSI for quantification of metabolites in the prostate
title_sort evaluation of short-te (1)h mrsi for quantification of metabolites in the prostate
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4265190/
https://www.ncbi.nlm.nih.gov/pubmed/24519849
http://dx.doi.org/10.1002/nbm.3082
work_keys_str_mv AT basharatmeer evaluationofshortte1hmrsiforquantificationofmetabolitesintheprostate
AT jafarmaysam evaluationofshortte1hmrsiforquantificationofmetabolitesintheprostate
AT desouzananditam evaluationofshortte1hmrsiforquantificationofmetabolitesintheprostate
AT paynegeoffreys evaluationofshortte1hmrsiforquantificationofmetabolitesintheprostate