Cargando…

The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions

BACKGROUND: Proton resonance frequency shift (PRFS) magnetic resonance (MR) thermometry exploits the local magnetic field changes induced by the temperature dependence of the electron screening constant of water protons. Any other local magnetic field changes will therefore translate into incorrect...

Descripción completa

Detalles Bibliográficos
Autores principales: Hijnen, Nicole M, Elevelt, Aaldert, Pikkemaat, Jeroen, Bos, Clemens, Bartels, Lambertus W, Grüll, Holger
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4265976/
https://www.ncbi.nlm.nih.gov/pubmed/25516799
http://dx.doi.org/10.1186/2050-5736-1-8
_version_ 1782348956400877568
author Hijnen, Nicole M
Elevelt, Aaldert
Pikkemaat, Jeroen
Bos, Clemens
Bartels, Lambertus W
Grüll, Holger
author_facet Hijnen, Nicole M
Elevelt, Aaldert
Pikkemaat, Jeroen
Bos, Clemens
Bartels, Lambertus W
Grüll, Holger
author_sort Hijnen, Nicole M
collection PubMed
description BACKGROUND: Proton resonance frequency shift (PRFS) magnetic resonance (MR) thermometry exploits the local magnetic field changes induced by the temperature dependence of the electron screening constant of water protons. Any other local magnetic field changes will therefore translate into incorrect temperature readings and need to be considered accordingly. Here, we investigated the susceptibility changes induced by the inflow and presence of a paramagnetic MR contrast agent and their implications on PRFS thermometry. METHODS: Phantom measurements were performed to demonstrate the effect of sudden gadopentetate dimeglumine (Gd-DTPA) inflow on the phase shift measured using a PRFS thermometry sequence on a clinical 3 T magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) system. By proton nuclear magnetic resonance spectroscopy, the temperature dependence of the Gd-DTPA susceptibility was measured, as well as the effect of liposomal encapsulation and release on the bulk magnetic susceptibility of Gd-DTPA. In vivo studies were carried out to measure the temperature error induced in a rat hind leg muscle upon intravenous Gd-DTPA injection. RESULTS: The phantom study showed a significant phase shift inside the phantom of 0.6 ± 0.2 radians (mean ± standard deviation) upon Gd-DTPA injection (1.0 mM, clinically relevant amount). A Gd-DTPA-induced magnetic susceptibility shift of Δχ(Gd-DTPA) = 0.109 ppm/mM was measured in a cylinder parallel to the main magnetic field at 37°C. The temperature dependence of the susceptibility shift showed dΔχ(Gd-DTPA)/dT = -0.00038 ± 0.00008 ppm/mM/°C. No additional susceptibility effect was measured upon Gd release from paramagnetic liposomes. In vivo, intravenous Gd-DTPA injection resulted in a perceived temperature change of 2.0°C ± 0.1°C at the center of the hind leg muscle. CONCLUSIONS: The use of a paramagnetic MR contrast agent prior to MR-HIFU treatment may influence the accuracy of the PRFS MR thermometry. Depending on the treatment workflow, Gd-induced temperature errors ranging between -4°C and +3°C can be expected. Longer waiting time between contrast agent injection and treatment, as well as shortening the ablation duration by increasing the sonication power, will minimize the Gd influence. Compensation for the phase changes induced by the changing Gd presence is difficult as the magnetic field changes are arising nonlocally in the surroundings of the susceptibility change.
format Online
Article
Text
id pubmed-4265976
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42659762014-12-16 The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions Hijnen, Nicole M Elevelt, Aaldert Pikkemaat, Jeroen Bos, Clemens Bartels, Lambertus W Grüll, Holger J Ther Ultrasound Research BACKGROUND: Proton resonance frequency shift (PRFS) magnetic resonance (MR) thermometry exploits the local magnetic field changes induced by the temperature dependence of the electron screening constant of water protons. Any other local magnetic field changes will therefore translate into incorrect temperature readings and need to be considered accordingly. Here, we investigated the susceptibility changes induced by the inflow and presence of a paramagnetic MR contrast agent and their implications on PRFS thermometry. METHODS: Phantom measurements were performed to demonstrate the effect of sudden gadopentetate dimeglumine (Gd-DTPA) inflow on the phase shift measured using a PRFS thermometry sequence on a clinical 3 T magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) system. By proton nuclear magnetic resonance spectroscopy, the temperature dependence of the Gd-DTPA susceptibility was measured, as well as the effect of liposomal encapsulation and release on the bulk magnetic susceptibility of Gd-DTPA. In vivo studies were carried out to measure the temperature error induced in a rat hind leg muscle upon intravenous Gd-DTPA injection. RESULTS: The phantom study showed a significant phase shift inside the phantom of 0.6 ± 0.2 radians (mean ± standard deviation) upon Gd-DTPA injection (1.0 mM, clinically relevant amount). A Gd-DTPA-induced magnetic susceptibility shift of Δχ(Gd-DTPA) = 0.109 ppm/mM was measured in a cylinder parallel to the main magnetic field at 37°C. The temperature dependence of the susceptibility shift showed dΔχ(Gd-DTPA)/dT = -0.00038 ± 0.00008 ppm/mM/°C. No additional susceptibility effect was measured upon Gd release from paramagnetic liposomes. In vivo, intravenous Gd-DTPA injection resulted in a perceived temperature change of 2.0°C ± 0.1°C at the center of the hind leg muscle. CONCLUSIONS: The use of a paramagnetic MR contrast agent prior to MR-HIFU treatment may influence the accuracy of the PRFS MR thermometry. Depending on the treatment workflow, Gd-induced temperature errors ranging between -4°C and +3°C can be expected. Longer waiting time between contrast agent injection and treatment, as well as shortening the ablation duration by increasing the sonication power, will minimize the Gd influence. Compensation for the phase changes induced by the changing Gd presence is difficult as the magnetic field changes are arising nonlocally in the surroundings of the susceptibility change. BioMed Central 2013-06-04 /pmc/articles/PMC4265976/ /pubmed/25516799 http://dx.doi.org/10.1186/2050-5736-1-8 Text en Copyright © 2013 Hijnen et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Hijnen, Nicole M
Elevelt, Aaldert
Pikkemaat, Jeroen
Bos, Clemens
Bartels, Lambertus W
Grüll, Holger
The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions
title The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions
title_full The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions
title_fullStr The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions
title_full_unstemmed The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions
title_short The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions
title_sort magnetic susceptibility effect of gadolinium-based contrast agents on prfs-based mr thermometry during thermal interventions
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4265976/
https://www.ncbi.nlm.nih.gov/pubmed/25516799
http://dx.doi.org/10.1186/2050-5736-1-8
work_keys_str_mv AT hijnennicolem themagneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT eleveltaaldert themagneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT pikkemaatjeroen themagneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT bosclemens themagneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT bartelslambertusw themagneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT grullholger themagneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT hijnennicolem magneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT eleveltaaldert magneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT pikkemaatjeroen magneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT bosclemens magneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT bartelslambertusw magneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions
AT grullholger magneticsusceptibilityeffectofgadoliniumbasedcontrastagentsonprfsbasedmrthermometryduringthermalinterventions