Cargando…

Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure

BACKGROUND: This is a first-in-human study to determine the efficacy and tolerability of a new method of treating glaucoma using a low-power, low-frequency, focused therapeutic ultrasound for glaucoma (TUG) device designed to trigger an inflammatory reaction in the anterior chamber angle and trabecu...

Descripción completa

Detalles Bibliográficos
Autores principales: Schwartz, Donald, Samples, John, Korosteleva, Olga
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4266006/
https://www.ncbi.nlm.nih.gov/pubmed/25512870
http://dx.doi.org/10.1186/2050-5736-2-15
_version_ 1782348962266611712
author Schwartz, Donald
Samples, John
Korosteleva, Olga
author_facet Schwartz, Donald
Samples, John
Korosteleva, Olga
author_sort Schwartz, Donald
collection PubMed
description BACKGROUND: This is a first-in-human study to determine the efficacy and tolerability of a new method of treating glaucoma using a low-power, low-frequency, focused therapeutic ultrasound for glaucoma (TUG) device designed to trigger an inflammatory reaction in the anterior chamber angle and trabecular meshwork to enhance outflow. The use of the device is anticipated for mild or moderate open-angle glaucoma as an enhancement to outflow. METHODS: In a two-branch clinical trial, a total of 26 primary open-angle glaucoma patients underwent a procedure consisting of the external application of the TUG device. In branch 1, nine of these patients were naïve to pharmaceutical treatment or had been off of medication for over 6 months. In branch 2, 17 patients were treated after a medication washout period. All patients in the study were followed for 12 months. RESULTS: In branch 1, there was a decrease in intraocular pressure averaging over 20% lasting at least a year in 74% of the eyes with non-normotensive open-angle glaucoma. In branch 2, an average of two visits while on medication provided the comparison intraocular pressure (IOP) to the effect of the TUG treatment after washout. It was seen that the intraocular pressure over the year post-treatment was equal to or better than the pharmaceutical control in close to 80% of measurements. CONCLUSION: A novel device for lowering intraocular pressure is described with a potential for adding to our armamentarium for treating glaucoma. This is a small cohort study which indicates beneficial trends. TRIAL REGISTRATION NUMBER: The study was a registered clinical trial, #ISRCTN50904302.
format Online
Article
Text
id pubmed-4266006
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42660062014-12-16 Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure Schwartz, Donald Samples, John Korosteleva, Olga J Ther Ultrasound Research BACKGROUND: This is a first-in-human study to determine the efficacy and tolerability of a new method of treating glaucoma using a low-power, low-frequency, focused therapeutic ultrasound for glaucoma (TUG) device designed to trigger an inflammatory reaction in the anterior chamber angle and trabecular meshwork to enhance outflow. The use of the device is anticipated for mild or moderate open-angle glaucoma as an enhancement to outflow. METHODS: In a two-branch clinical trial, a total of 26 primary open-angle glaucoma patients underwent a procedure consisting of the external application of the TUG device. In branch 1, nine of these patients were naïve to pharmaceutical treatment or had been off of medication for over 6 months. In branch 2, 17 patients were treated after a medication washout period. All patients in the study were followed for 12 months. RESULTS: In branch 1, there was a decrease in intraocular pressure averaging over 20% lasting at least a year in 74% of the eyes with non-normotensive open-angle glaucoma. In branch 2, an average of two visits while on medication provided the comparison intraocular pressure (IOP) to the effect of the TUG treatment after washout. It was seen that the intraocular pressure over the year post-treatment was equal to or better than the pharmaceutical control in close to 80% of measurements. CONCLUSION: A novel device for lowering intraocular pressure is described with a potential for adding to our armamentarium for treating glaucoma. This is a small cohort study which indicates beneficial trends. TRIAL REGISTRATION NUMBER: The study was a registered clinical trial, #ISRCTN50904302. BioMed Central 2014-09-26 /pmc/articles/PMC4266006/ /pubmed/25512870 http://dx.doi.org/10.1186/2050-5736-2-15 Text en Copyright © 2014 Schwartz et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Schwartz, Donald
Samples, John
Korosteleva, Olga
Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure
title Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure
title_full Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure
title_fullStr Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure
title_full_unstemmed Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure
title_short Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure
title_sort therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4266006/
https://www.ncbi.nlm.nih.gov/pubmed/25512870
http://dx.doi.org/10.1186/2050-5736-2-15
work_keys_str_mv AT schwartzdonald therapeuticultrasoundforglaucomaclinicaluseofalowfrequencylowpowerultrasounddeviceforloweringintraocularpressure
AT samplesjohn therapeuticultrasoundforglaucomaclinicaluseofalowfrequencylowpowerultrasounddeviceforloweringintraocularpressure
AT korostelevaolga therapeuticultrasoundforglaucomaclinicaluseofalowfrequencylowpowerultrasounddeviceforloweringintraocularpressure