Cargando…

Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs

PURPOSE: Tacks and sutures ensure a strong fixation of meshes, but they can be associated with pain and discomfort. Less invasive methods are now available. Three fixation modalities were compared: the ProGrip™ laparoscopic self-fixating mesh; the fibrin glue Tisseel™ with Bard™ Soft Mesh; and the S...

Descripción completa

Detalles Bibliográficos
Autores principales: Guérin, Gaëtan, Bourges, Xavier, Turquier, Frédéric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4267587/
https://www.ncbi.nlm.nih.gov/pubmed/25525396
http://dx.doi.org/10.2147/MDER.S71035
_version_ 1782349161871441920
author Guérin, Gaëtan
Bourges, Xavier
Turquier, Frédéric
author_facet Guérin, Gaëtan
Bourges, Xavier
Turquier, Frédéric
author_sort Guérin, Gaëtan
collection PubMed
description PURPOSE: Tacks and sutures ensure a strong fixation of meshes, but they can be associated with pain and discomfort. Less invasive methods are now available. Three fixation modalities were compared: the ProGrip™ laparoscopic self-fixating mesh; the fibrin glue Tisseel™ with Bard™ Soft Mesh; and the SorbaFix™ absorbable fixation system with Bard™ Soft Mesh. MATERIALS AND METHODS: Meshes (6 cm ×6 cm) were implanted in the preperitoneal space of swine. Samples were explanted 24 hours after surgery. Centered defects were created, and samples (either ten or eleven per fixation type) were loaded in a pressure chamber. For each sample, the pressure, the mesh displacement through the defect, and the measurements of the contact area were recorded. RESULTS: At all pressures tested, the ProGrip™ laparoscopic self-fixating mesh both exhibited a significantly lower displacement through the defect and retained a significantly higher percentage of its initial contact area than either the Bard™ Soft Mesh with Tisseel™ system or the Bard™ Soft Mesh with SorbaFix™ absorbable fixation system. Dislocations occurred with the Bard™ Soft Mesh with Tisseel™ system and with the Bard™ Soft Mesh with SorbaFix™ absorbable fixation system at physiological pressure (,225 mmHg). No dislocation was recorded for the ProGrip™ laparoscopic self-fixating mesh. CONCLUSION: At 24 hours after implantation, the mechanical fixation of the ProGrip™ laparoscopic self-fixating mesh was found to be significantly better than the fixation of the Tisseel™ system or the SorbaFix™ absorbable fixation system.
format Online
Article
Text
id pubmed-4267587
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-42675872014-12-18 Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs Guérin, Gaëtan Bourges, Xavier Turquier, Frédéric Med Devices (Auckl) Original Research PURPOSE: Tacks and sutures ensure a strong fixation of meshes, but they can be associated with pain and discomfort. Less invasive methods are now available. Three fixation modalities were compared: the ProGrip™ laparoscopic self-fixating mesh; the fibrin glue Tisseel™ with Bard™ Soft Mesh; and the SorbaFix™ absorbable fixation system with Bard™ Soft Mesh. MATERIALS AND METHODS: Meshes (6 cm ×6 cm) were implanted in the preperitoneal space of swine. Samples were explanted 24 hours after surgery. Centered defects were created, and samples (either ten or eleven per fixation type) were loaded in a pressure chamber. For each sample, the pressure, the mesh displacement through the defect, and the measurements of the contact area were recorded. RESULTS: At all pressures tested, the ProGrip™ laparoscopic self-fixating mesh both exhibited a significantly lower displacement through the defect and retained a significantly higher percentage of its initial contact area than either the Bard™ Soft Mesh with Tisseel™ system or the Bard™ Soft Mesh with SorbaFix™ absorbable fixation system. Dislocations occurred with the Bard™ Soft Mesh with Tisseel™ system and with the Bard™ Soft Mesh with SorbaFix™ absorbable fixation system at physiological pressure (,225 mmHg). No dislocation was recorded for the ProGrip™ laparoscopic self-fixating mesh. CONCLUSION: At 24 hours after implantation, the mechanical fixation of the ProGrip™ laparoscopic self-fixating mesh was found to be significantly better than the fixation of the Tisseel™ system or the SorbaFix™ absorbable fixation system. Dove Medical Press 2014-12-09 /pmc/articles/PMC4267587/ /pubmed/25525396 http://dx.doi.org/10.2147/MDER.S71035 Text en © 2014 Guérin et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Guérin, Gaëtan
Bourges, Xavier
Turquier, Frédéric
Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs
title Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs
title_full Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs
title_fullStr Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs
title_full_unstemmed Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs
title_short Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs
title_sort biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4267587/
https://www.ncbi.nlm.nih.gov/pubmed/25525396
http://dx.doi.org/10.2147/MDER.S71035
work_keys_str_mv AT gueringaetan biomechanicalevaluationofthreefixationmodalitiesforpreperitonealinguinalherniarepaira24hourpostoperativestudyinpigs
AT bourgesxavier biomechanicalevaluationofthreefixationmodalitiesforpreperitonealinguinalherniarepaira24hourpostoperativestudyinpigs
AT turquierfrederic biomechanicalevaluationofthreefixationmodalitiesforpreperitonealinguinalherniarepaira24hourpostoperativestudyinpigs