The Role of Pulse Shape in Motor Cortex Transcranial Magnetic Stimulation Using Full-Sine Stimuli
A full-sine (biphasic) pulse waveform is most commonly used for repetitive transcranial magnetic stimulation (TMS), but little is known about how variations in duration or amplitude of distinct pulse segments influence the effectiveness of a single TMS pulse to elicit a corticomotor response. Using...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4267841/ https://www.ncbi.nlm.nih.gov/pubmed/25514673 http://dx.doi.org/10.1371/journal.pone.0115247 |
_version_ | 1782349205490106368 |
---|---|
author | Delvendahl, Igor Gattinger, Norbert Berger, Thomas Gleich, Bernhard Siebner, Hartwig R. Mall, Volker |
author_facet | Delvendahl, Igor Gattinger, Norbert Berger, Thomas Gleich, Bernhard Siebner, Hartwig R. Mall, Volker |
author_sort | Delvendahl, Igor |
collection | PubMed |
description | A full-sine (biphasic) pulse waveform is most commonly used for repetitive transcranial magnetic stimulation (TMS), but little is known about how variations in duration or amplitude of distinct pulse segments influence the effectiveness of a single TMS pulse to elicit a corticomotor response. Using a novel TMS device, we systematically varied the configuration of full-sine pulses to assess the impact of configuration changes on resting motor threshold (RMT) as measure of stimulation effectiveness with single-pulse TMS of the non-dominant motor hand area (M1). In young healthy volunteers, we (i) compared monophasic, half-sine, and full-sine pulses, (ii) applied two-segment pulses consisting of two identical half-sines, and (iii) manipulated amplitude, duration, and current direction of the first or second full-sine pulse half-segments. RMT was significantly higher using half-sine or monophasic pulses compared with full-sine. Pulses combining two half-sines of identical polarity and duration were also characterized by higher RMT than full-sine stimuli resulting. For full-sine stimuli, decreasing the amplitude of the half-segment inducing posterior-anterior oriented current in M1 resulted in considerably higher RMT, whereas varying the amplitude of the half-segment inducing anterior-posterior current had a smaller effect. These findings provide direct experimental evidence that the pulse segment inducing a posterior-anterior directed current in M1 contributes most to corticospinal pathway excitation. Preferential excitation of neuronal target cells in the posterior-anterior segment or targeting of different neuronal structures by the two half-segments can explain this result. Thus, our findings help understanding the mechanisms of neural stimulation by full-sine TMS. |
format | Online Article Text |
id | pubmed-4267841 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-42678412014-12-26 The Role of Pulse Shape in Motor Cortex Transcranial Magnetic Stimulation Using Full-Sine Stimuli Delvendahl, Igor Gattinger, Norbert Berger, Thomas Gleich, Bernhard Siebner, Hartwig R. Mall, Volker PLoS One Research Article A full-sine (biphasic) pulse waveform is most commonly used for repetitive transcranial magnetic stimulation (TMS), but little is known about how variations in duration or amplitude of distinct pulse segments influence the effectiveness of a single TMS pulse to elicit a corticomotor response. Using a novel TMS device, we systematically varied the configuration of full-sine pulses to assess the impact of configuration changes on resting motor threshold (RMT) as measure of stimulation effectiveness with single-pulse TMS of the non-dominant motor hand area (M1). In young healthy volunteers, we (i) compared monophasic, half-sine, and full-sine pulses, (ii) applied two-segment pulses consisting of two identical half-sines, and (iii) manipulated amplitude, duration, and current direction of the first or second full-sine pulse half-segments. RMT was significantly higher using half-sine or monophasic pulses compared with full-sine. Pulses combining two half-sines of identical polarity and duration were also characterized by higher RMT than full-sine stimuli resulting. For full-sine stimuli, decreasing the amplitude of the half-segment inducing posterior-anterior oriented current in M1 resulted in considerably higher RMT, whereas varying the amplitude of the half-segment inducing anterior-posterior current had a smaller effect. These findings provide direct experimental evidence that the pulse segment inducing a posterior-anterior directed current in M1 contributes most to corticospinal pathway excitation. Preferential excitation of neuronal target cells in the posterior-anterior segment or targeting of different neuronal structures by the two half-segments can explain this result. Thus, our findings help understanding the mechanisms of neural stimulation by full-sine TMS. Public Library of Science 2014-12-16 /pmc/articles/PMC4267841/ /pubmed/25514673 http://dx.doi.org/10.1371/journal.pone.0115247 Text en © 2014 Delvendahl http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Delvendahl, Igor Gattinger, Norbert Berger, Thomas Gleich, Bernhard Siebner, Hartwig R. Mall, Volker The Role of Pulse Shape in Motor Cortex Transcranial Magnetic Stimulation Using Full-Sine Stimuli |
title | The Role of Pulse Shape in Motor Cortex Transcranial Magnetic Stimulation Using Full-Sine Stimuli |
title_full | The Role of Pulse Shape in Motor Cortex Transcranial Magnetic Stimulation Using Full-Sine Stimuli |
title_fullStr | The Role of Pulse Shape in Motor Cortex Transcranial Magnetic Stimulation Using Full-Sine Stimuli |
title_full_unstemmed | The Role of Pulse Shape in Motor Cortex Transcranial Magnetic Stimulation Using Full-Sine Stimuli |
title_short | The Role of Pulse Shape in Motor Cortex Transcranial Magnetic Stimulation Using Full-Sine Stimuli |
title_sort | role of pulse shape in motor cortex transcranial magnetic stimulation using full-sine stimuli |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4267841/ https://www.ncbi.nlm.nih.gov/pubmed/25514673 http://dx.doi.org/10.1371/journal.pone.0115247 |
work_keys_str_mv | AT delvendahligor theroleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT gattingernorbert theroleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT bergerthomas theroleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT gleichbernhard theroleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT siebnerhartwigr theroleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT mallvolker theroleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT delvendahligor roleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT gattingernorbert roleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT bergerthomas roleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT gleichbernhard roleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT siebnerhartwigr roleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli AT mallvolker roleofpulseshapeinmotorcortextranscranialmagneticstimulationusingfullsinestimuli |