Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function
BACKGROUND: We sought to determine whether heart rate variability (HRV), blood pressure (BP) variability, and baroreceptor-heart rate reflex sensitivity can be reliably assessed using finger volume pulse waveforms obtained from the commercially available EndoPAT device. METHODS: Non-invasive BP (Fin...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4269858/ https://www.ncbi.nlm.nih.gov/pubmed/25487432 http://dx.doi.org/10.1186/1471-2261-14-180 |
_version_ | 1782349402216595456 |
---|---|
author | Linder, Jonathan R Stauss, Harald M Gindes, Holly Pierce, Gary L Von Bergen, Nicholas H Haynes, William G Fiedorowicz, Jess G |
author_facet | Linder, Jonathan R Stauss, Harald M Gindes, Holly Pierce, Gary L Von Bergen, Nicholas H Haynes, William G Fiedorowicz, Jess G |
author_sort | Linder, Jonathan R |
collection | PubMed |
description | BACKGROUND: We sought to determine whether heart rate variability (HRV), blood pressure (BP) variability, and baroreceptor-heart rate reflex sensitivity can be reliably assessed using finger volume pulse waveforms obtained from the commercially available EndoPAT device. METHODS: Non-invasive BP (Finometer Pro as a non-invasive standard) and finger volume (EndoPAT) waveforms were recorded in 65 adults (37 ± 14 years; 60% female) and systolic BP and heart rate (HR) time series were derived after calibrating the EndoPAT signal based on systolic and diastolic BP values obtained by a sphygomomanometer. Transfer function analyses were performed to test for coherence between systolic BP and HR time series derived from the Finometer and EndoPAT devices. Time-domain HRV parameters, frequency domain HR and systolic BP variability parameters, and baroreflex sensitivity (sequence technique) were computed from Finometer- and EndoPAT-derived time series and intraclass correlation coefficients (ICC) were calculated. RESULTS: Squared coherence between systolic BP time series derived from the Finometer and EndoPAT devices was low, suggesting poor correlation. In contrast, squared coherence between HR time series derived from the two devices was excellent [High Frequency (HF) = 0.80, Low Frequency (LF) = 0.81], with gain values close to 1.0. ICC values for time- and frequency-domain HRV parameters were excellent (>0.9 except for relative HF HRV, which was 0.77), while ICC values for frequency-domain BP variability parameters and baroreceptor-HR reflex sensitivity were low. CONCLUSIONS: Finger volume pulse waveforms can be used to reliably assess both time-domain and frequency-domain HR variability. However, frequency domain BP variability parameters cannot be reliably assessed from finger volume pulse waveforms using the simple calibration technique used in this study. |
format | Online Article Text |
id | pubmed-4269858 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42698582014-12-18 Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function Linder, Jonathan R Stauss, Harald M Gindes, Holly Pierce, Gary L Von Bergen, Nicholas H Haynes, William G Fiedorowicz, Jess G BMC Cardiovasc Disord Research Article BACKGROUND: We sought to determine whether heart rate variability (HRV), blood pressure (BP) variability, and baroreceptor-heart rate reflex sensitivity can be reliably assessed using finger volume pulse waveforms obtained from the commercially available EndoPAT device. METHODS: Non-invasive BP (Finometer Pro as a non-invasive standard) and finger volume (EndoPAT) waveforms were recorded in 65 adults (37 ± 14 years; 60% female) and systolic BP and heart rate (HR) time series were derived after calibrating the EndoPAT signal based on systolic and diastolic BP values obtained by a sphygomomanometer. Transfer function analyses were performed to test for coherence between systolic BP and HR time series derived from the Finometer and EndoPAT devices. Time-domain HRV parameters, frequency domain HR and systolic BP variability parameters, and baroreflex sensitivity (sequence technique) were computed from Finometer- and EndoPAT-derived time series and intraclass correlation coefficients (ICC) were calculated. RESULTS: Squared coherence between systolic BP time series derived from the Finometer and EndoPAT devices was low, suggesting poor correlation. In contrast, squared coherence between HR time series derived from the two devices was excellent [High Frequency (HF) = 0.80, Low Frequency (LF) = 0.81], with gain values close to 1.0. ICC values for time- and frequency-domain HRV parameters were excellent (>0.9 except for relative HF HRV, which was 0.77), while ICC values for frequency-domain BP variability parameters and baroreceptor-HR reflex sensitivity were low. CONCLUSIONS: Finger volume pulse waveforms can be used to reliably assess both time-domain and frequency-domain HR variability. However, frequency domain BP variability parameters cannot be reliably assessed from finger volume pulse waveforms using the simple calibration technique used in this study. BioMed Central 2014-12-09 /pmc/articles/PMC4269858/ /pubmed/25487432 http://dx.doi.org/10.1186/1471-2261-14-180 Text en © Linder et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Linder, Jonathan R Stauss, Harald M Gindes, Holly Pierce, Gary L Von Bergen, Nicholas H Haynes, William G Fiedorowicz, Jess G Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function |
title | Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function |
title_full | Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function |
title_fullStr | Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function |
title_full_unstemmed | Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function |
title_short | Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function |
title_sort | finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4269858/ https://www.ncbi.nlm.nih.gov/pubmed/25487432 http://dx.doi.org/10.1186/1471-2261-14-180 |
work_keys_str_mv | AT linderjonathanr fingervolumepulsewaveformsfacilitatereliableassessmentofheartratevariabilitybutnotbloodpressurevariabilityorbaroreflexfunction AT staussharaldm fingervolumepulsewaveformsfacilitatereliableassessmentofheartratevariabilitybutnotbloodpressurevariabilityorbaroreflexfunction AT gindesholly fingervolumepulsewaveformsfacilitatereliableassessmentofheartratevariabilitybutnotbloodpressurevariabilityorbaroreflexfunction AT piercegaryl fingervolumepulsewaveformsfacilitatereliableassessmentofheartratevariabilitybutnotbloodpressurevariabilityorbaroreflexfunction AT vonbergennicholash fingervolumepulsewaveformsfacilitatereliableassessmentofheartratevariabilitybutnotbloodpressurevariabilityorbaroreflexfunction AT hayneswilliamg fingervolumepulsewaveformsfacilitatereliableassessmentofheartratevariabilitybutnotbloodpressurevariabilityorbaroreflexfunction AT fiedorowiczjessg fingervolumepulsewaveformsfacilitatereliableassessmentofheartratevariabilitybutnotbloodpressurevariabilityorbaroreflexfunction |