Cargando…

Implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study

BACKGROUND: Intermedin (IMD) is involved in the prevention of atherosclerotic plaque progression, possessing cardioprotective effects from hypertrophy, fibrosis and ischemia-reperfusion injury. Elevated plasma IMD levels have been demonstrated in patients with acute coronary syndromes. No human stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamac, Aylin Hatice, Bacaksiz, Ahmet, Ismailoglu, Ziya, Kucukbuzcu, Sitki, Sevgili, Emrah, Asoglu, Emin, Nasifov, Muharrem, Jafarov, Parviz, Erdogan, Ercan, Goktekin, Omer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4271361/
https://www.ncbi.nlm.nih.gov/pubmed/25495100
http://dx.doi.org/10.1186/1471-2261-14-182
_version_ 1782349589086470144
author Yamac, Aylin Hatice
Bacaksiz, Ahmet
Ismailoglu, Ziya
Kucukbuzcu, Sitki
Sevgili, Emrah
Asoglu, Emin
Nasifov, Muharrem
Jafarov, Parviz
Erdogan, Ercan
Goktekin, Omer
author_facet Yamac, Aylin Hatice
Bacaksiz, Ahmet
Ismailoglu, Ziya
Kucukbuzcu, Sitki
Sevgili, Emrah
Asoglu, Emin
Nasifov, Muharrem
Jafarov, Parviz
Erdogan, Ercan
Goktekin, Omer
author_sort Yamac, Aylin Hatice
collection PubMed
description BACKGROUND: Intermedin (IMD) is involved in the prevention of atherosclerotic plaque progression, possessing cardioprotective effects from hypertrophy, fibrosis and ischemia-reperfusion injury. Elevated plasma IMD levels have been demonstrated in patients with acute coronary syndromes. No human study has examined the role of IMD in stable patients who underwent diagnostic coronary angiography with suspicion of coronary artery disease (CAD). Thus we investigated the role of IMD as a biomarker to discriminate patients with CAD and predict those with severe disease who require early and intensive therapeutic intervention before presenting with acute coronary syndrome. METHODS: Eligible two hundred and thirty-eight consecutive patients (123 males, mean age 58.4 ± 10.0 years) who underwent first-time diagnostic coronary angiography were included in this study. Plasma concentrations of IMD were measured from arterial blood samples by the enzyme-linked immunosorbent assay. Patients were divided into three groups according to the presence and degree of CAD, consisting of 48 patients with normal coronary anatomy (Group 1), 111 patients with < 50% coronary stenosis (Group 2), and 79 patients with ≥ 50% stenosis in at least one of the major coronary arteries (group 3). The severity and extent of CAD was evaluated by calculations of the vessel, Gensini, and SYNTAX scores. RESULTS: Circulating plasma IMD levels in patients with CAD were significantly higher than those in patients without CAD (157.7 ± 9.6, 134.8 ± 11.9, and 117.6 ± 7.9 pg/mL in groups 3, 2 and 1 respectively; p < 0.001). Besides, plasma IMD levels were correlated with Gensini and SYNTAX scores (r(s) = 0.742, and r(s) = 0.296, respectively; p < 0.05). The presence of ≥50% coronary artery stenosis could be predicted if a cut-off value of 147.7 pg/mL for plasma IMD was used with 88.6% sensitivity and 88.7% specificity. Moreover, a plasma IMD level of <126.6 pg/mL could discriminate a patient with normal coronary arteries from patients with angiographically proven CAD with a sensitivity and specificity of 84.7%, and 83.3% respectively. CONCLUSIONS: We demonstrated that IMD might be used as a biomarker to predict CAD and its severity in patients who underwent first time diagnostic coronary angiography.
format Online
Article
Text
id pubmed-4271361
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42713612014-12-20 Implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study Yamac, Aylin Hatice Bacaksiz, Ahmet Ismailoglu, Ziya Kucukbuzcu, Sitki Sevgili, Emrah Asoglu, Emin Nasifov, Muharrem Jafarov, Parviz Erdogan, Ercan Goktekin, Omer BMC Cardiovasc Disord Research Article BACKGROUND: Intermedin (IMD) is involved in the prevention of atherosclerotic plaque progression, possessing cardioprotective effects from hypertrophy, fibrosis and ischemia-reperfusion injury. Elevated plasma IMD levels have been demonstrated in patients with acute coronary syndromes. No human study has examined the role of IMD in stable patients who underwent diagnostic coronary angiography with suspicion of coronary artery disease (CAD). Thus we investigated the role of IMD as a biomarker to discriminate patients with CAD and predict those with severe disease who require early and intensive therapeutic intervention before presenting with acute coronary syndrome. METHODS: Eligible two hundred and thirty-eight consecutive patients (123 males, mean age 58.4 ± 10.0 years) who underwent first-time diagnostic coronary angiography were included in this study. Plasma concentrations of IMD were measured from arterial blood samples by the enzyme-linked immunosorbent assay. Patients were divided into three groups according to the presence and degree of CAD, consisting of 48 patients with normal coronary anatomy (Group 1), 111 patients with < 50% coronary stenosis (Group 2), and 79 patients with ≥ 50% stenosis in at least one of the major coronary arteries (group 3). The severity and extent of CAD was evaluated by calculations of the vessel, Gensini, and SYNTAX scores. RESULTS: Circulating plasma IMD levels in patients with CAD were significantly higher than those in patients without CAD (157.7 ± 9.6, 134.8 ± 11.9, and 117.6 ± 7.9 pg/mL in groups 3, 2 and 1 respectively; p < 0.001). Besides, plasma IMD levels were correlated with Gensini and SYNTAX scores (r(s) = 0.742, and r(s) = 0.296, respectively; p < 0.05). The presence of ≥50% coronary artery stenosis could be predicted if a cut-off value of 147.7 pg/mL for plasma IMD was used with 88.6% sensitivity and 88.7% specificity. Moreover, a plasma IMD level of <126.6 pg/mL could discriminate a patient with normal coronary arteries from patients with angiographically proven CAD with a sensitivity and specificity of 84.7%, and 83.3% respectively. CONCLUSIONS: We demonstrated that IMD might be used as a biomarker to predict CAD and its severity in patients who underwent first time diagnostic coronary angiography. BioMed Central 2014-12-11 /pmc/articles/PMC4271361/ /pubmed/25495100 http://dx.doi.org/10.1186/1471-2261-14-182 Text en © Yamac et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Yamac, Aylin Hatice
Bacaksiz, Ahmet
Ismailoglu, Ziya
Kucukbuzcu, Sitki
Sevgili, Emrah
Asoglu, Emin
Nasifov, Muharrem
Jafarov, Parviz
Erdogan, Ercan
Goktekin, Omer
Implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study
title Implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study
title_full Implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study
title_fullStr Implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study
title_full_unstemmed Implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study
title_short Implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study
title_sort implication of plasma intermedin levels in patients who underwent first-time diagnostic coronary angiography: a single centre, cross-sectional study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4271361/
https://www.ncbi.nlm.nih.gov/pubmed/25495100
http://dx.doi.org/10.1186/1471-2261-14-182
work_keys_str_mv AT yamacaylinhatice implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT bacaksizahmet implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT ismailogluziya implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT kucukbuzcusitki implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT sevgiliemrah implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT asogluemin implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT nasifovmuharrem implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT jafarovparviz implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT erdoganercan implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy
AT goktekinomer implicationofplasmaintermedinlevelsinpatientswhounderwentfirsttimediagnosticcoronaryangiographyasinglecentrecrosssectionalstudy