Cargando…
Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
BACKGROUND: Quantification of the longitudinal- and transverse relaxation time in the myocardium has shown to provide important information in cardiac diagnostics. Methods for cardiac relaxation time mapping generally demand a long breath hold to measure either T1 or T2 in a single 2D slice. In this...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4272556/ https://www.ncbi.nlm.nih.gov/pubmed/25526880 http://dx.doi.org/10.1186/s12968-014-0102-0 |
_version_ | 1782349735735066624 |
---|---|
author | Kvernby, Sofia Warntjes, Marcel Jan Bertus Haraldsson, Henrik Carlhäll, Carl-Johan Engvall, Jan Ebbers, Tino |
author_facet | Kvernby, Sofia Warntjes, Marcel Jan Bertus Haraldsson, Henrik Carlhäll, Carl-Johan Engvall, Jan Ebbers, Tino |
author_sort | Kvernby, Sofia |
collection | PubMed |
description | BACKGROUND: Quantification of the longitudinal- and transverse relaxation time in the myocardium has shown to provide important information in cardiac diagnostics. Methods for cardiac relaxation time mapping generally demand a long breath hold to measure either T1 or T2 in a single 2D slice. In this paper we present and evaluate a novel method for 3D interleaved T1 and T2 mapping of the whole left ventricular myocardium within a single breath hold of 15 heartbeats. METHODS: The 3D-QALAS (3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse) is based on a 3D spoiled Turbo Field Echo sequence using inversion recovery with interleaved T2 preparation. Quantification of both T1 and T2 in a volume of 13 slices with a resolution of 2.0x2.0x6.0 mm is obtained from five measurements by using simulations of the longitudinal magnetizations Mz. This acquisition scheme is repeated three times to sample k-space. The method was evaluated both in-vitro (validated against Inversion Recovery and Multi Echo) and in-vivo (validated against MOLLI and Dual Echo). RESULTS: In-vitro, a strong relation was found between 3D-QALAS and Inversion Recovery (R = 0.998; N = 10; p < 0.01) and between 3D-QALAS and Multi Echo (R = 0.996; N = 10; p < 0.01). The 3D-QALAS method showed no dependence on e.g. heart rate in the interval of 40–120 bpm. In healthy myocardium, the mean T1 value was 1083 ± 43 ms (mean ± SD) for 3D-QALAS and 1089 ± 54 ms for MOLLI, while the mean T2 value was 50.4 ± 3.6 ms 3D-QALAS and 50.3 ± 3.5 ms for Dual Echo. No significant difference in in-vivo relaxation times was found between 3D-QALAS and MOLLI (N = 10; p = 0.65) respectively 3D-QALAS and Dual Echo (N = 10; p = 0.925) for the ten healthy volunteers. CONCLUSIONS: The 3D-QALAS method has demonstrated good accuracy and intra-scan variability both in-vitro and in-vivo. It allows rapid acquisition and provides quantitative information of both T1 and T2 relaxation times in the same scan with full coverage of the left ventricle, enabling clinical application in a broader spectrum of cardiac disorders. |
format | Online Article Text |
id | pubmed-4272556 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42725562015-01-02 Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS Kvernby, Sofia Warntjes, Marcel Jan Bertus Haraldsson, Henrik Carlhäll, Carl-Johan Engvall, Jan Ebbers, Tino J Cardiovasc Magn Reson Research BACKGROUND: Quantification of the longitudinal- and transverse relaxation time in the myocardium has shown to provide important information in cardiac diagnostics. Methods for cardiac relaxation time mapping generally demand a long breath hold to measure either T1 or T2 in a single 2D slice. In this paper we present and evaluate a novel method for 3D interleaved T1 and T2 mapping of the whole left ventricular myocardium within a single breath hold of 15 heartbeats. METHODS: The 3D-QALAS (3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse) is based on a 3D spoiled Turbo Field Echo sequence using inversion recovery with interleaved T2 preparation. Quantification of both T1 and T2 in a volume of 13 slices with a resolution of 2.0x2.0x6.0 mm is obtained from five measurements by using simulations of the longitudinal magnetizations Mz. This acquisition scheme is repeated three times to sample k-space. The method was evaluated both in-vitro (validated against Inversion Recovery and Multi Echo) and in-vivo (validated against MOLLI and Dual Echo). RESULTS: In-vitro, a strong relation was found between 3D-QALAS and Inversion Recovery (R = 0.998; N = 10; p < 0.01) and between 3D-QALAS and Multi Echo (R = 0.996; N = 10; p < 0.01). The 3D-QALAS method showed no dependence on e.g. heart rate in the interval of 40–120 bpm. In healthy myocardium, the mean T1 value was 1083 ± 43 ms (mean ± SD) for 3D-QALAS and 1089 ± 54 ms for MOLLI, while the mean T2 value was 50.4 ± 3.6 ms 3D-QALAS and 50.3 ± 3.5 ms for Dual Echo. No significant difference in in-vivo relaxation times was found between 3D-QALAS and MOLLI (N = 10; p = 0.65) respectively 3D-QALAS and Dual Echo (N = 10; p = 0.925) for the ten healthy volunteers. CONCLUSIONS: The 3D-QALAS method has demonstrated good accuracy and intra-scan variability both in-vitro and in-vivo. It allows rapid acquisition and provides quantitative information of both T1 and T2 relaxation times in the same scan with full coverage of the left ventricle, enabling clinical application in a broader spectrum of cardiac disorders. BioMed Central 2014-12-20 /pmc/articles/PMC4272556/ /pubmed/25526880 http://dx.doi.org/10.1186/s12968-014-0102-0 Text en © Kvernby et al.; licensee BioMed Central Ltd. 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Kvernby, Sofia Warntjes, Marcel Jan Bertus Haraldsson, Henrik Carlhäll, Carl-Johan Engvall, Jan Ebbers, Tino Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS |
title | Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS |
title_full | Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS |
title_fullStr | Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS |
title_full_unstemmed | Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS |
title_short | Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS |
title_sort | simultaneous three-dimensional myocardial t1 and t2 mapping in one breath hold with 3d-qalas |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4272556/ https://www.ncbi.nlm.nih.gov/pubmed/25526880 http://dx.doi.org/10.1186/s12968-014-0102-0 |
work_keys_str_mv | AT kvernbysofia simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas AT warntjesmarceljanbertus simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas AT haraldssonhenrik simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas AT carlhallcarljohan simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas AT engvalljan simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas AT ebberstino simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas |