Cargando…

Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS

BACKGROUND: Quantification of the longitudinal- and transverse relaxation time in the myocardium has shown to provide important information in cardiac diagnostics. Methods for cardiac relaxation time mapping generally demand a long breath hold to measure either T1 or T2 in a single 2D slice. In this...

Descripción completa

Detalles Bibliográficos
Autores principales: Kvernby, Sofia, Warntjes, Marcel Jan Bertus, Haraldsson, Henrik, Carlhäll, Carl-Johan, Engvall, Jan, Ebbers, Tino
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4272556/
https://www.ncbi.nlm.nih.gov/pubmed/25526880
http://dx.doi.org/10.1186/s12968-014-0102-0
_version_ 1782349735735066624
author Kvernby, Sofia
Warntjes, Marcel Jan Bertus
Haraldsson, Henrik
Carlhäll, Carl-Johan
Engvall, Jan
Ebbers, Tino
author_facet Kvernby, Sofia
Warntjes, Marcel Jan Bertus
Haraldsson, Henrik
Carlhäll, Carl-Johan
Engvall, Jan
Ebbers, Tino
author_sort Kvernby, Sofia
collection PubMed
description BACKGROUND: Quantification of the longitudinal- and transverse relaxation time in the myocardium has shown to provide important information in cardiac diagnostics. Methods for cardiac relaxation time mapping generally demand a long breath hold to measure either T1 or T2 in a single 2D slice. In this paper we present and evaluate a novel method for 3D interleaved T1 and T2 mapping of the whole left ventricular myocardium within a single breath hold of 15 heartbeats. METHODS: The 3D-QALAS (3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse) is based on a 3D spoiled Turbo Field Echo sequence using inversion recovery with interleaved T2 preparation. Quantification of both T1 and T2 in a volume of 13 slices with a resolution of 2.0x2.0x6.0 mm is obtained from five measurements by using simulations of the longitudinal magnetizations Mz. This acquisition scheme is repeated three times to sample k-space. The method was evaluated both in-vitro (validated against Inversion Recovery and Multi Echo) and in-vivo (validated against MOLLI and Dual Echo). RESULTS: In-vitro, a strong relation was found between 3D-QALAS and Inversion Recovery (R = 0.998; N = 10; p < 0.01) and between 3D-QALAS and Multi Echo (R = 0.996; N = 10; p < 0.01). The 3D-QALAS method showed no dependence on e.g. heart rate in the interval of 40–120 bpm. In healthy myocardium, the mean T1 value was 1083 ± 43 ms (mean ± SD) for 3D-QALAS and 1089 ± 54 ms for MOLLI, while the mean T2 value was 50.4 ± 3.6 ms 3D-QALAS and 50.3 ± 3.5 ms for Dual Echo. No significant difference in in-vivo relaxation times was found between 3D-QALAS and MOLLI (N = 10; p = 0.65) respectively 3D-QALAS and Dual Echo (N = 10; p = 0.925) for the ten healthy volunteers. CONCLUSIONS: The 3D-QALAS method has demonstrated good accuracy and intra-scan variability both in-vitro and in-vivo. It allows rapid acquisition and provides quantitative information of both T1 and T2 relaxation times in the same scan with full coverage of the left ventricle, enabling clinical application in a broader spectrum of cardiac disorders.
format Online
Article
Text
id pubmed-4272556
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42725562015-01-02 Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS Kvernby, Sofia Warntjes, Marcel Jan Bertus Haraldsson, Henrik Carlhäll, Carl-Johan Engvall, Jan Ebbers, Tino J Cardiovasc Magn Reson Research BACKGROUND: Quantification of the longitudinal- and transverse relaxation time in the myocardium has shown to provide important information in cardiac diagnostics. Methods for cardiac relaxation time mapping generally demand a long breath hold to measure either T1 or T2 in a single 2D slice. In this paper we present and evaluate a novel method for 3D interleaved T1 and T2 mapping of the whole left ventricular myocardium within a single breath hold of 15 heartbeats. METHODS: The 3D-QALAS (3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse) is based on a 3D spoiled Turbo Field Echo sequence using inversion recovery with interleaved T2 preparation. Quantification of both T1 and T2 in a volume of 13 slices with a resolution of 2.0x2.0x6.0 mm is obtained from five measurements by using simulations of the longitudinal magnetizations Mz. This acquisition scheme is repeated three times to sample k-space. The method was evaluated both in-vitro (validated against Inversion Recovery and Multi Echo) and in-vivo (validated against MOLLI and Dual Echo). RESULTS: In-vitro, a strong relation was found between 3D-QALAS and Inversion Recovery (R = 0.998; N = 10; p < 0.01) and between 3D-QALAS and Multi Echo (R = 0.996; N = 10; p < 0.01). The 3D-QALAS method showed no dependence on e.g. heart rate in the interval of 40–120 bpm. In healthy myocardium, the mean T1 value was 1083 ± 43 ms (mean ± SD) for 3D-QALAS and 1089 ± 54 ms for MOLLI, while the mean T2 value was 50.4 ± 3.6 ms 3D-QALAS and 50.3 ± 3.5 ms for Dual Echo. No significant difference in in-vivo relaxation times was found between 3D-QALAS and MOLLI (N = 10; p = 0.65) respectively 3D-QALAS and Dual Echo (N = 10; p = 0.925) for the ten healthy volunteers. CONCLUSIONS: The 3D-QALAS method has demonstrated good accuracy and intra-scan variability both in-vitro and in-vivo. It allows rapid acquisition and provides quantitative information of both T1 and T2 relaxation times in the same scan with full coverage of the left ventricle, enabling clinical application in a broader spectrum of cardiac disorders. BioMed Central 2014-12-20 /pmc/articles/PMC4272556/ /pubmed/25526880 http://dx.doi.org/10.1186/s12968-014-0102-0 Text en © Kvernby et al.; licensee BioMed Central Ltd. 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Kvernby, Sofia
Warntjes, Marcel Jan Bertus
Haraldsson, Henrik
Carlhäll, Carl-Johan
Engvall, Jan
Ebbers, Tino
Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
title Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
title_full Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
title_fullStr Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
title_full_unstemmed Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
title_short Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
title_sort simultaneous three-dimensional myocardial t1 and t2 mapping in one breath hold with 3d-qalas
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4272556/
https://www.ncbi.nlm.nih.gov/pubmed/25526880
http://dx.doi.org/10.1186/s12968-014-0102-0
work_keys_str_mv AT kvernbysofia simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas
AT warntjesmarceljanbertus simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas
AT haraldssonhenrik simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas
AT carlhallcarljohan simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas
AT engvalljan simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas
AT ebberstino simultaneousthreedimensionalmyocardialt1andt2mappinginonebreathholdwith3dqalas