Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems
BACKGROUND: Acinetobacter species are the leading cause of bloodstream infection (BSI), but their correct identification is challenging. We evaluated the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based VITEK MS (bioMérieux, France), and two automated...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4272967/ https://www.ncbi.nlm.nih.gov/pubmed/25553282 http://dx.doi.org/10.3343/alm.2015.35.1.62 |
_version_ | 1782349771427545088 |
---|---|
author | Lee, Seung Yeob Shin, Jong Hee Kim, Soo Hyun Shin, Myung Geun Suh, Soon Pal Ryang, Dong Wook |
author_facet | Lee, Seung Yeob Shin, Jong Hee Kim, Soo Hyun Shin, Myung Geun Suh, Soon Pal Ryang, Dong Wook |
author_sort | Lee, Seung Yeob |
collection | PubMed |
description | BACKGROUND: Acinetobacter species are the leading cause of bloodstream infection (BSI), but their correct identification is challenging. We evaluated the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based VITEK MS (bioMérieux, France), and two automated systems, VITEK 2 (bioMérieux) and MicroScan (Siemens, USA) for identification of Acinetobacter BSI isolates. METHODS: A total of 187 BSI isolates recovered at a university hospital in Korea between 2010 and 2012 were analyzed. The identification results obtained using VITEK MS and two automated systems were compared with those of rpoB sequencing. RESULTS: Of 187 isolates analyzed, 176 were identified to the species level by rpoB sequencing: the Acinetobacter baumannii group (ABG; 101 A. baumannii, 43 A. nosocomialis, 10 A. pittii isolates) was most commonly identified (82.4%), followed by Acinetobacter genomic species 13BJ/14TU (5.3%), A. ursingii (2.1%), A. soli (2.1%), A. bereziniae (1.1%), and A. junii (1.1%). Correct identification rates to the species group (ABG) level or the species level was comparable among the three systems (VITEK MS, 90.3%; VITEK 2, 89.2%; MicroScan, 86.9%). However, VITEK MS generated fewer misidentifications (0.6%) than VITEK 2 (10.8%) and MicroScan (13.1%) (P<0.001). In addition, VITEK MS demonstrated higher specificity (100%) for discrimination between ABG and non-ABG isolates than the other systems (both, 31.8%) (P<0.001). CONCLUSIONS: The VITEK MS system is superior to the VITEK 2 and MicroScan systems for identification of Acinetobacter BSI isolates, with fewer misidentifications and better discrimination between the ABG and non-ABG isolates. |
format | Online Article Text |
id | pubmed-4272967 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-42729672015-01-01 Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems Lee, Seung Yeob Shin, Jong Hee Kim, Soo Hyun Shin, Myung Geun Suh, Soon Pal Ryang, Dong Wook Ann Lab Med Original Article BACKGROUND: Acinetobacter species are the leading cause of bloodstream infection (BSI), but their correct identification is challenging. We evaluated the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based VITEK MS (bioMérieux, France), and two automated systems, VITEK 2 (bioMérieux) and MicroScan (Siemens, USA) for identification of Acinetobacter BSI isolates. METHODS: A total of 187 BSI isolates recovered at a university hospital in Korea between 2010 and 2012 were analyzed. The identification results obtained using VITEK MS and two automated systems were compared with those of rpoB sequencing. RESULTS: Of 187 isolates analyzed, 176 were identified to the species level by rpoB sequencing: the Acinetobacter baumannii group (ABG; 101 A. baumannii, 43 A. nosocomialis, 10 A. pittii isolates) was most commonly identified (82.4%), followed by Acinetobacter genomic species 13BJ/14TU (5.3%), A. ursingii (2.1%), A. soli (2.1%), A. bereziniae (1.1%), and A. junii (1.1%). Correct identification rates to the species group (ABG) level or the species level was comparable among the three systems (VITEK MS, 90.3%; VITEK 2, 89.2%; MicroScan, 86.9%). However, VITEK MS generated fewer misidentifications (0.6%) than VITEK 2 (10.8%) and MicroScan (13.1%) (P<0.001). In addition, VITEK MS demonstrated higher specificity (100%) for discrimination between ABG and non-ABG isolates than the other systems (both, 31.8%) (P<0.001). CONCLUSIONS: The VITEK MS system is superior to the VITEK 2 and MicroScan systems for identification of Acinetobacter BSI isolates, with fewer misidentifications and better discrimination between the ABG and non-ABG isolates. The Korean Society for Laboratory Medicine 2015-01 2014-12-08 /pmc/articles/PMC4272967/ /pubmed/25553282 http://dx.doi.org/10.3343/alm.2015.35.1.62 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Seung Yeob Shin, Jong Hee Kim, Soo Hyun Shin, Myung Geun Suh, Soon Pal Ryang, Dong Wook Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems |
title | Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems |
title_full | Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems |
title_fullStr | Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems |
title_full_unstemmed | Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems |
title_short | Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based VITEK MS System for the Identification of Acinetobacter Species from Blood Cultures: Comparison with VITEK 2 and MicroScan Systems |
title_sort | evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry-based vitek ms system for the identification of acinetobacter species from blood cultures: comparison with vitek 2 and microscan systems |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4272967/ https://www.ncbi.nlm.nih.gov/pubmed/25553282 http://dx.doi.org/10.3343/alm.2015.35.1.62 |
work_keys_str_mv | AT leeseungyeob evaluationofmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrybasedvitekmssystemfortheidentificationofacinetobacterspeciesfrombloodculturescomparisonwithvitek2andmicroscansystems AT shinjonghee evaluationofmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrybasedvitekmssystemfortheidentificationofacinetobacterspeciesfrombloodculturescomparisonwithvitek2andmicroscansystems AT kimsoohyun evaluationofmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrybasedvitekmssystemfortheidentificationofacinetobacterspeciesfrombloodculturescomparisonwithvitek2andmicroscansystems AT shinmyunggeun evaluationofmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrybasedvitekmssystemfortheidentificationofacinetobacterspeciesfrombloodculturescomparisonwithvitek2andmicroscansystems AT suhsoonpal evaluationofmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrybasedvitekmssystemfortheidentificationofacinetobacterspeciesfrombloodculturescomparisonwithvitek2andmicroscansystems AT ryangdongwook evaluationofmatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrybasedvitekmssystemfortheidentificationofacinetobacterspeciesfrombloodculturescomparisonwithvitek2andmicroscansystems |