Cargando…
Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series
BACKGROUND: Posterior capsule opacification (PCO) is the most common post-operative complication associated with cataract surgery and is mostly treated with Nd:YAG laser capsulotomy. Here, we demonstrate the use of high-resolution spectral-domain optical coherence tomography (OCT) as a technique for...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4273457/ https://www.ncbi.nlm.nih.gov/pubmed/25403826 http://dx.doi.org/10.1186/1471-2415-14-131 |
_version_ | 1782349838125367296 |
---|---|
author | Hawlina, Gregor Perovšek, Darko Drnovšek-Olup, Brigita Možina, Janez Gregorčič, Peter |
author_facet | Hawlina, Gregor Perovšek, Darko Drnovšek-Olup, Brigita Možina, Janez Gregorčič, Peter |
author_sort | Hawlina, Gregor |
collection | PubMed |
description | BACKGROUND: Posterior capsule opacification (PCO) is the most common post-operative complication associated with cataract surgery and is mostly treated with Nd:YAG laser capsulotomy. Here, we demonstrate the use of high-resolution spectral-domain optical coherence tomography (OCT) as a technique for PCO analysis. Additionally, we evaluate the influence of PCO types and the distance between the intraocular lens (IOL) and the posterior capsule (PC), i.e., the IOL/PC distance, on the total-pulse energy required for the Nd:YAG laser posterior capsulotomy. METHODS: 47 eyes with PCO scheduled for the Nd:YAG procedure were examined and divided into four categories: fibrosis, pearl, mixed type and late-postoperative capsular bag distension syndrome. Using custom-made computer software for OCT image analysis, the IOL/PC distances in two dimensions were measured. The IOL/PC distances were compared with those of a control group of 15 eyes without PCO. The influence of the different PCO types and the IOL/PC distance on the total-pulse energy required for the Nd:YAG procedure was analyzed. RESULTS: The total-pulse energy required for a laser capsulotomy differs significantly between PCO types (p = 0.005, Kruskal-Wallis test). The highest energy was required for the fibrosis PCO type, followed by mixed, pearl and late-postoperative capsular bag distension syndrome. The IOL/PC distance also significantly influenced the total-pulse energy required for laser capsulotomy (p = 0.028, linear regression). Lower total-pulse energy was expected for a larger IOL/PC distance. CONCLUSIONS: Our study indicates that the PCO types and the IOL/PC distance influence the total-pulse energy required for Nd:YAG capsulotomy. The presented OCT method has the potential to become an additional tool for PCO characterization. Our results are important for a better understanding of the photodisruptive mechanisms in Nd:YAG capsulotomy. |
format | Online Article Text |
id | pubmed-4273457 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42734572014-12-23 Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series Hawlina, Gregor Perovšek, Darko Drnovšek-Olup, Brigita Možina, Janez Gregorčič, Peter BMC Ophthalmol Research Article BACKGROUND: Posterior capsule opacification (PCO) is the most common post-operative complication associated with cataract surgery and is mostly treated with Nd:YAG laser capsulotomy. Here, we demonstrate the use of high-resolution spectral-domain optical coherence tomography (OCT) as a technique for PCO analysis. Additionally, we evaluate the influence of PCO types and the distance between the intraocular lens (IOL) and the posterior capsule (PC), i.e., the IOL/PC distance, on the total-pulse energy required for the Nd:YAG laser posterior capsulotomy. METHODS: 47 eyes with PCO scheduled for the Nd:YAG procedure were examined and divided into four categories: fibrosis, pearl, mixed type and late-postoperative capsular bag distension syndrome. Using custom-made computer software for OCT image analysis, the IOL/PC distances in two dimensions were measured. The IOL/PC distances were compared with those of a control group of 15 eyes without PCO. The influence of the different PCO types and the IOL/PC distance on the total-pulse energy required for the Nd:YAG procedure was analyzed. RESULTS: The total-pulse energy required for a laser capsulotomy differs significantly between PCO types (p = 0.005, Kruskal-Wallis test). The highest energy was required for the fibrosis PCO type, followed by mixed, pearl and late-postoperative capsular bag distension syndrome. The IOL/PC distance also significantly influenced the total-pulse energy required for laser capsulotomy (p = 0.028, linear regression). Lower total-pulse energy was expected for a larger IOL/PC distance. CONCLUSIONS: Our study indicates that the PCO types and the IOL/PC distance influence the total-pulse energy required for Nd:YAG capsulotomy. The presented OCT method has the potential to become an additional tool for PCO characterization. Our results are important for a better understanding of the photodisruptive mechanisms in Nd:YAG capsulotomy. BioMed Central 2014-11-18 /pmc/articles/PMC4273457/ /pubmed/25403826 http://dx.doi.org/10.1186/1471-2415-14-131 Text en © Hawlina et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Hawlina, Gregor Perovšek, Darko Drnovšek-Olup, Brigita Možina, Janez Gregorčič, Peter Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series |
title | Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series |
title_full | Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series |
title_fullStr | Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series |
title_full_unstemmed | Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series |
title_short | Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series |
title_sort | optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for nd:yag capsulotomy: a case series |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4273457/ https://www.ncbi.nlm.nih.gov/pubmed/25403826 http://dx.doi.org/10.1186/1471-2415-14-131 |
work_keys_str_mv | AT hawlinagregor opticalcoherencetomographyforaninvivostudyofposteriorcapsuleopacificationtypesandtheirinfluenceonthetotalpulseenergyrequiredforndyagcapsulotomyacaseseries AT perovsekdarko opticalcoherencetomographyforaninvivostudyofposteriorcapsuleopacificationtypesandtheirinfluenceonthetotalpulseenergyrequiredforndyagcapsulotomyacaseseries AT drnovsekolupbrigita opticalcoherencetomographyforaninvivostudyofposteriorcapsuleopacificationtypesandtheirinfluenceonthetotalpulseenergyrequiredforndyagcapsulotomyacaseseries AT mozinajanez opticalcoherencetomographyforaninvivostudyofposteriorcapsuleopacificationtypesandtheirinfluenceonthetotalpulseenergyrequiredforndyagcapsulotomyacaseseries AT gregorcicpeter opticalcoherencetomographyforaninvivostudyofposteriorcapsuleopacificationtypesandtheirinfluenceonthetotalpulseenergyrequiredforndyagcapsulotomyacaseseries |