Cargando…
Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?
Objective(s). The major challenge encountered to decrease the milliamperes (mA) level in X-ray imaging systems is the quantum noise phenomena. This investigation evaluated dose exposure and image resolution of a low dose X-ray imaging (LDXI) prototype comprising a low mA X-ray source and a novel mic...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4276328/ https://www.ncbi.nlm.nih.gov/pubmed/25574389 http://dx.doi.org/10.1155/2014/543524 |
_version_ | 1782350240648527872 |
---|---|
author | Mistry, Arnav R. Uzbelger Feldman, Daniel Yang, Jie Ryterski, Eric |
author_facet | Mistry, Arnav R. Uzbelger Feldman, Daniel Yang, Jie Ryterski, Eric |
author_sort | Mistry, Arnav R. |
collection | PubMed |
description | Objective(s). The major challenge encountered to decrease the milliamperes (mA) level in X-ray imaging systems is the quantum noise phenomena. This investigation evaluated dose exposure and image resolution of a low dose X-ray imaging (LDXI) prototype comprising a low mA X-ray source and a novel microlens-based sensor relative to current imaging technologies. Study Design. A LDXI in static (group 1) and dynamic (group 2) modes was compared to medical fluoroscopy (group 3), digital intraoral radiography (group 4), and CBCT scan (group 5) using a dental phantom. Results. The Mann-Whitney test showed no statistical significance (α = 0.01) in dose exposure between groups 1 and 3 and 1 and 4 and timing exposure (seconds) between groups 1 and 5 and 2 and 3. Image resolution test showed group 1 > group 4 > group 2 > group 3 > group 5. Conclusions. The LDXI proved the concept for obtaining a high definition image resolution for static and dynamic radiography at lower or similar dose exposure and smaller pixel size, respectively, when compared to current imaging technologies. Lower mA at the X-ray source and high QE at the detector level principles with microlens could be applied to current imaging technologies to considerably reduce dose exposure without compromising image resolution in the near future. |
format | Online Article Text |
id | pubmed-4276328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-42763282015-01-08 Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging? Mistry, Arnav R. Uzbelger Feldman, Daniel Yang, Jie Ryterski, Eric Radiol Res Pract Research Article Objective(s). The major challenge encountered to decrease the milliamperes (mA) level in X-ray imaging systems is the quantum noise phenomena. This investigation evaluated dose exposure and image resolution of a low dose X-ray imaging (LDXI) prototype comprising a low mA X-ray source and a novel microlens-based sensor relative to current imaging technologies. Study Design. A LDXI in static (group 1) and dynamic (group 2) modes was compared to medical fluoroscopy (group 3), digital intraoral radiography (group 4), and CBCT scan (group 5) using a dental phantom. Results. The Mann-Whitney test showed no statistical significance (α = 0.01) in dose exposure between groups 1 and 3 and 1 and 4 and timing exposure (seconds) between groups 1 and 5 and 2 and 3. Image resolution test showed group 1 > group 4 > group 2 > group 3 > group 5. Conclusions. The LDXI proved the concept for obtaining a high definition image resolution for static and dynamic radiography at lower or similar dose exposure and smaller pixel size, respectively, when compared to current imaging technologies. Lower mA at the X-ray source and high QE at the detector level principles with microlens could be applied to current imaging technologies to considerably reduce dose exposure without compromising image resolution in the near future. Hindawi Publishing Corporation 2014 2014-12-10 /pmc/articles/PMC4276328/ /pubmed/25574389 http://dx.doi.org/10.1155/2014/543524 Text en Copyright © 2014 Arnav R. Mistry et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Mistry, Arnav R. Uzbelger Feldman, Daniel Yang, Jie Ryterski, Eric Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging? |
title | Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging? |
title_full | Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging? |
title_fullStr | Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging? |
title_full_unstemmed | Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging? |
title_short | Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging? |
title_sort | low dose x-ray sources and high quantum efficiency sensors: the next challenge in dental digital imaging? |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4276328/ https://www.ncbi.nlm.nih.gov/pubmed/25574389 http://dx.doi.org/10.1155/2014/543524 |
work_keys_str_mv | AT mistryarnavr lowdosexraysourcesandhighquantumefficiencysensorsthenextchallengeindentaldigitalimaging AT uzbelgerfeldmandaniel lowdosexraysourcesandhighquantumefficiencysensorsthenextchallengeindentaldigitalimaging AT yangjie lowdosexraysourcesandhighquantumefficiencysensorsthenextchallengeindentaldigitalimaging AT ryterskieric lowdosexraysourcesandhighquantumefficiencysensorsthenextchallengeindentaldigitalimaging |