Cargando…

Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?

Objective(s). The major challenge encountered to decrease the milliamperes (mA) level in X-ray imaging systems is the quantum noise phenomena. This investigation evaluated dose exposure and image resolution of a low dose X-ray imaging (LDXI) prototype comprising a low mA X-ray source and a novel mic...

Descripción completa

Detalles Bibliográficos
Autores principales: Mistry, Arnav R., Uzbelger Feldman, Daniel, Yang, Jie, Ryterski, Eric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4276328/
https://www.ncbi.nlm.nih.gov/pubmed/25574389
http://dx.doi.org/10.1155/2014/543524
_version_ 1782350240648527872
author Mistry, Arnav R.
Uzbelger Feldman, Daniel
Yang, Jie
Ryterski, Eric
author_facet Mistry, Arnav R.
Uzbelger Feldman, Daniel
Yang, Jie
Ryterski, Eric
author_sort Mistry, Arnav R.
collection PubMed
description Objective(s). The major challenge encountered to decrease the milliamperes (mA) level in X-ray imaging systems is the quantum noise phenomena. This investigation evaluated dose exposure and image resolution of a low dose X-ray imaging (LDXI) prototype comprising a low mA X-ray source and a novel microlens-based sensor relative to current imaging technologies. Study Design. A LDXI in static (group 1) and dynamic (group 2) modes was compared to medical fluoroscopy (group 3), digital intraoral radiography (group 4), and CBCT scan (group 5) using a dental phantom. Results. The Mann-Whitney test showed no statistical significance (α = 0.01) in dose exposure between groups 1 and 3 and 1 and 4 and timing exposure (seconds) between groups 1 and 5 and 2 and 3. Image resolution test showed group 1 > group 4 > group 2 > group 3 > group 5. Conclusions. The LDXI proved the concept for obtaining a high definition image resolution for static and dynamic radiography at lower or similar dose exposure and smaller pixel size, respectively, when compared to current imaging technologies. Lower mA at the X-ray source and high QE at the detector level principles with microlens could be applied to current imaging technologies to considerably reduce dose exposure without compromising image resolution in the near future.
format Online
Article
Text
id pubmed-4276328
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-42763282015-01-08 Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging? Mistry, Arnav R. Uzbelger Feldman, Daniel Yang, Jie Ryterski, Eric Radiol Res Pract Research Article Objective(s). The major challenge encountered to decrease the milliamperes (mA) level in X-ray imaging systems is the quantum noise phenomena. This investigation evaluated dose exposure and image resolution of a low dose X-ray imaging (LDXI) prototype comprising a low mA X-ray source and a novel microlens-based sensor relative to current imaging technologies. Study Design. A LDXI in static (group 1) and dynamic (group 2) modes was compared to medical fluoroscopy (group 3), digital intraoral radiography (group 4), and CBCT scan (group 5) using a dental phantom. Results. The Mann-Whitney test showed no statistical significance (α = 0.01) in dose exposure between groups 1 and 3 and 1 and 4 and timing exposure (seconds) between groups 1 and 5 and 2 and 3. Image resolution test showed group 1 > group 4 > group 2 > group 3 > group 5. Conclusions. The LDXI proved the concept for obtaining a high definition image resolution for static and dynamic radiography at lower or similar dose exposure and smaller pixel size, respectively, when compared to current imaging technologies. Lower mA at the X-ray source and high QE at the detector level principles with microlens could be applied to current imaging technologies to considerably reduce dose exposure without compromising image resolution in the near future. Hindawi Publishing Corporation 2014 2014-12-10 /pmc/articles/PMC4276328/ /pubmed/25574389 http://dx.doi.org/10.1155/2014/543524 Text en Copyright © 2014 Arnav R. Mistry et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Mistry, Arnav R.
Uzbelger Feldman, Daniel
Yang, Jie
Ryterski, Eric
Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?
title Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?
title_full Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?
title_fullStr Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?
title_full_unstemmed Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?
title_short Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?
title_sort low dose x-ray sources and high quantum efficiency sensors: the next challenge in dental digital imaging?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4276328/
https://www.ncbi.nlm.nih.gov/pubmed/25574389
http://dx.doi.org/10.1155/2014/543524
work_keys_str_mv AT mistryarnavr lowdosexraysourcesandhighquantumefficiencysensorsthenextchallengeindentaldigitalimaging
AT uzbelgerfeldmandaniel lowdosexraysourcesandhighquantumefficiencysensorsthenextchallengeindentaldigitalimaging
AT yangjie lowdosexraysourcesandhighquantumefficiencysensorsthenextchallengeindentaldigitalimaging
AT ryterskieric lowdosexraysourcesandhighquantumefficiencysensorsthenextchallengeindentaldigitalimaging