Piloting Laboratory Quality System Management in Six Health Facilities in Nigeria

BACKGROUND: Achieving accreditation in laboratories is a challenge in Nigeria like in most African countries. Nigeria adopted the World Health Organization Regional Office for Africa Stepwise Laboratory (Quality) Improvement Process Towards Accreditation (WHO/AFRO– SLIPTA) in 2010. We report on FHI3...

Descripción completa

Detalles Bibliográficos
Autores principales: Mbah, Henry, Ojo, Emmanuel, Ameh, James, Musuluma, Humphrey, Negedu-Momoh, Olubunmi Ruth, Jegede, Feyisayo, Ojo, Olufunmilayo, Uwakwe, Nkem, Ochei, Kingsley, Dada, Michael, Udah, Donald, Chiegil, Robert, Torpey, Kwasi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4277469/
https://www.ncbi.nlm.nih.gov/pubmed/25542022
http://dx.doi.org/10.1371/journal.pone.0116185
Descripción
Sumario:BACKGROUND: Achieving accreditation in laboratories is a challenge in Nigeria like in most African countries. Nigeria adopted the World Health Organization Regional Office for Africa Stepwise Laboratory (Quality) Improvement Process Towards Accreditation (WHO/AFRO– SLIPTA) in 2010. We report on FHI360 effort and progress in piloting WHO-AFRO recognition and accreditation preparedness in six health facility laboratories in five different states of Nigeria. METHOD: Laboratory assessments were conducted at baseline, follow up and exit using the WHO/AFRO– SLIPTA checklist. From the total percentage score obtained, the quality status of laboratories were classified using a zero to five star rating, based on the WHO/AFRO quality improvement stepwise approach. Major interventions include advocacy, capacity building, mentorship and quality improvement projects. RESULTS: At baseline audit, two of the laboratories attained 1- star while the remaining four were at 0- star. At follow up audit one lab was at 1- star, two at 3-star and three at 4-star. At exit audit, four labs were at 4- star, one at 3-star and one at 2-star rating. One laboratory dropped a ‘star’ at exit audit, while others consistently improved. The two weakest elements at baseline; internal audit (4%) and occurrence/incidence management (15%) improved significantly, with an exit score of 76% and 81% respectively. The elements facility and safety was the major strength across board throughout the audit exercise. CONCLUSION: This effort resulted in measurable and positive impact on the laboratories. We recommend further improvement towards a formal international accreditation status and scale up of WHO/AFRO– SLIPTA implementation in Nigeria.