Cargando…

Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes

BACKGROUND: PET/CT scans acquired in the radiotherapy treatment position are typically performed without compensating for respiratory motion. The purpose of this study was to investigate geographic miss of lung tumours due to respiratory motion for target volumes defined on a standard 3D-PET/CT. MET...

Descripción completa

Detalles Bibliográficos
Autores principales: Callahan, Jason, Kron, Tomas, Siva, Shankar, Simoens, Nathalie, Edgar, Amanda, Everitt, Sarah, Schneider, Michal E, Hicks, Rodney J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4278238/
https://www.ncbi.nlm.nih.gov/pubmed/25511904
http://dx.doi.org/10.1186/s13014-014-0291-6
_version_ 1782350490901676032
author Callahan, Jason
Kron, Tomas
Siva, Shankar
Simoens, Nathalie
Edgar, Amanda
Everitt, Sarah
Schneider, Michal E
Hicks, Rodney J
author_facet Callahan, Jason
Kron, Tomas
Siva, Shankar
Simoens, Nathalie
Edgar, Amanda
Everitt, Sarah
Schneider, Michal E
Hicks, Rodney J
author_sort Callahan, Jason
collection PubMed
description BACKGROUND: PET/CT scans acquired in the radiotherapy treatment position are typically performed without compensating for respiratory motion. The purpose of this study was to investigate geographic miss of lung tumours due to respiratory motion for target volumes defined on a standard 3D-PET/CT. METHODS: 29 patients staged for pulmonary malignancy who completed both a 3D-PET/CT and 4D-PET/CT were included. A 3D-Gross Tumour Volume (GTV) was defined on the standard whole body PET/CT scan. Subsequently a 4D-GTV was defined on a 4D-PET/CT MIP. A 5 mm, 10 mm, 15 mm symmetrical and 15×10 mm asymmetrical Planning Target Volume (PTV) was created by expanding the 3D-GTV and 4D-GTV’s. A 3D conformal plan was generated and calculated to cover the 3D-PTV. The 3D plan was transferred to the 4D-PTV and analysed for geographic miss. Three types of miss were measured. Type 1: any part of the 4D-GTV outside the 3D-PTV. Type 2: any part of the 4D-PTV outside the 3D-PTV. Type 3: any part of the 4D-PTV receiving less than 95% of the prescribed dose. The lesion motion was measured to look at the association between lesion motion and geographic miss. RESULTS: When a standard 15 mm or asymmetrical PTV margin was used there were 1/29 (3%) Type 1 misses. This increased 7/29 (24%) for the 10 mm margin and 23/29 (79%) for a 5 mm margin. All patients for all margins had a Type 2 geographic miss. There was a Type 3 miss in 25 out of 29 cases in the 5, 10, and 15 mm PTV margin groups. The asymmetrical margin had one additional Type 3 miss. Pearson analysis showed a correlation (p < 0.01) between lesion motion and the severity of the different types of geographic miss. CONCLUSION: Without any form of motion suppression, the current standard of a 3D- PET/CT and 15 mm PTV margin employed for lung lesions has an increasing risk of significant geographic miss when tumour motion increases. Use of smaller asymmetric margins in the cranio-caudal direction does not comprise tumour coverage. Reducing PTV margins for volumes defined on 3D-PET/CT will greatly increase the chance and severity of a geometric miss due to respiratory motion. 4D-imaging reduces the risk of geographic miss across the population of tumour sizes and magnitude of motion investigated in the study.
format Online
Article
Text
id pubmed-4278238
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42782382014-12-30 Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes Callahan, Jason Kron, Tomas Siva, Shankar Simoens, Nathalie Edgar, Amanda Everitt, Sarah Schneider, Michal E Hicks, Rodney J Radiat Oncol Research BACKGROUND: PET/CT scans acquired in the radiotherapy treatment position are typically performed without compensating for respiratory motion. The purpose of this study was to investigate geographic miss of lung tumours due to respiratory motion for target volumes defined on a standard 3D-PET/CT. METHODS: 29 patients staged for pulmonary malignancy who completed both a 3D-PET/CT and 4D-PET/CT were included. A 3D-Gross Tumour Volume (GTV) was defined on the standard whole body PET/CT scan. Subsequently a 4D-GTV was defined on a 4D-PET/CT MIP. A 5 mm, 10 mm, 15 mm symmetrical and 15×10 mm asymmetrical Planning Target Volume (PTV) was created by expanding the 3D-GTV and 4D-GTV’s. A 3D conformal plan was generated and calculated to cover the 3D-PTV. The 3D plan was transferred to the 4D-PTV and analysed for geographic miss. Three types of miss were measured. Type 1: any part of the 4D-GTV outside the 3D-PTV. Type 2: any part of the 4D-PTV outside the 3D-PTV. Type 3: any part of the 4D-PTV receiving less than 95% of the prescribed dose. The lesion motion was measured to look at the association between lesion motion and geographic miss. RESULTS: When a standard 15 mm or asymmetrical PTV margin was used there were 1/29 (3%) Type 1 misses. This increased 7/29 (24%) for the 10 mm margin and 23/29 (79%) for a 5 mm margin. All patients for all margins had a Type 2 geographic miss. There was a Type 3 miss in 25 out of 29 cases in the 5, 10, and 15 mm PTV margin groups. The asymmetrical margin had one additional Type 3 miss. Pearson analysis showed a correlation (p < 0.01) between lesion motion and the severity of the different types of geographic miss. CONCLUSION: Without any form of motion suppression, the current standard of a 3D- PET/CT and 15 mm PTV margin employed for lung lesions has an increasing risk of significant geographic miss when tumour motion increases. Use of smaller asymmetric margins in the cranio-caudal direction does not comprise tumour coverage. Reducing PTV margins for volumes defined on 3D-PET/CT will greatly increase the chance and severity of a geometric miss due to respiratory motion. 4D-imaging reduces the risk of geographic miss across the population of tumour sizes and magnitude of motion investigated in the study. BioMed Central 2014-12-16 /pmc/articles/PMC4278238/ /pubmed/25511904 http://dx.doi.org/10.1186/s13014-014-0291-6 Text en © Callahan et al.; licensee BioMed Central. 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Callahan, Jason
Kron, Tomas
Siva, Shankar
Simoens, Nathalie
Edgar, Amanda
Everitt, Sarah
Schneider, Michal E
Hicks, Rodney J
Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes
title Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes
title_full Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes
title_fullStr Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes
title_full_unstemmed Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes
title_short Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes
title_sort geographic miss of lung tumours due to respiratory motion: a comparison of 3d vs 4d pet/ct defined target volumes
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4278238/
https://www.ncbi.nlm.nih.gov/pubmed/25511904
http://dx.doi.org/10.1186/s13014-014-0291-6
work_keys_str_mv AT callahanjason geographicmissoflungtumoursduetorespiratorymotionacomparisonof3dvs4dpetctdefinedtargetvolumes
AT krontomas geographicmissoflungtumoursduetorespiratorymotionacomparisonof3dvs4dpetctdefinedtargetvolumes
AT sivashankar geographicmissoflungtumoursduetorespiratorymotionacomparisonof3dvs4dpetctdefinedtargetvolumes
AT simoensnathalie geographicmissoflungtumoursduetorespiratorymotionacomparisonof3dvs4dpetctdefinedtargetvolumes
AT edgaramanda geographicmissoflungtumoursduetorespiratorymotionacomparisonof3dvs4dpetctdefinedtargetvolumes
AT everittsarah geographicmissoflungtumoursduetorespiratorymotionacomparisonof3dvs4dpetctdefinedtargetvolumes
AT schneidermichale geographicmissoflungtumoursduetorespiratorymotionacomparisonof3dvs4dpetctdefinedtargetvolumes
AT hicksrodneyj geographicmissoflungtumoursduetorespiratorymotionacomparisonof3dvs4dpetctdefinedtargetvolumes