Cargando…
The influence of systemically administered oxytocin on the implant-bone interface area: an experimental study in the rabbit
PURPOSE: The purpose of this study was to assess the effect of systemically administered oxytocin (OT) on the implant-bone interface by using histomorphometric analysis and the removal torque test. MATERIALS AND METHODS: A total of 10 adult, New Zealand white, female rabbits were used in this experi...
Autores principales: | Cho, Sung-Am, Park, Sang-Hun, Cho, Jin-Hyun |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4279050/ https://www.ncbi.nlm.nih.gov/pubmed/25551011 http://dx.doi.org/10.4047/jap.2014.6.6.505 |
Ejemplares similares
-
Comparison of removal torques of SLActive® implant and blasted, laser-treated titanium implant in rabbit tibia bone healed with concentrated growth factor application
por: Park, Sang-Hun, et al.
Publicado: (2016) -
THE INFLUENCE OF INTRAVENOUSLY ADMINISTERED SURFACE-ACTIVE AGENTS ON THE DEVELOPMENT OF EXPERIMENTAL ATHEROSCLEROSIS IN RABBITS
por: Kellner, Aaron, et al.
Publicado: (1951) -
Electrophysiological Actions of Oxytocin on the Rabbit Myometrium
por: Kleinhaus, A. L., et al.
Publicado: (1969) -
Comparison of removal torques between laser-treated and SLA-treated implant surfaces in rabbit tibiae
por: Kang, Nam-Seok, et al.
Publicado: (2014) -
The healing effect of platelet-rich plasma on xenograft in peri-implant bone defects in rabbits
por: Peng, Wang, et al.
Publicado: (2016)