Cargando…
The influence of thread geometry on implant osseointegration under immediate loading: a literature review
Implant success is achieved by the synergistic combination of numerous biomechanical factors. This report examines the mechanical aspect of implants. In particular, it is focused on macrodesign such as thread shape, pitch, width and depth, and crestal module of implants. This study reviews the liter...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4279055/ https://www.ncbi.nlm.nih.gov/pubmed/25551016 http://dx.doi.org/10.4047/jap.2014.6.6.547 |
_version_ | 1782350619366916096 |
---|---|
author | Ryu, Hyo-Sook Namgung, Cheol Lee, Jong-Ho Lim, Young-Jun |
author_facet | Ryu, Hyo-Sook Namgung, Cheol Lee, Jong-Ho Lim, Young-Jun |
author_sort | Ryu, Hyo-Sook |
collection | PubMed |
description | Implant success is achieved by the synergistic combination of numerous biomechanical factors. This report examines the mechanical aspect of implants. In particular, it is focused on macrodesign such as thread shape, pitch, width and depth, and crestal module of implants. This study reviews the literature regarding the effect of implant thread geometry on primary stability and osseointegration under immediate loading. The search strategy included both in vitro and in vivo studies published in the MEDLINE database from January 2000 to June 2014. Various geometrical parameters are analyzed to evaluate their significance for optimal stress distribution, implant surface area, and bone remodeling responses during the process of osseointegration. |
format | Online Article Text |
id | pubmed-4279055 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-42790552014-12-30 The influence of thread geometry on implant osseointegration under immediate loading: a literature review Ryu, Hyo-Sook Namgung, Cheol Lee, Jong-Ho Lim, Young-Jun J Adv Prosthodont Original Article Implant success is achieved by the synergistic combination of numerous biomechanical factors. This report examines the mechanical aspect of implants. In particular, it is focused on macrodesign such as thread shape, pitch, width and depth, and crestal module of implants. This study reviews the literature regarding the effect of implant thread geometry on primary stability and osseointegration under immediate loading. The search strategy included both in vitro and in vivo studies published in the MEDLINE database from January 2000 to June 2014. Various geometrical parameters are analyzed to evaluate their significance for optimal stress distribution, implant surface area, and bone remodeling responses during the process of osseointegration. The Korean Academy of Prosthodontics 2014-12 2014-12-17 /pmc/articles/PMC4279055/ /pubmed/25551016 http://dx.doi.org/10.4047/jap.2014.6.6.547 Text en © 2014 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ryu, Hyo-Sook Namgung, Cheol Lee, Jong-Ho Lim, Young-Jun The influence of thread geometry on implant osseointegration under immediate loading: a literature review |
title | The influence of thread geometry on implant osseointegration under immediate loading: a literature review |
title_full | The influence of thread geometry on implant osseointegration under immediate loading: a literature review |
title_fullStr | The influence of thread geometry on implant osseointegration under immediate loading: a literature review |
title_full_unstemmed | The influence of thread geometry on implant osseointegration under immediate loading: a literature review |
title_short | The influence of thread geometry on implant osseointegration under immediate loading: a literature review |
title_sort | influence of thread geometry on implant osseointegration under immediate loading: a literature review |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4279055/ https://www.ncbi.nlm.nih.gov/pubmed/25551016 http://dx.doi.org/10.4047/jap.2014.6.6.547 |
work_keys_str_mv | AT ryuhyosook theinfluenceofthreadgeometryonimplantosseointegrationunderimmediateloadingaliteraturereview AT namgungcheol theinfluenceofthreadgeometryonimplantosseointegrationunderimmediateloadingaliteraturereview AT leejongho theinfluenceofthreadgeometryonimplantosseointegrationunderimmediateloadingaliteraturereview AT limyoungjun theinfluenceofthreadgeometryonimplantosseointegrationunderimmediateloadingaliteraturereview AT ryuhyosook influenceofthreadgeometryonimplantosseointegrationunderimmediateloadingaliteraturereview AT namgungcheol influenceofthreadgeometryonimplantosseointegrationunderimmediateloadingaliteraturereview AT leejongho influenceofthreadgeometryonimplantosseointegrationunderimmediateloadingaliteraturereview AT limyoungjun influenceofthreadgeometryonimplantosseointegrationunderimmediateloadingaliteraturereview |