Cargando…
Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications
This article presents a novel membrane-based sensor for real-time electrochemical investigations of cellular- or tissue cultures. The membrane sensor enables recording of electrical signals from a cell culture without any signal dilution, thus avoiding loss of sensitivity. Moreover, the porosity of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4279581/ https://www.ncbi.nlm.nih.gov/pubmed/25421738 http://dx.doi.org/10.3390/s141122128 |
_version_ | 1782350720854392832 |
---|---|
author | Alatraktchi, Fatima AlZahra'a Bakmand, Tanya Dimaki, Maria Svendsen, Winnie E. |
author_facet | Alatraktchi, Fatima AlZahra'a Bakmand, Tanya Dimaki, Maria Svendsen, Winnie E. |
author_sort | Alatraktchi, Fatima AlZahra'a |
collection | PubMed |
description | This article presents a novel membrane-based sensor for real-time electrochemical investigations of cellular- or tissue cultures. The membrane sensor enables recording of electrical signals from a cell culture without any signal dilution, thus avoiding loss of sensitivity. Moreover, the porosity of the membrane provides optimal culturing conditions similar to existing culturing techniques allowing more efficient nutrient uptake and molecule release. The patterned sensor electrodes were fabricated on a porous membrane by electron-beam evaporation. The electrochemical performance of the membrane electrodes was characterized by cyclic voltammetry and chronoamperometry, and the detection of synthetic dopamine was demonstrated down to a concentration of 3.1 pM. Furthermore, to present the membrane-sensor functionality the dopamine release from cultured PC12 cells was successfully measured. The PC12 cells culturing experiments showed that the membrane-sensor was suitable as a cell culturing substrate for bio-applications. Real-time measurements of dopamine exocytosis in cell cultures were performed, where the transmitter release was recorded at the point of release. The developed membrane-sensor provides a new functionality to the standard culturing methods, enabling sensitive continuous in vitro monitoring and closely mimicking the in vivo conditions. |
format | Online Article Text |
id | pubmed-4279581 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-42795812015-01-15 Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications Alatraktchi, Fatima AlZahra'a Bakmand, Tanya Dimaki, Maria Svendsen, Winnie E. Sensors (Basel) Article This article presents a novel membrane-based sensor for real-time electrochemical investigations of cellular- or tissue cultures. The membrane sensor enables recording of electrical signals from a cell culture without any signal dilution, thus avoiding loss of sensitivity. Moreover, the porosity of the membrane provides optimal culturing conditions similar to existing culturing techniques allowing more efficient nutrient uptake and molecule release. The patterned sensor electrodes were fabricated on a porous membrane by electron-beam evaporation. The electrochemical performance of the membrane electrodes was characterized by cyclic voltammetry and chronoamperometry, and the detection of synthetic dopamine was demonstrated down to a concentration of 3.1 pM. Furthermore, to present the membrane-sensor functionality the dopamine release from cultured PC12 cells was successfully measured. The PC12 cells culturing experiments showed that the membrane-sensor was suitable as a cell culturing substrate for bio-applications. Real-time measurements of dopamine exocytosis in cell cultures were performed, where the transmitter release was recorded at the point of release. The developed membrane-sensor provides a new functionality to the standard culturing methods, enabling sensitive continuous in vitro monitoring and closely mimicking the in vivo conditions. MDPI 2014-11-24 /pmc/articles/PMC4279581/ /pubmed/25421738 http://dx.doi.org/10.3390/s141122128 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Alatraktchi, Fatima AlZahra'a Bakmand, Tanya Dimaki, Maria Svendsen, Winnie E. Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications |
title | Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications |
title_full | Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications |
title_fullStr | Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications |
title_full_unstemmed | Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications |
title_short | Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications |
title_sort | novel membrane-based electrochemical sensor for real-time bio-applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4279581/ https://www.ncbi.nlm.nih.gov/pubmed/25421738 http://dx.doi.org/10.3390/s141122128 |
work_keys_str_mv | AT alatraktchifatimaalzahraa novelmembranebasedelectrochemicalsensorforrealtimebioapplications AT bakmandtanya novelmembranebasedelectrochemicalsensorforrealtimebioapplications AT dimakimaria novelmembranebasedelectrochemicalsensorforrealtimebioapplications AT svendsenwinniee novelmembranebasedelectrochemicalsensorforrealtimebioapplications |