Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications

This article presents a novel membrane-based sensor for real-time electrochemical investigations of cellular- or tissue cultures. The membrane sensor enables recording of electrical signals from a cell culture without any signal dilution, thus avoiding loss of sensitivity. Moreover, the porosity of...

Descripción completa

Detalles Bibliográficos
Autores principales: Alatraktchi, Fatima AlZahra'a, Bakmand, Tanya, Dimaki, Maria, Svendsen, Winnie E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4279581/
https://www.ncbi.nlm.nih.gov/pubmed/25421738
http://dx.doi.org/10.3390/s141122128
_version_ 1782350720854392832
author Alatraktchi, Fatima AlZahra'a
Bakmand, Tanya
Dimaki, Maria
Svendsen, Winnie E.
author_facet Alatraktchi, Fatima AlZahra'a
Bakmand, Tanya
Dimaki, Maria
Svendsen, Winnie E.
author_sort Alatraktchi, Fatima AlZahra'a
collection PubMed
description This article presents a novel membrane-based sensor for real-time electrochemical investigations of cellular- or tissue cultures. The membrane sensor enables recording of electrical signals from a cell culture without any signal dilution, thus avoiding loss of sensitivity. Moreover, the porosity of the membrane provides optimal culturing conditions similar to existing culturing techniques allowing more efficient nutrient uptake and molecule release. The patterned sensor electrodes were fabricated on a porous membrane by electron-beam evaporation. The electrochemical performance of the membrane electrodes was characterized by cyclic voltammetry and chronoamperometry, and the detection of synthetic dopamine was demonstrated down to a concentration of 3.1 pM. Furthermore, to present the membrane-sensor functionality the dopamine release from cultured PC12 cells was successfully measured. The PC12 cells culturing experiments showed that the membrane-sensor was suitable as a cell culturing substrate for bio-applications. Real-time measurements of dopamine exocytosis in cell cultures were performed, where the transmitter release was recorded at the point of release. The developed membrane-sensor provides a new functionality to the standard culturing methods, enabling sensitive continuous in vitro monitoring and closely mimicking the in vivo conditions.
format Online
Article
Text
id pubmed-4279581
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-42795812015-01-15 Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications Alatraktchi, Fatima AlZahra'a Bakmand, Tanya Dimaki, Maria Svendsen, Winnie E. Sensors (Basel) Article This article presents a novel membrane-based sensor for real-time electrochemical investigations of cellular- or tissue cultures. The membrane sensor enables recording of electrical signals from a cell culture without any signal dilution, thus avoiding loss of sensitivity. Moreover, the porosity of the membrane provides optimal culturing conditions similar to existing culturing techniques allowing more efficient nutrient uptake and molecule release. The patterned sensor electrodes were fabricated on a porous membrane by electron-beam evaporation. The electrochemical performance of the membrane electrodes was characterized by cyclic voltammetry and chronoamperometry, and the detection of synthetic dopamine was demonstrated down to a concentration of 3.1 pM. Furthermore, to present the membrane-sensor functionality the dopamine release from cultured PC12 cells was successfully measured. The PC12 cells culturing experiments showed that the membrane-sensor was suitable as a cell culturing substrate for bio-applications. Real-time measurements of dopamine exocytosis in cell cultures were performed, where the transmitter release was recorded at the point of release. The developed membrane-sensor provides a new functionality to the standard culturing methods, enabling sensitive continuous in vitro monitoring and closely mimicking the in vivo conditions. MDPI 2014-11-24 /pmc/articles/PMC4279581/ /pubmed/25421738 http://dx.doi.org/10.3390/s141122128 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Alatraktchi, Fatima AlZahra'a
Bakmand, Tanya
Dimaki, Maria
Svendsen, Winnie E.
Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications
title Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications
title_full Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications
title_fullStr Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications
title_full_unstemmed Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications
title_short Novel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications
title_sort novel membrane-based electrochemical sensor for real-time bio-applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4279581/
https://www.ncbi.nlm.nih.gov/pubmed/25421738
http://dx.doi.org/10.3390/s141122128
work_keys_str_mv AT alatraktchifatimaalzahraa novelmembranebasedelectrochemicalsensorforrealtimebioapplications
AT bakmandtanya novelmembranebasedelectrochemicalsensorforrealtimebioapplications
AT dimakimaria novelmembranebasedelectrochemicalsensorforrealtimebioapplications
AT svendsenwinniee novelmembranebasedelectrochemicalsensorforrealtimebioapplications