Interleaved EPI Based fMRI Improved by Multiplexed Sensitivity Encoding (MUSE) and Simultaneous Multi-Band Imaging

Functional magnetic resonance imaging (fMRI) is a non-invasive and powerful imaging tool for detecting brain activities. The majority of fMRI studies are performed with single-shot echo-planar imaging (EPI) due to its high temporal resolution. Recent studies have demonstrated that, by increasing the...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Hing-Chiu, Gaur, Pooja, Chou, Ying-hui, Chu, Mei-Lan, Chen, Nan-kuei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4280209/
https://www.ncbi.nlm.nih.gov/pubmed/25549271
http://dx.doi.org/10.1371/journal.pone.0116378
_version_ 1782350825622863872
author Chang, Hing-Chiu
Gaur, Pooja
Chou, Ying-hui
Chu, Mei-Lan
Chen, Nan-kuei
author_facet Chang, Hing-Chiu
Gaur, Pooja
Chou, Ying-hui
Chu, Mei-Lan
Chen, Nan-kuei
author_sort Chang, Hing-Chiu
collection PubMed
description Functional magnetic resonance imaging (fMRI) is a non-invasive and powerful imaging tool for detecting brain activities. The majority of fMRI studies are performed with single-shot echo-planar imaging (EPI) due to its high temporal resolution. Recent studies have demonstrated that, by increasing the spatial-resolution of fMRI, previously unidentified neuronal networks can be measured. However, it is challenging to improve the spatial resolution of conventional single-shot EPI based fMRI. Although multi-shot interleaved EPI is superior to single-shot EPI in terms of the improved spatial-resolution, reduced geometric distortions, and sharper point spread function (PSF), interleaved EPI based fMRI has two main limitations: 1) the imaging throughput is lower in interleaved EPI; 2) the magnitude and phase signal variations among EPI segments (due to physiological noise, subject motion, and B(0) drift) are translated to significant in-plane aliasing artifact across the field of view (FOV). Here we report a method that integrates multiple approaches to address the technical limitations of interleaved EPI-based fMRI. Firstly, the multiplexed sensitivity-encoding (MUSE) post-processing algorithm is used to suppress in-plane aliasing artifacts resulting from time-domain signal instabilities during dynamic scans. Secondly, a simultaneous multi-band interleaved EPI pulse sequence, with a controlled aliasing scheme incorporated, is implemented to increase the imaging throughput. Thirdly, the MUSE algorithm is then generalized to accommodate fMRI data obtained with our multi-band interleaved EPI pulse sequence, suppressing both in-plane and through-plane aliasing artifacts. The blood-oxygenation-level-dependent (BOLD) signal detectability and the scan throughput can be significantly improved for interleaved EPI-based fMRI. Our human fMRI data obtained from 3 Tesla systems demonstrate the effectiveness of the developed methods. It is expected that future fMRI studies requiring high spatial-resolvability and fidelity will largely benefit from the reported techniques.
format Online
Article
Text
id pubmed-4280209
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-42802092015-01-07 Interleaved EPI Based fMRI Improved by Multiplexed Sensitivity Encoding (MUSE) and Simultaneous Multi-Band Imaging Chang, Hing-Chiu Gaur, Pooja Chou, Ying-hui Chu, Mei-Lan Chen, Nan-kuei PLoS One Research Article Functional magnetic resonance imaging (fMRI) is a non-invasive and powerful imaging tool for detecting brain activities. The majority of fMRI studies are performed with single-shot echo-planar imaging (EPI) due to its high temporal resolution. Recent studies have demonstrated that, by increasing the spatial-resolution of fMRI, previously unidentified neuronal networks can be measured. However, it is challenging to improve the spatial resolution of conventional single-shot EPI based fMRI. Although multi-shot interleaved EPI is superior to single-shot EPI in terms of the improved spatial-resolution, reduced geometric distortions, and sharper point spread function (PSF), interleaved EPI based fMRI has two main limitations: 1) the imaging throughput is lower in interleaved EPI; 2) the magnitude and phase signal variations among EPI segments (due to physiological noise, subject motion, and B(0) drift) are translated to significant in-plane aliasing artifact across the field of view (FOV). Here we report a method that integrates multiple approaches to address the technical limitations of interleaved EPI-based fMRI. Firstly, the multiplexed sensitivity-encoding (MUSE) post-processing algorithm is used to suppress in-plane aliasing artifacts resulting from time-domain signal instabilities during dynamic scans. Secondly, a simultaneous multi-band interleaved EPI pulse sequence, with a controlled aliasing scheme incorporated, is implemented to increase the imaging throughput. Thirdly, the MUSE algorithm is then generalized to accommodate fMRI data obtained with our multi-band interleaved EPI pulse sequence, suppressing both in-plane and through-plane aliasing artifacts. The blood-oxygenation-level-dependent (BOLD) signal detectability and the scan throughput can be significantly improved for interleaved EPI-based fMRI. Our human fMRI data obtained from 3 Tesla systems demonstrate the effectiveness of the developed methods. It is expected that future fMRI studies requiring high spatial-resolvability and fidelity will largely benefit from the reported techniques. Public Library of Science 2014-12-30 /pmc/articles/PMC4280209/ /pubmed/25549271 http://dx.doi.org/10.1371/journal.pone.0116378 Text en © 2014 Chang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Chang, Hing-Chiu
Gaur, Pooja
Chou, Ying-hui
Chu, Mei-Lan
Chen, Nan-kuei
Interleaved EPI Based fMRI Improved by Multiplexed Sensitivity Encoding (MUSE) and Simultaneous Multi-Band Imaging
title Interleaved EPI Based fMRI Improved by Multiplexed Sensitivity Encoding (MUSE) and Simultaneous Multi-Band Imaging
title_full Interleaved EPI Based fMRI Improved by Multiplexed Sensitivity Encoding (MUSE) and Simultaneous Multi-Band Imaging
title_fullStr Interleaved EPI Based fMRI Improved by Multiplexed Sensitivity Encoding (MUSE) and Simultaneous Multi-Band Imaging
title_full_unstemmed Interleaved EPI Based fMRI Improved by Multiplexed Sensitivity Encoding (MUSE) and Simultaneous Multi-Band Imaging
title_short Interleaved EPI Based fMRI Improved by Multiplexed Sensitivity Encoding (MUSE) and Simultaneous Multi-Band Imaging
title_sort interleaved epi based fmri improved by multiplexed sensitivity encoding (muse) and simultaneous multi-band imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4280209/
https://www.ncbi.nlm.nih.gov/pubmed/25549271
http://dx.doi.org/10.1371/journal.pone.0116378
work_keys_str_mv AT changhingchiu interleavedepibasedfmriimprovedbymultiplexedsensitivityencodingmuseandsimultaneousmultibandimaging
AT gaurpooja interleavedepibasedfmriimprovedbymultiplexedsensitivityencodingmuseandsimultaneousmultibandimaging
AT chouyinghui interleavedepibasedfmriimprovedbymultiplexedsensitivityencodingmuseandsimultaneousmultibandimaging
AT chumeilan interleavedepibasedfmriimprovedbymultiplexedsensitivityencodingmuseandsimultaneousmultibandimaging
AT chennankuei interleavedepibasedfmriimprovedbymultiplexedsensitivityencodingmuseandsimultaneousmultibandimaging