Cargando…

Image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration

INTRODUCTION: For percutaneous abdomen intervention (e.g. liver radiofrequency (RF) tumor ablation, liver biopsy), surgeons lack real-time visual feedback about the location of the needle on planning images, typically computed tomography (CT). One difficulty lies in tracking and synchronizing both t...

Descripción completa

Detalles Bibliográficos
Autor principal: Spinczyk, Dominik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4280415/
https://www.ncbi.nlm.nih.gov/pubmed/25561990
http://dx.doi.org/10.5114/wiitm.2014.45048
_version_ 1782350845287858176
author Spinczyk, Dominik
author_facet Spinczyk, Dominik
author_sort Spinczyk, Dominik
collection PubMed
description INTRODUCTION: For percutaneous abdomen intervention (e.g. liver radiofrequency (RF) tumor ablation, liver biopsy), surgeons lack real-time visual feedback about the location of the needle on planning images, typically computed tomography (CT). One difficulty lies in tracking and synchronizing both the tool movement and the patient breathing motion. AIM: To verify the correspondence between rigid registration fiducial registration error signal and breathing phase. MATERIAL AND METHODS: Designed markers that are clearly visible both in planning CT and on the patient during the intervention are proposed. Registration and breathing synchronization is then performed by a point-based approach. The method was tested in a clinical environment on 10 patients with liver cancer using 3D abdominal CT in the exhale position. Median rigid fiducial registration error (FRE) in the breathing cycle was used as a criterion to distinguish the inhale and exhale phase. RESULTS: The correlation between breathing phase and FRE value can be observed for every patient. We obtained mean median FRE equal to 9.37 mm in exhale positions and 15.56 mm in the whole breathing cycle. CONCLUSIONS: The presented real time approach, based on FRE calculation, was integrated in the clinical pipeline, and can help to select the best respiratory phase for needle insertion for percutaneous abdomen intervention, in cases where only 3D CT is performed. Moreover, this method allows semi-automated rigid registration to establish the correspondence between preoperative patient anatomical model and patient position.
format Online
Article
Text
id pubmed-4280415
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-42804152015-01-05 Image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration Spinczyk, Dominik Wideochir Inne Tech Maloinwazyjne Original Paper INTRODUCTION: For percutaneous abdomen intervention (e.g. liver radiofrequency (RF) tumor ablation, liver biopsy), surgeons lack real-time visual feedback about the location of the needle on planning images, typically computed tomography (CT). One difficulty lies in tracking and synchronizing both the tool movement and the patient breathing motion. AIM: To verify the correspondence between rigid registration fiducial registration error signal and breathing phase. MATERIAL AND METHODS: Designed markers that are clearly visible both in planning CT and on the patient during the intervention are proposed. Registration and breathing synchronization is then performed by a point-based approach. The method was tested in a clinical environment on 10 patients with liver cancer using 3D abdominal CT in the exhale position. Median rigid fiducial registration error (FRE) in the breathing cycle was used as a criterion to distinguish the inhale and exhale phase. RESULTS: The correlation between breathing phase and FRE value can be observed for every patient. We obtained mean median FRE equal to 9.37 mm in exhale positions and 15.56 mm in the whole breathing cycle. CONCLUSIONS: The presented real time approach, based on FRE calculation, was integrated in the clinical pipeline, and can help to select the best respiratory phase for needle insertion for percutaneous abdomen intervention, in cases where only 3D CT is performed. Moreover, this method allows semi-automated rigid registration to establish the correspondence between preoperative patient anatomical model and patient position. Termedia Publishing House 2014-09-05 2014-12 /pmc/articles/PMC4280415/ /pubmed/25561990 http://dx.doi.org/10.5114/wiitm.2014.45048 Text en Copyright © 2014 Sekcja Wideochirurgii TChP http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Spinczyk, Dominik
Image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration
title Image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration
title_full Image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration
title_fullStr Image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration
title_full_unstemmed Image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration
title_short Image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration
title_sort image-based guidance of percutaneous abdomen intervention based on markers for semi-automatic rigid registration
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4280415/
https://www.ncbi.nlm.nih.gov/pubmed/25561990
http://dx.doi.org/10.5114/wiitm.2014.45048
work_keys_str_mv AT spinczykdominik imagebasedguidanceofpercutaneousabdomeninterventionbasedonmarkersforsemiautomaticrigidregistration