Cargando…

The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study

BACKGROUND: To investigate the influence of scan distance on retinal boundary detection errors (RBDEs) and retinal thickness measurements by spectral domain optical coherence tomography (SD-OCT). METHODS: 10 eyes of healthy subjects, 10 eyes with diabetic macular edema (DME) and 10 eyes with neovasc...

Descripción completa

Detalles Bibliográficos
Autores principales: Varga, Boglárka Enikő, Tátrai, Erika, Cabrera DeBuc, Delia, Somfai, Gábor Márk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4280767/
https://www.ncbi.nlm.nih.gov/pubmed/25428608
http://dx.doi.org/10.1186/1471-2415-14-148
_version_ 1782350897397891072
author Varga, Boglárka Enikő
Tátrai, Erika
Cabrera DeBuc, Delia
Somfai, Gábor Márk
author_facet Varga, Boglárka Enikő
Tátrai, Erika
Cabrera DeBuc, Delia
Somfai, Gábor Márk
author_sort Varga, Boglárka Enikő
collection PubMed
description BACKGROUND: To investigate the influence of scan distance on retinal boundary detection errors (RBDEs) and retinal thickness measurements by spectral domain optical coherence tomography (SD-OCT). METHODS: 10 eyes of healthy subjects, 10 eyes with diabetic macular edema (DME) and 10 eyes with neovascular age-related macular degeneration (AMD) were examined with RTVue SD-OCT. The MM5 protocol was used in two consecutive sessions to scan the macula. For the first session, the device was set 3.5 cm from the eye in order to obtain detectable signal with low fundus image quality (suboptimal setting) while in the second session a distance of 2.5 cm was set with a good quality fundus image. The signal strength (SSI) value was recorded. The score for retinal boundary detection errors (RBDE) was calculated for ten scans of each examination. RBDE scores were recorded for the whole scan and also for the peripheral 1.0 mm region. RBDE scores, regional retinal thickness values and SSI values between the two sessions were compared. The correlation between SSI and the number of RBDEs was also examined. RESULTS: The SSI was significantly lower with suboptimal settings compared to optimal settings (63.9±12.0 vs. 68.3±12.2, respectively, p = 0.001) and the number of RBDEs was significantly higher with suboptimal settings in the “all-eyes” group along with the group of healthy subjects and eyes with DME (9.1±6.5 vs. 6.8±6.3, p = 0.007; 4.4±2.6 vs. 2.5±1.6, p = 0.035 and 9.7±3.3 vs. 5.1±3.7, p = 0.008, respectively). For these groups, significant negative correlation was found between the SSI and the number of RBDEs. In the AMD group, the number of RBDEs was markedly higher compared to the other groups and there was no difference in RBDEs between optimal and suboptimal settings with the errors being independent of the SSI. There were significantly less peripheral RBDEs with optimal settings in the “all-eyes” group and the DME subgroup (2.7±2.6 vs. 4.2±2.8, p = 0.001 and 1.4±1.7 vs. 4.1±2.2, p = 0.007, respectively). Retinal thickness in the two settings was significantly different only in the outer-superior region in DME. CONCLUSIONS: Optimal distance settings improve SD-OCT SSI with a decrease in RBDEs while retinal thickness measurements are independent of scanning distance.
format Online
Article
Text
id pubmed-4280767
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42807672015-01-01 The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study Varga, Boglárka Enikő Tátrai, Erika Cabrera DeBuc, Delia Somfai, Gábor Márk BMC Ophthalmol Research Article BACKGROUND: To investigate the influence of scan distance on retinal boundary detection errors (RBDEs) and retinal thickness measurements by spectral domain optical coherence tomography (SD-OCT). METHODS: 10 eyes of healthy subjects, 10 eyes with diabetic macular edema (DME) and 10 eyes with neovascular age-related macular degeneration (AMD) were examined with RTVue SD-OCT. The MM5 protocol was used in two consecutive sessions to scan the macula. For the first session, the device was set 3.5 cm from the eye in order to obtain detectable signal with low fundus image quality (suboptimal setting) while in the second session a distance of 2.5 cm was set with a good quality fundus image. The signal strength (SSI) value was recorded. The score for retinal boundary detection errors (RBDE) was calculated for ten scans of each examination. RBDE scores were recorded for the whole scan and also for the peripheral 1.0 mm region. RBDE scores, regional retinal thickness values and SSI values between the two sessions were compared. The correlation between SSI and the number of RBDEs was also examined. RESULTS: The SSI was significantly lower with suboptimal settings compared to optimal settings (63.9±12.0 vs. 68.3±12.2, respectively, p = 0.001) and the number of RBDEs was significantly higher with suboptimal settings in the “all-eyes” group along with the group of healthy subjects and eyes with DME (9.1±6.5 vs. 6.8±6.3, p = 0.007; 4.4±2.6 vs. 2.5±1.6, p = 0.035 and 9.7±3.3 vs. 5.1±3.7, p = 0.008, respectively). For these groups, significant negative correlation was found between the SSI and the number of RBDEs. In the AMD group, the number of RBDEs was markedly higher compared to the other groups and there was no difference in RBDEs between optimal and suboptimal settings with the errors being independent of the SSI. There were significantly less peripheral RBDEs with optimal settings in the “all-eyes” group and the DME subgroup (2.7±2.6 vs. 4.2±2.8, p = 0.001 and 1.4±1.7 vs. 4.1±2.2, p = 0.007, respectively). Retinal thickness in the two settings was significantly different only in the outer-superior region in DME. CONCLUSIONS: Optimal distance settings improve SD-OCT SSI with a decrease in RBDEs while retinal thickness measurements are independent of scanning distance. BioMed Central 2014-11-27 /pmc/articles/PMC4280767/ /pubmed/25428608 http://dx.doi.org/10.1186/1471-2415-14-148 Text en © Varga et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Varga, Boglárka Enikő
Tátrai, Erika
Cabrera DeBuc, Delia
Somfai, Gábor Márk
The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study
title The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study
title_full The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study
title_fullStr The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study
title_full_unstemmed The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study
title_short The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study
title_sort effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4280767/
https://www.ncbi.nlm.nih.gov/pubmed/25428608
http://dx.doi.org/10.1186/1471-2415-14-148
work_keys_str_mv AT vargaboglarkaeniko theeffectofincorrectscanningdistanceonboundarydetectionerrorsandmacularthicknessmeasurementsbyspectraldomainopticalcoherencetomographyacrosssectionalstudy
AT tatraierika theeffectofincorrectscanningdistanceonboundarydetectionerrorsandmacularthicknessmeasurementsbyspectraldomainopticalcoherencetomographyacrosssectionalstudy
AT cabreradebucdelia theeffectofincorrectscanningdistanceonboundarydetectionerrorsandmacularthicknessmeasurementsbyspectraldomainopticalcoherencetomographyacrosssectionalstudy
AT somfaigabormark theeffectofincorrectscanningdistanceonboundarydetectionerrorsandmacularthicknessmeasurementsbyspectraldomainopticalcoherencetomographyacrosssectionalstudy
AT vargaboglarkaeniko effectofincorrectscanningdistanceonboundarydetectionerrorsandmacularthicknessmeasurementsbyspectraldomainopticalcoherencetomographyacrosssectionalstudy
AT tatraierika effectofincorrectscanningdistanceonboundarydetectionerrorsandmacularthicknessmeasurementsbyspectraldomainopticalcoherencetomographyacrosssectionalstudy
AT cabreradebucdelia effectofincorrectscanningdistanceonboundarydetectionerrorsandmacularthicknessmeasurementsbyspectraldomainopticalcoherencetomographyacrosssectionalstudy
AT somfaigabormark effectofincorrectscanningdistanceonboundarydetectionerrorsandmacularthicknessmeasurementsbyspectraldomainopticalcoherencetomographyacrosssectionalstudy