Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation
OBJECTIVE: Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to acc...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tehran University of Medical Sciences
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4283746/ https://www.ncbi.nlm.nih.gov/pubmed/25584056 |
_version_ | 1782351317692317696 |
---|---|
author | Honardar, Kiamars Assadian, Hadi Shahab, Shahriar Jafari, Zahra Kazemi, Ali Nazarimoghaddam, Kiumars Kharrazifard, Mohammad Javad Labbaf, Hossein |
author_facet | Honardar, Kiamars Assadian, Hadi Shahab, Shahriar Jafari, Zahra Kazemi, Ali Nazarimoghaddam, Kiumars Kharrazifard, Mohammad Javad Labbaf, Hossein |
author_sort | Honardar, Kiamars |
collection | PubMed |
description | OBJECTIVE: Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to compare canal centering ability and transportation of Twisted File and BioRaCe rotary systems by means of cone-beam computed tomography. MATERIALS AND METHODS: Thirty root canals from freshly extracted mandibular and maxillary teeth were selected. Teeth were mounted and scanned before and after preparation by CBCT at different apical levels. Specimens were divided into 2 groups of 15. In the first group Twisted File and in the second, BioRaCe was used for canal preparation. Canal transportation and centering ability after preparation were assessed by NNT Viewer and Photoshop CS4 software. Statistical analysis was performed using t-test and two-way ANOVA. RESULTS: All samples showed deviations from the original axes of the canals. No significant differences were detected between the two rotary NiTi instruments for canal centering ability in all sections. Regarding canal transportation however, a significant difference was seen in the BioRaCe group at 7.5mm from the apex. CONCLUSION: Under the conditions of this in vitro study, Twisted File and BioRaCe rotary NiTi files retained original canal geometry. |
format | Online Article Text |
id | pubmed-4283746 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Tehran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-42837462015-01-12 Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation Honardar, Kiamars Assadian, Hadi Shahab, Shahriar Jafari, Zahra Kazemi, Ali Nazarimoghaddam, Kiumars Kharrazifard, Mohammad Javad Labbaf, Hossein J Dent (Tehran) Original Article OBJECTIVE: Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to compare canal centering ability and transportation of Twisted File and BioRaCe rotary systems by means of cone-beam computed tomography. MATERIALS AND METHODS: Thirty root canals from freshly extracted mandibular and maxillary teeth were selected. Teeth were mounted and scanned before and after preparation by CBCT at different apical levels. Specimens were divided into 2 groups of 15. In the first group Twisted File and in the second, BioRaCe was used for canal preparation. Canal transportation and centering ability after preparation were assessed by NNT Viewer and Photoshop CS4 software. Statistical analysis was performed using t-test and two-way ANOVA. RESULTS: All samples showed deviations from the original axes of the canals. No significant differences were detected between the two rotary NiTi instruments for canal centering ability in all sections. Regarding canal transportation however, a significant difference was seen in the BioRaCe group at 7.5mm from the apex. CONCLUSION: Under the conditions of this in vitro study, Twisted File and BioRaCe rotary NiTi files retained original canal geometry. Tehran University of Medical Sciences 2014-07 2014-07-31 /pmc/articles/PMC4283746/ /pubmed/25584056 Text en Copyright © Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Honardar, Kiamars Assadian, Hadi Shahab, Shahriar Jafari, Zahra Kazemi, Ali Nazarimoghaddam, Kiumars Kharrazifard, Mohammad Javad Labbaf, Hossein Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation |
title | Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation |
title_full | Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation |
title_fullStr | Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation |
title_full_unstemmed | Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation |
title_short | Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation |
title_sort | cone-beam computed tomographic assessment of canal centering ability and transportation after preparation with twisted file and bio race instrumentation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4283746/ https://www.ncbi.nlm.nih.gov/pubmed/25584056 |
work_keys_str_mv | AT honardarkiamars conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation AT assadianhadi conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation AT shahabshahriar conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation AT jafarizahra conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation AT kazemiali conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation AT nazarimoghaddamkiumars conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation AT kharrazifardmohammadjavad conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation AT labbafhossein conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation |