Cargando…

Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation

OBJECTIVE: Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to acc...

Descripción completa

Detalles Bibliográficos
Autores principales: Honardar, Kiamars, Assadian, Hadi, Shahab, Shahriar, Jafari, Zahra, Kazemi, Ali, Nazarimoghaddam, Kiumars, Kharrazifard, Mohammad Javad, Labbaf, Hossein
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4283746/
https://www.ncbi.nlm.nih.gov/pubmed/25584056
_version_ 1782351317692317696
author Honardar, Kiamars
Assadian, Hadi
Shahab, Shahriar
Jafari, Zahra
Kazemi, Ali
Nazarimoghaddam, Kiumars
Kharrazifard, Mohammad Javad
Labbaf, Hossein
author_facet Honardar, Kiamars
Assadian, Hadi
Shahab, Shahriar
Jafari, Zahra
Kazemi, Ali
Nazarimoghaddam, Kiumars
Kharrazifard, Mohammad Javad
Labbaf, Hossein
author_sort Honardar, Kiamars
collection PubMed
description OBJECTIVE: Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to compare canal centering ability and transportation of Twisted File and BioRaCe rotary systems by means of cone-beam computed tomography. MATERIALS AND METHODS: Thirty root canals from freshly extracted mandibular and maxillary teeth were selected. Teeth were mounted and scanned before and after preparation by CBCT at different apical levels. Specimens were divided into 2 groups of 15. In the first group Twisted File and in the second, BioRaCe was used for canal preparation. Canal transportation and centering ability after preparation were assessed by NNT Viewer and Photoshop CS4 software. Statistical analysis was performed using t-test and two-way ANOVA. RESULTS: All samples showed deviations from the original axes of the canals. No significant differences were detected between the two rotary NiTi instruments for canal centering ability in all sections. Regarding canal transportation however, a significant difference was seen in the BioRaCe group at 7.5mm from the apex. CONCLUSION: Under the conditions of this in vitro study, Twisted File and BioRaCe rotary NiTi files retained original canal geometry.
format Online
Article
Text
id pubmed-4283746
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-42837462015-01-12 Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation Honardar, Kiamars Assadian, Hadi Shahab, Shahriar Jafari, Zahra Kazemi, Ali Nazarimoghaddam, Kiumars Kharrazifard, Mohammad Javad Labbaf, Hossein J Dent (Tehran) Original Article OBJECTIVE: Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to compare canal centering ability and transportation of Twisted File and BioRaCe rotary systems by means of cone-beam computed tomography. MATERIALS AND METHODS: Thirty root canals from freshly extracted mandibular and maxillary teeth were selected. Teeth were mounted and scanned before and after preparation by CBCT at different apical levels. Specimens were divided into 2 groups of 15. In the first group Twisted File and in the second, BioRaCe was used for canal preparation. Canal transportation and centering ability after preparation were assessed by NNT Viewer and Photoshop CS4 software. Statistical analysis was performed using t-test and two-way ANOVA. RESULTS: All samples showed deviations from the original axes of the canals. No significant differences were detected between the two rotary NiTi instruments for canal centering ability in all sections. Regarding canal transportation however, a significant difference was seen in the BioRaCe group at 7.5mm from the apex. CONCLUSION: Under the conditions of this in vitro study, Twisted File and BioRaCe rotary NiTi files retained original canal geometry. Tehran University of Medical Sciences 2014-07 2014-07-31 /pmc/articles/PMC4283746/ /pubmed/25584056 Text en Copyright © Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Honardar, Kiamars
Assadian, Hadi
Shahab, Shahriar
Jafari, Zahra
Kazemi, Ali
Nazarimoghaddam, Kiumars
Kharrazifard, Mohammad Javad
Labbaf, Hossein
Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation
title Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation
title_full Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation
title_fullStr Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation
title_full_unstemmed Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation
title_short Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation
title_sort cone-beam computed tomographic assessment of canal centering ability and transportation after preparation with twisted file and bio race instrumentation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4283746/
https://www.ncbi.nlm.nih.gov/pubmed/25584056
work_keys_str_mv AT honardarkiamars conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT assadianhadi conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT shahabshahriar conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT jafarizahra conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT kazemiali conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT nazarimoghaddamkiumars conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT kharrazifardmohammadjavad conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation
AT labbafhossein conebeamcomputedtomographicassessmentofcanalcenteringabilityandtransportationafterpreparationwithtwistedfileandbioraceinstrumentation