A novel high vacuum chest drainage system – a pilot study*
AIM: To assess the safety and feasibility of use of a novel high vacuum chest drainage system (HVCDS) and its influence on the cardiovascular system compared to a conventional system (CCDS). MATERIAL AND METHODS: Five anesthetized pigs underwent a median sternotomy. Three drains were placed in retro...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4283892/ https://www.ncbi.nlm.nih.gov/pubmed/26336441 http://dx.doi.org/10.5114/kitp.2014.45683 |
_version_ | 1782351334696026112 |
---|---|
author | Mrówczyński, Wojciech Tille, Jean-Christophe Khabiri, Ebrahim Giliberto, Jean-Pierre Courvoisier, Delphine S. Kalangos, Afksendiyos Walpoth, Beat H. |
author_facet | Mrówczyński, Wojciech Tille, Jean-Christophe Khabiri, Ebrahim Giliberto, Jean-Pierre Courvoisier, Delphine S. Kalangos, Afksendiyos Walpoth, Beat H. |
author_sort | Mrówczyński, Wojciech |
collection | PubMed |
description | AIM: To assess the safety and feasibility of use of a novel high vacuum chest drainage system (HVCDS) and its influence on the cardiovascular system compared to a conventional system (CCDS). MATERIAL AND METHODS: Five anesthetized pigs underwent a median sternotomy. Three drains were placed in retrocardiac, retrosternal and left pleural positions. The animals received a HVCDS (22 Fr with 180 2-mm holes, n = 2) or a CCDS (n = 2). In the fifth animal off pump coronary artery bypass graft (OPCABG) stabilizers were tested. After chest closure animals had three 30 min runs of artificial bleeding (5 ml/min) under different negative aspiration pressures (–2, –20, –40 kPa) for both groups, followed by standardized surgical bleeding (–40 kPa – HVCDS, – 2 kPa – CCDS). Hemodynamic parameters and each drain's output were registered every 5 minutes and the residual blood was assessed. All catheters, the heart and left lung underwent macroscopic and histopathological examination. RESULTS: The application of the different pressures showed neither hemodynamic changes nor differences in blood drainage with both systems in two bleeding models. The HVCDS enabled drainage comparable to the CCDS but showed relevant clotting. Application of –20 kPa and –40 kPa caused macroscopic epicardial and pulmonary lesions in all tested devices including OPCABG stabilizers consisting of sub-epicardial or sub-pleural hemorrhage without myocyte or alveolar damage. CONCLUSIONS: The novel and conventional chest drainage systems used at pressures up to 40 kPa induced no hemodynamic instability. Both systems showed adequate equal drainage, despite major HVCDS clotting. High negative pressure drainage with both systems showed focal sub-epicardial and subpleural hemorrhage. Thus, long-term assessment of high pressure drainage and potential interaction with fragile structures (coronary bypass graft) should be carried out. |
format | Online Article Text |
id | pubmed-4283892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-42838922015-09-02 A novel high vacuum chest drainage system – a pilot study* Mrówczyński, Wojciech Tille, Jean-Christophe Khabiri, Ebrahim Giliberto, Jean-Pierre Courvoisier, Delphine S. Kalangos, Afksendiyos Walpoth, Beat H. Kardiochir Torakochirurgia Pol Experimental Cardiovascular and Lung Research AIM: To assess the safety and feasibility of use of a novel high vacuum chest drainage system (HVCDS) and its influence on the cardiovascular system compared to a conventional system (CCDS). MATERIAL AND METHODS: Five anesthetized pigs underwent a median sternotomy. Three drains were placed in retrocardiac, retrosternal and left pleural positions. The animals received a HVCDS (22 Fr with 180 2-mm holes, n = 2) or a CCDS (n = 2). In the fifth animal off pump coronary artery bypass graft (OPCABG) stabilizers were tested. After chest closure animals had three 30 min runs of artificial bleeding (5 ml/min) under different negative aspiration pressures (–2, –20, –40 kPa) for both groups, followed by standardized surgical bleeding (–40 kPa – HVCDS, – 2 kPa – CCDS). Hemodynamic parameters and each drain's output were registered every 5 minutes and the residual blood was assessed. All catheters, the heart and left lung underwent macroscopic and histopathological examination. RESULTS: The application of the different pressures showed neither hemodynamic changes nor differences in blood drainage with both systems in two bleeding models. The HVCDS enabled drainage comparable to the CCDS but showed relevant clotting. Application of –20 kPa and –40 kPa caused macroscopic epicardial and pulmonary lesions in all tested devices including OPCABG stabilizers consisting of sub-epicardial or sub-pleural hemorrhage without myocyte or alveolar damage. CONCLUSIONS: The novel and conventional chest drainage systems used at pressures up to 40 kPa induced no hemodynamic instability. Both systems showed adequate equal drainage, despite major HVCDS clotting. High negative pressure drainage with both systems showed focal sub-epicardial and subpleural hemorrhage. Thus, long-term assessment of high pressure drainage and potential interaction with fragile structures (coronary bypass graft) should be carried out. Termedia Publishing House 2014-09-28 2014-09 /pmc/articles/PMC4283892/ /pubmed/26336441 http://dx.doi.org/10.5114/kitp.2014.45683 Text en Copyright © 2014 http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Experimental Cardiovascular and Lung Research Mrówczyński, Wojciech Tille, Jean-Christophe Khabiri, Ebrahim Giliberto, Jean-Pierre Courvoisier, Delphine S. Kalangos, Afksendiyos Walpoth, Beat H. A novel high vacuum chest drainage system – a pilot study* |
title | A novel high vacuum chest drainage system – a pilot study* |
title_full | A novel high vacuum chest drainage system – a pilot study* |
title_fullStr | A novel high vacuum chest drainage system – a pilot study* |
title_full_unstemmed | A novel high vacuum chest drainage system – a pilot study* |
title_short | A novel high vacuum chest drainage system – a pilot study* |
title_sort | novel high vacuum chest drainage system – a pilot study* |
topic | Experimental Cardiovascular and Lung Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4283892/ https://www.ncbi.nlm.nih.gov/pubmed/26336441 http://dx.doi.org/10.5114/kitp.2014.45683 |
work_keys_str_mv | AT mrowczynskiwojciech anovelhighvacuumchestdrainagesystemapilotstudy AT tillejeanchristophe anovelhighvacuumchestdrainagesystemapilotstudy AT khabiriebrahim anovelhighvacuumchestdrainagesystemapilotstudy AT gilibertojeanpierre anovelhighvacuumchestdrainagesystemapilotstudy AT courvoisierdelphines anovelhighvacuumchestdrainagesystemapilotstudy AT kalangosafksendiyos anovelhighvacuumchestdrainagesystemapilotstudy AT walpothbeath anovelhighvacuumchestdrainagesystemapilotstudy AT mrowczynskiwojciech novelhighvacuumchestdrainagesystemapilotstudy AT tillejeanchristophe novelhighvacuumchestdrainagesystemapilotstudy AT khabiriebrahim novelhighvacuumchestdrainagesystemapilotstudy AT gilibertojeanpierre novelhighvacuumchestdrainagesystemapilotstudy AT courvoisierdelphines novelhighvacuumchestdrainagesystemapilotstudy AT kalangosafksendiyos novelhighvacuumchestdrainagesystemapilotstudy AT walpothbeath novelhighvacuumchestdrainagesystemapilotstudy |