Cargando…

A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts

BACKGROUND: Orthosiphon stamineus Benth. (Lamiaceae) is a traditional medicinal plant which has been used in treating various ailments such as kidney diseases, bladder inflammation, arthritis and diabetes. The leaves contain high concentration of phenolic compounds, thus, rosmarinic acid (RA), 3’-hy...

Descripción completa

Detalles Bibliográficos
Autores principales: Saidan, Noor Hafizoh, Aisha, Abdalrahim F.A., Hamil, Mohd Shahrul Ridzuan, Majid, Amin Malik Shah Abdul, Ismail, Zhari
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4285645/
https://www.ncbi.nlm.nih.gov/pubmed/25598631
http://dx.doi.org/10.4103/0974-8490.147195
_version_ 1782351581667131392
author Saidan, Noor Hafizoh
Aisha, Abdalrahim F.A.
Hamil, Mohd Shahrul Ridzuan
Majid, Amin Malik Shah Abdul
Ismail, Zhari
author_facet Saidan, Noor Hafizoh
Aisha, Abdalrahim F.A.
Hamil, Mohd Shahrul Ridzuan
Majid, Amin Malik Shah Abdul
Ismail, Zhari
author_sort Saidan, Noor Hafizoh
collection PubMed
description BACKGROUND: Orthosiphon stamineus Benth. (Lamiaceae) is a traditional medicinal plant which has been used in treating various ailments such as kidney diseases, bladder inflammation, arthritis and diabetes. The leaves contain high concentration of phenolic compounds, thus, rosmarinic acid (RA), 3’-hydroxy-5, 6, 7, 4’-tetramethoxyflavone (TMF), sinensetin (SIN) and eupatorin (EUP) were chosen as a marker compounds for standardization of various O. stamineus leaf extracts. OBJECTIVE: The aim was to develop and validate a new high-performance liquid chromatography (HPLC) method for quantification of 4 marker compounds (RA, TMF, SIN, EUP) in various O. stamineus leaf extracts. MATERIALS AND METHODS: The method was developed and validated using RP-HPLC-diode-array detection at 320 nm for accuracy, precision and limits of detection and was applied for quantification of it markers in five different extracts prepared in solvents with increasing polarity, using a gradient mobile phase 0.1% formic acid: Acetonitrile at a flow rate of 1 ml/min on reverse phase acclaim polar advantage II C18 column (3 μm, 3 × 150 mm) with 18 min separation time. RESULTS: The developed method provided satisfactory precision, and the accuracy of this method was in the range of 90.2% to 105.5%. All of 4 compounds showed good linearity at R2 > 0.999. CONCLUSION: The developed method is a simple, cost effective with shorter run time (18 min) in comparison to previous methods (30 min) and utilization of environmental-friendly solvents system. Therefore, this method has the potential to replace currently used methods in the routine standardization work of O. stamineus extracts, raw materials and its commercial products.
format Online
Article
Text
id pubmed-4285645
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-42856452015-01-16 A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts Saidan, Noor Hafizoh Aisha, Abdalrahim F.A. Hamil, Mohd Shahrul Ridzuan Majid, Amin Malik Shah Abdul Ismail, Zhari Pharmacognosy Res Original Article BACKGROUND: Orthosiphon stamineus Benth. (Lamiaceae) is a traditional medicinal plant which has been used in treating various ailments such as kidney diseases, bladder inflammation, arthritis and diabetes. The leaves contain high concentration of phenolic compounds, thus, rosmarinic acid (RA), 3’-hydroxy-5, 6, 7, 4’-tetramethoxyflavone (TMF), sinensetin (SIN) and eupatorin (EUP) were chosen as a marker compounds for standardization of various O. stamineus leaf extracts. OBJECTIVE: The aim was to develop and validate a new high-performance liquid chromatography (HPLC) method for quantification of 4 marker compounds (RA, TMF, SIN, EUP) in various O. stamineus leaf extracts. MATERIALS AND METHODS: The method was developed and validated using RP-HPLC-diode-array detection at 320 nm for accuracy, precision and limits of detection and was applied for quantification of it markers in five different extracts prepared in solvents with increasing polarity, using a gradient mobile phase 0.1% formic acid: Acetonitrile at a flow rate of 1 ml/min on reverse phase acclaim polar advantage II C18 column (3 μm, 3 × 150 mm) with 18 min separation time. RESULTS: The developed method provided satisfactory precision, and the accuracy of this method was in the range of 90.2% to 105.5%. All of 4 compounds showed good linearity at R2 > 0.999. CONCLUSION: The developed method is a simple, cost effective with shorter run time (18 min) in comparison to previous methods (30 min) and utilization of environmental-friendly solvents system. Therefore, this method has the potential to replace currently used methods in the routine standardization work of O. stamineus extracts, raw materials and its commercial products. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4285645/ /pubmed/25598631 http://dx.doi.org/10.4103/0974-8490.147195 Text en Copyright: © Pharmacognosy Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Saidan, Noor Hafizoh
Aisha, Abdalrahim F.A.
Hamil, Mohd Shahrul Ridzuan
Majid, Amin Malik Shah Abdul
Ismail, Zhari
A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts
title A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts
title_full A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts
title_fullStr A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts
title_full_unstemmed A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts
title_short A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts
title_sort novel reverse phase high-performance liquid chromatography method for standardization of orthosiphon stamineus leaf extracts
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4285645/
https://www.ncbi.nlm.nih.gov/pubmed/25598631
http://dx.doi.org/10.4103/0974-8490.147195
work_keys_str_mv AT saidannoorhafizoh anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT aishaabdalrahimfa anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT hamilmohdshahrulridzuan anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT majidaminmalikshahabdul anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT ismailzhari anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT saidannoorhafizoh novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT aishaabdalrahimfa novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT hamilmohdshahrulridzuan novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT majidaminmalikshahabdul novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts
AT ismailzhari novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts