Cargando…
A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts
BACKGROUND: Orthosiphon stamineus Benth. (Lamiaceae) is a traditional medicinal plant which has been used in treating various ailments such as kidney diseases, bladder inflammation, arthritis and diabetes. The leaves contain high concentration of phenolic compounds, thus, rosmarinic acid (RA), 3’-hy...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4285645/ https://www.ncbi.nlm.nih.gov/pubmed/25598631 http://dx.doi.org/10.4103/0974-8490.147195 |
_version_ | 1782351581667131392 |
---|---|
author | Saidan, Noor Hafizoh Aisha, Abdalrahim F.A. Hamil, Mohd Shahrul Ridzuan Majid, Amin Malik Shah Abdul Ismail, Zhari |
author_facet | Saidan, Noor Hafizoh Aisha, Abdalrahim F.A. Hamil, Mohd Shahrul Ridzuan Majid, Amin Malik Shah Abdul Ismail, Zhari |
author_sort | Saidan, Noor Hafizoh |
collection | PubMed |
description | BACKGROUND: Orthosiphon stamineus Benth. (Lamiaceae) is a traditional medicinal plant which has been used in treating various ailments such as kidney diseases, bladder inflammation, arthritis and diabetes. The leaves contain high concentration of phenolic compounds, thus, rosmarinic acid (RA), 3’-hydroxy-5, 6, 7, 4’-tetramethoxyflavone (TMF), sinensetin (SIN) and eupatorin (EUP) were chosen as a marker compounds for standardization of various O. stamineus leaf extracts. OBJECTIVE: The aim was to develop and validate a new high-performance liquid chromatography (HPLC) method for quantification of 4 marker compounds (RA, TMF, SIN, EUP) in various O. stamineus leaf extracts. MATERIALS AND METHODS: The method was developed and validated using RP-HPLC-diode-array detection at 320 nm for accuracy, precision and limits of detection and was applied for quantification of it markers in five different extracts prepared in solvents with increasing polarity, using a gradient mobile phase 0.1% formic acid: Acetonitrile at a flow rate of 1 ml/min on reverse phase acclaim polar advantage II C18 column (3 μm, 3 × 150 mm) with 18 min separation time. RESULTS: The developed method provided satisfactory precision, and the accuracy of this method was in the range of 90.2% to 105.5%. All of 4 compounds showed good linearity at R2 > 0.999. CONCLUSION: The developed method is a simple, cost effective with shorter run time (18 min) in comparison to previous methods (30 min) and utilization of environmental-friendly solvents system. Therefore, this method has the potential to replace currently used methods in the routine standardization work of O. stamineus extracts, raw materials and its commercial products. |
format | Online Article Text |
id | pubmed-4285645 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-42856452015-01-16 A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts Saidan, Noor Hafizoh Aisha, Abdalrahim F.A. Hamil, Mohd Shahrul Ridzuan Majid, Amin Malik Shah Abdul Ismail, Zhari Pharmacognosy Res Original Article BACKGROUND: Orthosiphon stamineus Benth. (Lamiaceae) is a traditional medicinal plant which has been used in treating various ailments such as kidney diseases, bladder inflammation, arthritis and diabetes. The leaves contain high concentration of phenolic compounds, thus, rosmarinic acid (RA), 3’-hydroxy-5, 6, 7, 4’-tetramethoxyflavone (TMF), sinensetin (SIN) and eupatorin (EUP) were chosen as a marker compounds for standardization of various O. stamineus leaf extracts. OBJECTIVE: The aim was to develop and validate a new high-performance liquid chromatography (HPLC) method for quantification of 4 marker compounds (RA, TMF, SIN, EUP) in various O. stamineus leaf extracts. MATERIALS AND METHODS: The method was developed and validated using RP-HPLC-diode-array detection at 320 nm for accuracy, precision and limits of detection and was applied for quantification of it markers in five different extracts prepared in solvents with increasing polarity, using a gradient mobile phase 0.1% formic acid: Acetonitrile at a flow rate of 1 ml/min on reverse phase acclaim polar advantage II C18 column (3 μm, 3 × 150 mm) with 18 min separation time. RESULTS: The developed method provided satisfactory precision, and the accuracy of this method was in the range of 90.2% to 105.5%. All of 4 compounds showed good linearity at R2 > 0.999. CONCLUSION: The developed method is a simple, cost effective with shorter run time (18 min) in comparison to previous methods (30 min) and utilization of environmental-friendly solvents system. Therefore, this method has the potential to replace currently used methods in the routine standardization work of O. stamineus extracts, raw materials and its commercial products. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4285645/ /pubmed/25598631 http://dx.doi.org/10.4103/0974-8490.147195 Text en Copyright: © Pharmacognosy Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Saidan, Noor Hafizoh Aisha, Abdalrahim F.A. Hamil, Mohd Shahrul Ridzuan Majid, Amin Malik Shah Abdul Ismail, Zhari A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts |
title | A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts |
title_full | A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts |
title_fullStr | A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts |
title_full_unstemmed | A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts |
title_short | A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts |
title_sort | novel reverse phase high-performance liquid chromatography method for standardization of orthosiphon stamineus leaf extracts |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4285645/ https://www.ncbi.nlm.nih.gov/pubmed/25598631 http://dx.doi.org/10.4103/0974-8490.147195 |
work_keys_str_mv | AT saidannoorhafizoh anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT aishaabdalrahimfa anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT hamilmohdshahrulridzuan anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT majidaminmalikshahabdul anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT ismailzhari anovelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT saidannoorhafizoh novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT aishaabdalrahimfa novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT hamilmohdshahrulridzuan novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT majidaminmalikshahabdul novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts AT ismailzhari novelreversephasehighperformanceliquidchromatographymethodforstandardizationoforthosiphonstamineusleafextracts |