Cargando…

Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats

Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the v...

Descripción completa

Detalles Bibliográficos
Autores principales: Le, Jung-Min, Han, Young-Hwan, Choi, Su-Jeong, Park, Ju-seong, Jang, Jeong-Jun, Bae, Re-Ji-Na, Lee, Mi Ju, Kim, Myoung Jun, Lee, Yong-Hoon, Kim, Duyeol, Lee, Hye-Young, Park, Sun-Hee, Park, Cheol-Beom, Kang, Jin Seok, Kang, Jong-Koo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society Of Toxicology 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4289932/
https://www.ncbi.nlm.nih.gov/pubmed/25584151
http://dx.doi.org/10.5487/TR.2014.30.4.305
_version_ 1782352168365326336
author Le, Jung-Min
Han, Young-Hwan
Choi, Su-Jeong
Park, Ju-seong
Jang, Jeong-Jun
Bae, Re-Ji-Na
Lee, Mi Ju
Kim, Myoung Jun
Lee, Yong-Hoon
Kim, Duyeol
Lee, Hye-Young
Park, Sun-Hee
Park, Cheol-Beom
Kang, Jin Seok
Kang, Jong-Koo
author_facet Le, Jung-Min
Han, Young-Hwan
Choi, Su-Jeong
Park, Ju-seong
Jang, Jeong-Jun
Bae, Re-Ji-Na
Lee, Mi Ju
Kim, Myoung Jun
Lee, Yong-Hoon
Kim, Duyeol
Lee, Hye-Young
Park, Sun-Hee
Park, Cheol-Beom
Kang, Jin Seok
Kang, Jong-Koo
author_sort Le, Jung-Min
collection PubMed
description Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at 20℃, at 4℃, or at −70℃ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-β- D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at −70℃ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at 20℃ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at 4℃ (p < 0.01), at 20℃ (p < 0.05) and at 70℃ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.
format Online
Article
Text
id pubmed-4289932
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Society Of Toxicology
record_format MEDLINE/PubMed
spelling pubmed-42899322015-01-12 Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats Le, Jung-Min Han, Young-Hwan Choi, Su-Jeong Park, Ju-seong Jang, Jeong-Jun Bae, Re-Ji-Na Lee, Mi Ju Kim, Myoung Jun Lee, Yong-Hoon Kim, Duyeol Lee, Hye-Young Park, Sun-Hee Park, Cheol-Beom Kang, Jin Seok Kang, Jong-Koo Toxicol Res Research-Article Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at 20℃, at 4℃, or at −70℃ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-β- D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at −70℃ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at 20℃ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at 4℃ (p < 0.01), at 20℃ (p < 0.05) and at 70℃ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers. The Korean Society Of Toxicology 2014-12 /pmc/articles/PMC4289932/ /pubmed/25584151 http://dx.doi.org/10.5487/TR.2014.30.4.305 Text en Copyright © 2014, The Korean Society Of Toxicology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research-Article
Le, Jung-Min
Han, Young-Hwan
Choi, Su-Jeong
Park, Ju-seong
Jang, Jeong-Jun
Bae, Re-Ji-Na
Lee, Mi Ju
Kim, Myoung Jun
Lee, Yong-Hoon
Kim, Duyeol
Lee, Hye-Young
Park, Sun-Hee
Park, Cheol-Beom
Kang, Jin Seok
Kang, Jong-Koo
Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats
title Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats
title_full Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats
title_fullStr Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats
title_full_unstemmed Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats
title_short Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats
title_sort variation of nephrotoxicity biomarkers by urinary storage condition in rats
topic Research-Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4289932/
https://www.ncbi.nlm.nih.gov/pubmed/25584151
http://dx.doi.org/10.5487/TR.2014.30.4.305
work_keys_str_mv AT lejungmin variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT hanyounghwan variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT choisujeong variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT parkjuseong variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT jangjeongjun variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT baerejina variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT leemiju variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT kimmyoungjun variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT leeyonghoon variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT kimduyeol variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT leehyeyoung variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT parksunhee variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT parkcheolbeom variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT kangjinseok variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats
AT kangjongkoo variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats