Cargando…
Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats
Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the v...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society Of Toxicology
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4289932/ https://www.ncbi.nlm.nih.gov/pubmed/25584151 http://dx.doi.org/10.5487/TR.2014.30.4.305 |
_version_ | 1782352168365326336 |
---|---|
author | Le, Jung-Min Han, Young-Hwan Choi, Su-Jeong Park, Ju-seong Jang, Jeong-Jun Bae, Re-Ji-Na Lee, Mi Ju Kim, Myoung Jun Lee, Yong-Hoon Kim, Duyeol Lee, Hye-Young Park, Sun-Hee Park, Cheol-Beom Kang, Jin Seok Kang, Jong-Koo |
author_facet | Le, Jung-Min Han, Young-Hwan Choi, Su-Jeong Park, Ju-seong Jang, Jeong-Jun Bae, Re-Ji-Na Lee, Mi Ju Kim, Myoung Jun Lee, Yong-Hoon Kim, Duyeol Lee, Hye-Young Park, Sun-Hee Park, Cheol-Beom Kang, Jin Seok Kang, Jong-Koo |
author_sort | Le, Jung-Min |
collection | PubMed |
description | Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at 20℃, at 4℃, or at −70℃ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-β- D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at −70℃ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at 20℃ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at 4℃ (p < 0.01), at 20℃ (p < 0.05) and at 70℃ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers. |
format | Online Article Text |
id | pubmed-4289932 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Society Of Toxicology |
record_format | MEDLINE/PubMed |
spelling | pubmed-42899322015-01-12 Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats Le, Jung-Min Han, Young-Hwan Choi, Su-Jeong Park, Ju-seong Jang, Jeong-Jun Bae, Re-Ji-Na Lee, Mi Ju Kim, Myoung Jun Lee, Yong-Hoon Kim, Duyeol Lee, Hye-Young Park, Sun-Hee Park, Cheol-Beom Kang, Jin Seok Kang, Jong-Koo Toxicol Res Research-Article Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at 20℃, at 4℃, or at −70℃ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-β- D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at −70℃ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at 20℃ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at 4℃ (p < 0.01), at 20℃ (p < 0.05) and at 70℃ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers. The Korean Society Of Toxicology 2014-12 /pmc/articles/PMC4289932/ /pubmed/25584151 http://dx.doi.org/10.5487/TR.2014.30.4.305 Text en Copyright © 2014, The Korean Society Of Toxicology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research-Article Le, Jung-Min Han, Young-Hwan Choi, Su-Jeong Park, Ju-seong Jang, Jeong-Jun Bae, Re-Ji-Na Lee, Mi Ju Kim, Myoung Jun Lee, Yong-Hoon Kim, Duyeol Lee, Hye-Young Park, Sun-Hee Park, Cheol-Beom Kang, Jin Seok Kang, Jong-Koo Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats |
title | Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats |
title_full | Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats |
title_fullStr | Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats |
title_full_unstemmed | Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats |
title_short | Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats |
title_sort | variation of nephrotoxicity biomarkers by urinary storage condition in rats |
topic | Research-Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4289932/ https://www.ncbi.nlm.nih.gov/pubmed/25584151 http://dx.doi.org/10.5487/TR.2014.30.4.305 |
work_keys_str_mv | AT lejungmin variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT hanyounghwan variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT choisujeong variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT parkjuseong variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT jangjeongjun variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT baerejina variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT leemiju variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT kimmyoungjun variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT leeyonghoon variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT kimduyeol variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT leehyeyoung variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT parksunhee variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT parkcheolbeom variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT kangjinseok variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats AT kangjongkoo variationofnephrotoxicitybiomarkersbyurinarystorageconditioninrats |