Cargando…

The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures

OBJECTIVES: The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments. MATERIALS...

Descripción completa

Detalles Bibliográficos
Autores principales: Tabatabaian, Farhad, Saboury, Abolfazl, Sobhani, Zahra Sadat, Petropoulos, Vicki C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4290769/
https://www.ncbi.nlm.nih.gov/pubmed/25628676
_version_ 1782352299088150528
author Tabatabaian, Farhad
Saboury, Abolfazl
Sobhani, Zahra Sadat
Petropoulos, Vicki C
author_facet Tabatabaian, Farhad
Saboury, Abolfazl
Sobhani, Zahra Sadat
Petropoulos, Vicki C
author_sort Tabatabaian, Farhad
collection PubMed
description OBJECTIVES: The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments. MATERIALS AND METHODS: An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A framework simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment housings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertical, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey’s HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance. RESULTS: Peak loads for the anterior-posteriorly directed dislodging forces were significantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05). CONCLUSION: Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior-posterior resistance.
format Online
Article
Text
id pubmed-4290769
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-42907692015-01-27 The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures Tabatabaian, Farhad Saboury, Abolfazl Sobhani, Zahra Sadat Petropoulos, Vicki C J Dent (Tehran) Original Article OBJECTIVES: The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments. MATERIALS AND METHODS: An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A framework simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment housings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertical, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey’s HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance. RESULTS: Peak loads for the anterior-posteriorly directed dislodging forces were significantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05). CONCLUSION: Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior-posterior resistance. Tehran University of Medical Sciences 2014-09 2014-09-30 /pmc/articles/PMC4290769/ /pubmed/25628676 Text en Copyright © Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Tabatabaian, Farhad
Saboury, Abolfazl
Sobhani, Zahra Sadat
Petropoulos, Vicki C
The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
title The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
title_full The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
title_fullStr The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
title_full_unstemmed The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
title_short The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
title_sort effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4290769/
https://www.ncbi.nlm.nih.gov/pubmed/25628676
work_keys_str_mv AT tabatabaianfarhad theeffectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures
AT sabouryabolfazl theeffectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures
AT sobhanizahrasadat theeffectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures
AT petropoulosvickic theeffectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures
AT tabatabaianfarhad effectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures
AT sabouryabolfazl effectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures
AT sobhanizahrasadat effectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures
AT petropoulosvickic effectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures