Cargando…
The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
OBJECTIVES: The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments. MATERIALS...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tehran University of Medical Sciences
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4290769/ https://www.ncbi.nlm.nih.gov/pubmed/25628676 |
_version_ | 1782352299088150528 |
---|---|
author | Tabatabaian, Farhad Saboury, Abolfazl Sobhani, Zahra Sadat Petropoulos, Vicki C |
author_facet | Tabatabaian, Farhad Saboury, Abolfazl Sobhani, Zahra Sadat Petropoulos, Vicki C |
author_sort | Tabatabaian, Farhad |
collection | PubMed |
description | OBJECTIVES: The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments. MATERIALS AND METHODS: An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A framework simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment housings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertical, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey’s HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance. RESULTS: Peak loads for the anterior-posteriorly directed dislodging forces were significantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05). CONCLUSION: Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior-posterior resistance. |
format | Online Article Text |
id | pubmed-4290769 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Tehran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-42907692015-01-27 The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures Tabatabaian, Farhad Saboury, Abolfazl Sobhani, Zahra Sadat Petropoulos, Vicki C J Dent (Tehran) Original Article OBJECTIVES: The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments. MATERIALS AND METHODS: An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A framework simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment housings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertical, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey’s HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance. RESULTS: Peak loads for the anterior-posteriorly directed dislodging forces were significantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05). CONCLUSION: Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior-posterior resistance. Tehran University of Medical Sciences 2014-09 2014-09-30 /pmc/articles/PMC4290769/ /pubmed/25628676 Text en Copyright © Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Tabatabaian, Farhad Saboury, Abolfazl Sobhani, Zahra Sadat Petropoulos, Vicki C The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures |
title | The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures |
title_full | The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures |
title_fullStr | The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures |
title_full_unstemmed | The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures |
title_short | The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures |
title_sort | effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4290769/ https://www.ncbi.nlm.nih.gov/pubmed/25628676 |
work_keys_str_mv | AT tabatabaianfarhad theeffectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures AT sabouryabolfazl theeffectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures AT sobhanizahrasadat theeffectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures AT petropoulosvickic theeffectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures AT tabatabaianfarhad effectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures AT sabouryabolfazl effectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures AT sobhanizahrasadat effectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures AT petropoulosvickic effectofinterimplantdistanceonretentionandresistancetodislodgingforcesformandibularimplanttissuesupportedoverdentures |