Cargando…
Effect of Pre-heating on Microtensile Bond Strength of Composite Resin to Dentin
OBJECTIVE: Direct composite resin restorations are widely used and the impact of different storage temperatures on composites is not well understood. The purpose of this study was to evaluate the microtensile bond strength of composite to dentin after different pre-curing temperatures. MATERIALS AND...
Autores principales: | Davari, Abdolrahim, Daneshkazemi, Alireza, Behniafar, Behnaz, Sheshmani, Mahsan |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tehran University of Medical Sciences
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4290777/ https://www.ncbi.nlm.nih.gov/pubmed/25628684 |
Ejemplares similares
-
Effects of Thermal and Mechanical Load Cycling on the Dentin Microtensile Bond Strength of Single Bond-2
por: Daneshkazemi, Alireza, et al.
Publicado: (2015) -
Evaluating Resin-Dentin Bond by Microtensile Bond Strength Test: Effects of Various Resin Composites and Placement Techniques
por: Moosavi, Horieh, et al.
Publicado: (2015) -
Microtensile Bond Strength Evaluation of Composite Resin to Discolored Dentin After Amalgam Removal
por: Mandava, Jyothi, et al.
Publicado: (2020) -
Effect of preheating of low shrinking resin composite on intrapulpal temperature and microtensile bond strength to dentin
por: El-Deeb, Heba A., et al.
Publicado: (2015) -
Effect of different adhesive strategies on the microtensile bond strength of dentin to indirect resin-based composite
por: Pinto, Guilherme, et al.
Publicado: (2020)