Cargando…

Particle Size Distributions of Particulate Emissions from the Ferroalloy Industry Evaluated by Electrical Low Pressure Impactor (ELPI)

The present article presents a comprehensive evaluation of the potential use of an Electrical Low Pressure Impactor (ELPI) in the ferroalloy industry with respect to indoor air quality and fugitive emission control. The ELPI was used to assess particulate emission properties, particularly of the fin...

Descripción completa

Detalles Bibliográficos
Autores principales: Kero, Ida, Naess, Mari K., Tranell, Gabriella
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4292228/
https://www.ncbi.nlm.nih.gov/pubmed/25380385
http://dx.doi.org/10.1080/15459624.2014.935783
_version_ 1782352462984773632
author Kero, Ida
Naess, Mari K.
Tranell, Gabriella
author_facet Kero, Ida
Naess, Mari K.
Tranell, Gabriella
author_sort Kero, Ida
collection PubMed
description The present article presents a comprehensive evaluation of the potential use of an Electrical Low Pressure Impactor (ELPI) in the ferroalloy industry with respect to indoor air quality and fugitive emission control. The ELPI was used to assess particulate emission properties, particularly of the fine particles (D(p) ≤ 1 μm), which in turn may enable more satisfactory risk assessments for the indoor working conditions in the ferroalloy industry. An ELPI has been applied to characterize the fume in two different ferroalloy plants, one producing silicomanganese (SiMn) alloys and one producing ferrosilicon (FeSi) alloys. The impactor classifies the particles according to their aerodynamic diameter and gives real-time particle size distributions (PSD). The PSD based on both number and mass concentrations are shown and compared. Collected particles have also been analyzed by transmission and scanning electron microscopy with energy dispersive spectroscopy. From the ELPI classification, particle size distributions in the range 7 nm – 10 μm have been established for industrial SiMn and FeSi fumes. Due to the extremely low masses of the ultrafine particles, the number and mass concentration PSD are significantly different. The average aerodynamic diameters for the FeSi and the SiMn fume particles were 0.17 and 0.10 μm, respectively. Based on this work, the ELPI is identified as a valuable tool for the evaluation of airborne particulate matter in the indoor air of metallurgical production sites. The method is well suited for real-time assessment of morphology (particle shape), particle size, and particle size distribution of aerosols.
format Online
Article
Text
id pubmed-4292228
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-42922282015-01-26 Particle Size Distributions of Particulate Emissions from the Ferroalloy Industry Evaluated by Electrical Low Pressure Impactor (ELPI) Kero, Ida Naess, Mari K. Tranell, Gabriella J Occup Environ Hyg Original Articles The present article presents a comprehensive evaluation of the potential use of an Electrical Low Pressure Impactor (ELPI) in the ferroalloy industry with respect to indoor air quality and fugitive emission control. The ELPI was used to assess particulate emission properties, particularly of the fine particles (D(p) ≤ 1 μm), which in turn may enable more satisfactory risk assessments for the indoor working conditions in the ferroalloy industry. An ELPI has been applied to characterize the fume in two different ferroalloy plants, one producing silicomanganese (SiMn) alloys and one producing ferrosilicon (FeSi) alloys. The impactor classifies the particles according to their aerodynamic diameter and gives real-time particle size distributions (PSD). The PSD based on both number and mass concentrations are shown and compared. Collected particles have also been analyzed by transmission and scanning electron microscopy with energy dispersive spectroscopy. From the ELPI classification, particle size distributions in the range 7 nm – 10 μm have been established for industrial SiMn and FeSi fumes. Due to the extremely low masses of the ultrafine particles, the number and mass concentration PSD are significantly different. The average aerodynamic diameters for the FeSi and the SiMn fume particles were 0.17 and 0.10 μm, respectively. Based on this work, the ELPI is identified as a valuable tool for the evaluation of airborne particulate matter in the indoor air of metallurgical production sites. The method is well suited for real-time assessment of morphology (particle shape), particle size, and particle size distribution of aerosols. Taylor & Francis 2015-01-02 2014-11-07 /pmc/articles/PMC4292228/ /pubmed/25380385 http://dx.doi.org/10.1080/15459624.2014.935783 Text en ©Ida Kero, Mari Ness, Gabriella Tranell. Published with license by Taylor & Francis This is an Open Access article. Non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly attributed, cited, and is not altered, transformed, or built upon in any way, is permitted. The moral rights of the named author(s) have been asserted.
spellingShingle Original Articles
Kero, Ida
Naess, Mari K.
Tranell, Gabriella
Particle Size Distributions of Particulate Emissions from the Ferroalloy Industry Evaluated by Electrical Low Pressure Impactor (ELPI)
title Particle Size Distributions of Particulate Emissions from the Ferroalloy Industry Evaluated by Electrical Low Pressure Impactor (ELPI)
title_full Particle Size Distributions of Particulate Emissions from the Ferroalloy Industry Evaluated by Electrical Low Pressure Impactor (ELPI)
title_fullStr Particle Size Distributions of Particulate Emissions from the Ferroalloy Industry Evaluated by Electrical Low Pressure Impactor (ELPI)
title_full_unstemmed Particle Size Distributions of Particulate Emissions from the Ferroalloy Industry Evaluated by Electrical Low Pressure Impactor (ELPI)
title_short Particle Size Distributions of Particulate Emissions from the Ferroalloy Industry Evaluated by Electrical Low Pressure Impactor (ELPI)
title_sort particle size distributions of particulate emissions from the ferroalloy industry evaluated by electrical low pressure impactor (elpi)
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4292228/
https://www.ncbi.nlm.nih.gov/pubmed/25380385
http://dx.doi.org/10.1080/15459624.2014.935783
work_keys_str_mv AT keroida particlesizedistributionsofparticulateemissionsfromtheferroalloyindustryevaluatedbyelectricallowpressureimpactorelpi
AT naessmarik particlesizedistributionsofparticulateemissionsfromtheferroalloyindustryevaluatedbyelectricallowpressureimpactorelpi
AT tranellgabriella particlesizedistributionsofparticulateemissionsfromtheferroalloyindustryevaluatedbyelectricallowpressureimpactorelpi