Cargando…

A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser

BACKGROUND: We report a case of Ex-PRESS miniature glaucoma shunt obstruction resulting from progressive iris synechial formation after transient anterior chamber shallowing. CASE PRESENTATION: A 68-year-old woman with pseudoexfoliation glaucoma in her right eye underwent filtration surgery with imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Tanito, Masaki, Sano, Ichiya, Ohira, Akihiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4293806/
https://www.ncbi.nlm.nih.gov/pubmed/25571925
http://dx.doi.org/10.1186/1471-2415-15-2
_version_ 1782352649176219648
author Tanito, Masaki
Sano, Ichiya
Ohira, Akihiro
author_facet Tanito, Masaki
Sano, Ichiya
Ohira, Akihiro
author_sort Tanito, Masaki
collection PubMed
description BACKGROUND: We report a case of Ex-PRESS miniature glaucoma shunt obstruction resulting from progressive iris synechial formation after transient anterior chamber shallowing. CASE PRESENTATION: A 68-year-old woman with pseudoexfoliation glaucoma in her right eye underwent filtration surgery with implantation of the Ex-PPESS shunt (model P-50, Alcon Japan, Tokyo, Japan) in combination with intra-surgical 0.04% mitomycin C use. After the anterior chamber injection of viscoelastic material and 100% sulfur hexafluoride gas for treatment of early postoperative over filtration, the intraocular pressure (IOP) was controlled between 9 and 12 mmHg. On postoperative day 121, gonioscopy showed that synechial formation around the shunt obstructed the axial port leaving the relief port opened. On postoperative day 274, the intraocular pressure increased to 40 mmHg and synechiae obstructed both the axial and relief ports. Dispersion of iris tissue by neodymium:yttrium-aluminium-garnet (Nd:YAG) laser (2 mJ, one shot to each port) opened both ports and immediately lowered the IOP, leaving peripheral anterior synechiae around the shunt. Up to postoperative day 400, the IOP was controlled between 13 and 15 mmHg, and the cystic bleb was maintained. CONCLUSION: The synechiae formed gradually extends around the shunt’s shaft and can result in later external obstruction of the relief port. The current case requires further follow-up since synechiae remaining around the shaft can cause future obstruction. We emphasize the fact that, if the iris synechiae to the shunt once formed, it can progress and obstruct the shunt ports later.
format Online
Article
Text
id pubmed-4293806
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42938062015-01-15 A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser Tanito, Masaki Sano, Ichiya Ohira, Akihiro BMC Ophthalmol Case Report BACKGROUND: We report a case of Ex-PRESS miniature glaucoma shunt obstruction resulting from progressive iris synechial formation after transient anterior chamber shallowing. CASE PRESENTATION: A 68-year-old woman with pseudoexfoliation glaucoma in her right eye underwent filtration surgery with implantation of the Ex-PPESS shunt (model P-50, Alcon Japan, Tokyo, Japan) in combination with intra-surgical 0.04% mitomycin C use. After the anterior chamber injection of viscoelastic material and 100% sulfur hexafluoride gas for treatment of early postoperative over filtration, the intraocular pressure (IOP) was controlled between 9 and 12 mmHg. On postoperative day 121, gonioscopy showed that synechial formation around the shunt obstructed the axial port leaving the relief port opened. On postoperative day 274, the intraocular pressure increased to 40 mmHg and synechiae obstructed both the axial and relief ports. Dispersion of iris tissue by neodymium:yttrium-aluminium-garnet (Nd:YAG) laser (2 mJ, one shot to each port) opened both ports and immediately lowered the IOP, leaving peripheral anterior synechiae around the shunt. Up to postoperative day 400, the IOP was controlled between 13 and 15 mmHg, and the cystic bleb was maintained. CONCLUSION: The synechiae formed gradually extends around the shunt’s shaft and can result in later external obstruction of the relief port. The current case requires further follow-up since synechiae remaining around the shaft can cause future obstruction. We emphasize the fact that, if the iris synechiae to the shunt once formed, it can progress and obstruct the shunt ports later. BioMed Central 2015-01-08 /pmc/articles/PMC4293806/ /pubmed/25571925 http://dx.doi.org/10.1186/1471-2415-15-2 Text en © Tanito et al.; licensee BioMed Central. 2015 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Case Report
Tanito, Masaki
Sano, Ichiya
Ohira, Akihiro
A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser
title A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser
title_full A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser
title_fullStr A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser
title_full_unstemmed A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser
title_short A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser
title_sort case report of progressive obstruction of ex-press miniature glaucoma shunt after transient flat anterior chamber and treatment using nd:yag laser
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4293806/
https://www.ncbi.nlm.nih.gov/pubmed/25571925
http://dx.doi.org/10.1186/1471-2415-15-2
work_keys_str_mv AT tanitomasaki acasereportofprogressiveobstructionofexpressminiatureglaucomashuntaftertransientflatanteriorchamberandtreatmentusingndyaglaser
AT sanoichiya acasereportofprogressiveobstructionofexpressminiatureglaucomashuntaftertransientflatanteriorchamberandtreatmentusingndyaglaser
AT ohiraakihiro acasereportofprogressiveobstructionofexpressminiatureglaucomashuntaftertransientflatanteriorchamberandtreatmentusingndyaglaser
AT tanitomasaki casereportofprogressiveobstructionofexpressminiatureglaucomashuntaftertransientflatanteriorchamberandtreatmentusingndyaglaser
AT sanoichiya casereportofprogressiveobstructionofexpressminiatureglaucomashuntaftertransientflatanteriorchamberandtreatmentusingndyaglaser
AT ohiraakihiro casereportofprogressiveobstructionofexpressminiatureglaucomashuntaftertransientflatanteriorchamberandtreatmentusingndyaglaser