Cargando…

Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry

A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department o...

Descripción completa

Detalles Bibliográficos
Autores principales: West, Caroline E., Rhodes, Blaine N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4295589/
https://www.ncbi.nlm.nih.gov/pubmed/25614740
http://dx.doi.org/10.1155/2014/247316
_version_ 1782352871190167552
author West, Caroline E.
Rhodes, Blaine N.
author_facet West, Caroline E.
Rhodes, Blaine N.
author_sort West, Caroline E.
collection PubMed
description A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department of Health, Public Health Laboratories (PHL). 50 µL of urine was mixed with a 1 : 1 acetonitrile/water solution containing deuterated creatinine as the internal standard and then analyzed by LC/MS/MS. Utilizing electrospray ionization (ESI) in positive mode, the transition ions for creatinine and creatinine-d(3) were determined to be 114.0 to 44.1 (quantifier), 114.0 to 86.1 (qualifier), and 117.0 to 47.1 (creatinine-d(3)). The retention time for creatinine was 0.85 minutes. The linear calibration range was 20–4000 mg/L, with a limit of detection at 1.77 mg/L and a limit of quantitation at 5.91 mg/L. LC/MS/MS and the colorimetric Jaffé reaction were associated significantly (Pearson r = 0.9898 and R (2) = 0.9797, ρ ≤ 0.0001). The LC/MS/MS method developed at the PHL to determine creatinine in the spot urine samples had shorter retention times, and was more sensitive, reliable, reproducible, and safer than other LC/MS/MS or commercial methods such as the Jaffé reaction or modified versions thereof.
format Online
Article
Text
id pubmed-4295589
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-42955892015-01-22 Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry West, Caroline E. Rhodes, Blaine N. Int J Anal Chem Research Article A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department of Health, Public Health Laboratories (PHL). 50 µL of urine was mixed with a 1 : 1 acetonitrile/water solution containing deuterated creatinine as the internal standard and then analyzed by LC/MS/MS. Utilizing electrospray ionization (ESI) in positive mode, the transition ions for creatinine and creatinine-d(3) were determined to be 114.0 to 44.1 (quantifier), 114.0 to 86.1 (qualifier), and 117.0 to 47.1 (creatinine-d(3)). The retention time for creatinine was 0.85 minutes. The linear calibration range was 20–4000 mg/L, with a limit of detection at 1.77 mg/L and a limit of quantitation at 5.91 mg/L. LC/MS/MS and the colorimetric Jaffé reaction were associated significantly (Pearson r = 0.9898 and R (2) = 0.9797, ρ ≤ 0.0001). The LC/MS/MS method developed at the PHL to determine creatinine in the spot urine samples had shorter retention times, and was more sensitive, reliable, reproducible, and safer than other LC/MS/MS or commercial methods such as the Jaffé reaction or modified versions thereof. Hindawi Publishing Corporation 2014 2014-12-31 /pmc/articles/PMC4295589/ /pubmed/25614740 http://dx.doi.org/10.1155/2014/247316 Text en Copyright © 2014 C. E. West and B. N. Rhodes. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
West, Caroline E.
Rhodes, Blaine N.
Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry
title Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry
title_full Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry
title_fullStr Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry
title_full_unstemmed Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry
title_short Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry
title_sort determination of urinary creatinine in washington state residents via liquid chromatography/tandem mass spectrometry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4295589/
https://www.ncbi.nlm.nih.gov/pubmed/25614740
http://dx.doi.org/10.1155/2014/247316
work_keys_str_mv AT westcarolinee determinationofurinarycreatinineinwashingtonstateresidentsvialiquidchromatographytandemmassspectrometry
AT rhodesblainen determinationofurinarycreatinineinwashingtonstateresidentsvialiquidchromatographytandemmassspectrometry