Cargando…

Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering

OBJECTIVE: To assess the effect of chest circumference-adapted scanning protocol on radiation exposure and image quality in patients undergoing prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). MATERIALS AND METHODS: One hundred-eighty-five consecutive patients, who had u...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Chenying, Wang, Zufei, Ji, Jiansong, Wang, Hailin, Hu, Xianghua, Chen, Chunmiao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4296260/
https://www.ncbi.nlm.nih.gov/pubmed/25598671
http://dx.doi.org/10.3348/kjr.2015.16.1.13
_version_ 1782352945396842496
author Lu, Chenying
Wang, Zufei
Ji, Jiansong
Wang, Hailin
Hu, Xianghua
Chen, Chunmiao
author_facet Lu, Chenying
Wang, Zufei
Ji, Jiansong
Wang, Hailin
Hu, Xianghua
Chen, Chunmiao
author_sort Lu, Chenying
collection PubMed
description OBJECTIVE: To assess the effect of chest circumference-adapted scanning protocol on radiation exposure and image quality in patients undergoing prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). MATERIALS AND METHODS: One hundred-eighty-five consecutive patients, who had undergone prospective ECG triggering CCTA with a 128-slice CT, were included in the present study. Nipple-level chest circumference, body weight and height were measured before CT examinations. Patients were divided into four groups based on kV/ref·mAs = 100/200, 100/250, 120/200, and 120/250, when patient's chest circumference was ≤ 85.0 (n = 56), 85.0-90.0 (n = 53), 90.0-95.0 (n = 44), and > 95.0 (n = 32), respectively. Image quality per-segment was independently assessed by two experienced observers. Image noise and attenuation were also measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The effective radiation dose was calculated using CT dose volume index and the dose-length product. RESULTS: A significant correlation was observed between patients' chest circumference and body mass index (r = 0.762, p < 0.001). Chest circumference ranged from 74 to 105 cm, and the mean effective radiation dose was 1.9-3.8 mSv. Diagnostic image quality was obtained in 98.5% (2440/2478) of all evaluated coronary segments without any significant differences among the four groups (p = 0.650). No significant difference in image noise was observed among the four groups (p = 0.439), thus supporting the validity of the chest circumference-adapted scanning protocol. However, vessel attenuation, SNR and CNR were significantly higher in the 100 kV groups than in the 120 kV groups (p < 0.05). CONCLUSION: A measure of chest circumference can be used to adapt tube voltage and current for individualized radiation dose control, with resultant similar image noise and sustained diagnostic image quality.
format Online
Article
Text
id pubmed-4296260
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-42962602015-01-16 Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering Lu, Chenying Wang, Zufei Ji, Jiansong Wang, Hailin Hu, Xianghua Chen, Chunmiao Korean J Radiol Cardiovascular Imaging OBJECTIVE: To assess the effect of chest circumference-adapted scanning protocol on radiation exposure and image quality in patients undergoing prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). MATERIALS AND METHODS: One hundred-eighty-five consecutive patients, who had undergone prospective ECG triggering CCTA with a 128-slice CT, were included in the present study. Nipple-level chest circumference, body weight and height were measured before CT examinations. Patients were divided into four groups based on kV/ref·mAs = 100/200, 100/250, 120/200, and 120/250, when patient's chest circumference was ≤ 85.0 (n = 56), 85.0-90.0 (n = 53), 90.0-95.0 (n = 44), and > 95.0 (n = 32), respectively. Image quality per-segment was independently assessed by two experienced observers. Image noise and attenuation were also measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The effective radiation dose was calculated using CT dose volume index and the dose-length product. RESULTS: A significant correlation was observed between patients' chest circumference and body mass index (r = 0.762, p < 0.001). Chest circumference ranged from 74 to 105 cm, and the mean effective radiation dose was 1.9-3.8 mSv. Diagnostic image quality was obtained in 98.5% (2440/2478) of all evaluated coronary segments without any significant differences among the four groups (p = 0.650). No significant difference in image noise was observed among the four groups (p = 0.439), thus supporting the validity of the chest circumference-adapted scanning protocol. However, vessel attenuation, SNR and CNR were significantly higher in the 100 kV groups than in the 120 kV groups (p < 0.05). CONCLUSION: A measure of chest circumference can be used to adapt tube voltage and current for individualized radiation dose control, with resultant similar image noise and sustained diagnostic image quality. The Korean Society of Radiology 2015 2015-01-09 /pmc/articles/PMC4296260/ /pubmed/25598671 http://dx.doi.org/10.3348/kjr.2015.16.1.13 Text en Copyright © 2015 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Lu, Chenying
Wang, Zufei
Ji, Jiansong
Wang, Hailin
Hu, Xianghua
Chen, Chunmiao
Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering
title Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering
title_full Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering
title_fullStr Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering
title_full_unstemmed Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering
title_short Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering
title_sort evaluation of a chest circumference-adapted protocol for low-dose 128-slice coronary ct angiography with prospective electrocardiogram triggering
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4296260/
https://www.ncbi.nlm.nih.gov/pubmed/25598671
http://dx.doi.org/10.3348/kjr.2015.16.1.13
work_keys_str_mv AT luchenying evaluationofachestcircumferenceadaptedprotocolforlowdose128slicecoronaryctangiographywithprospectiveelectrocardiogramtriggering
AT wangzufei evaluationofachestcircumferenceadaptedprotocolforlowdose128slicecoronaryctangiographywithprospectiveelectrocardiogramtriggering
AT jijiansong evaluationofachestcircumferenceadaptedprotocolforlowdose128slicecoronaryctangiographywithprospectiveelectrocardiogramtriggering
AT wanghailin evaluationofachestcircumferenceadaptedprotocolforlowdose128slicecoronaryctangiographywithprospectiveelectrocardiogramtriggering
AT huxianghua evaluationofachestcircumferenceadaptedprotocolforlowdose128slicecoronaryctangiographywithprospectiveelectrocardiogramtriggering
AT chenchunmiao evaluationofachestcircumferenceadaptedprotocolforlowdose128slicecoronaryctangiographywithprospectiveelectrocardiogramtriggering