Cargando…

Corrosion behavior of self-ligating and conventional metal brackets

OBJECTIVE: To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. METHODS: Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek) and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek) metal brackets from three manufacturers (...

Descripción completa

Detalles Bibliográficos
Autores principales: Maia, Lúcio Henrique Esmeraldo Gurgel, Lopes Filho, Hibernon, Ruellas, Antônio Carlos de Oliveira, Araújo, Mônica Tirre de Souza, Vaitsman, Delmo Santiago
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dental Press International 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4296607/
https://www.ncbi.nlm.nih.gov/pubmed/24945521
http://dx.doi.org/10.1590/2176-9451.19.2.108-114.oar
Descripción
Sumario:OBJECTIVE: To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. METHODS: Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek) and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek) metal brackets from three manufacturers (n = 150) were submitted to aging process in 0.9% NaCl solution at a constant temperature of 37 ± 1ºC for 21 days. The content of nickel, chromium and iron ions in the solution collected at intervals of 7, 14 and 21 days was quantified by atomic absorption spectrophotometry. After the aging process, the brackets were analyzed by scanning electron microscopy (SEM) under 22X and 1,000X magnifications. RESULTS: Comparison of metal release in self-ligating and conventional brackets from the same manufacturer proved that the SCs group released more nickel (p < 0.05) than the GN group after 7 and 14 days, but less chromium (p < 0.05) after 14 days and less iron (p < 0.05) at the three experimental time intervals. The INs group released less iron (p < 0.05) than the GE group after 7 days and less nickel, chromium and iron (p < 0.05) after 14 and 21 days. The ECs group released more nickel, chromium and iron (p < 0.05) than the VE group after 14 days, but released less nickel and chromium (p < 0.05) after 7 days and less chromium and iron (p < 0.05) after 21 days. The SEM analysis revealed alterations on surface topography of conventional and self-ligating brackets. CONCLUSIONS: The aging process in self-ligating brackets was not greater than in conventional brackets from the same manufacturer. The null hypothesis was accepted.